PEPPEL FUCHS BARRIER Specification

  • Rated Power
  • As per model, low power signal circuits
  • Output Type
  • Relay Output / Type N/O relay contact (varies by model)
  • Noise Level
  • Low signal interference (EMC-compliant)
  • Operating Temperature
  • -20C to +60C
  • Rated Current
  • 10 mA typ.
  • Current Range
  • 7 mA to 20 mA (typical input signal)
  • Power Supply
  • Powered via control circuit, 24 V DC
  • Cooling Method
  • Natural Air Cooling
  • Power Factor
  • Not applicable (signal devices)
  • Phase
  • Single Phase (signal line application)
  • Application
  • Hazardous Area, Intrinsically Safe Barriers, Signal Isolation
  • Features
  • DIN Rail Mountable, LED Indicator, Removable Terminals
  • Connector Type
  • Screw Terminal
  • Working Temperature
  • -20C to +60C
  • Output Current
  • < 50 mA (typical; varies by model)
  • Product Type
  • Intrinsic Safety Barrier
  • Output Power
  • Limited (for signal transmission)
  • Output Frequency
  • Signal frequency, suitable for analog/digital
  • Input Voltage
  • 24 V DC
  • Voltage Protection
  • Integrated Overvoltage Protection
  • Efficiency
  • High signal fidelity (typical for IS barriers)
  • Material
  • Plastic housing (industry-standard)
  • Line Regulation
  • Maintains signal integrity across voltage variance
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 150g
  • Enclosure Protection
  • IP20
  • Mounting Type
  • DIN Rail (35 mm) Mount
  • Isolation Voltage
  • Test Voltage 2.5 kV AC, Input/Output/Power
  • Safety Category
  • ATEX, IECEx Approved
  • Channel Type
  • Single or Dual Channel Available
  • Model Number
  • KFD2 Series (Typical)
  • Input Signal Type
  • Analog/DC
  • Response Time
  • < 10 ms
  • Dimensions
  • Approx. 20 x 115 x 110 mm
 
 

About PEPPEL FUCHS BARRIER



Unlock instant savings with the rare PEPPEL FUCHS BARRIER, Model KFD2 Series, a first-rate solution for hazardous area signal isolation. Designed for perfect integration on 35 mm DIN rails, it boasts ATEX and IECEx safety approvals and magnificent efficiency with high signal fidelity. Its IP20 enclosure and rapid <10 ms response time assure reliability. Featuring single or dual channel options, integrated overvoltage protection, and LED indicators, this lightweight (approx. 150g), EMC-compliant device ensures excellent line regulation and robust protection for industrial applications.

Optimized for Hazardous Areas and Intrinsic Safety

The PEPPEL FUCHS BARRIER excels in hazardous area applications, offering magnificent signal isolation and intrinsic safety for analog/DC inputs. Engineered for easy DIN rail mounting, it features removable terminals, LED indicators, and natural air cooling. Perfect for signal transmission in environments requiring IP20 protection, it caters to both single and dual-channel needs. The barriers precise response and low noise levels deliver reliability, making it ideal for process automation, safety circuits, and signal protection systems.


Certified Quality and Global Reach

This model enjoys a strong market value across international export markets, underpinned by prestigious certifications like ATEX and IECEx. Its valuation is enhanced by reliable transportation arrangements available throughout India and beyond. With easy payment terms tailored for a global clientele, the PEPPEL FUCHS BARRIER ensures convenient, secure acquisition for traders and suppliers. Outstanding compliance and regular testing reinforce trust and promote market growth, making it a highly regarded asset in industrial automation solutions.


FAQs of PEPPEL FUCHS BARRIER:


Q: How does the PEPPEL FUCHS BARRIER ensure safety in hazardous areas?

A: The barrier is ATEX and IECEx certified, offering intrinsic safety by isolating input signals and providing integrated overvoltage protection, making it suitable for explosive or hazardous environments.

Q: What types of input signals are compatible with the KFD2 Series barrier?

A: This device supports analog or DC input signals and maintains high signal fidelity for both analog and digital applications, accommodating a typical current range of 7 mA to 20 mA.

Q: When should you use a single or dual-channel barrier?

A: Choose a single channel for individual control loops, and opt for a dual-channel version when multiple circuits require isolation, maximizing installation space and efficiency.

Q: Where is the PEPPEL FUCHS BARRIER typically installed?

A: Designed for DIN Rail (35 mm) mounting, it is commonly installed inside industrial control panels in processing plants, refineries, or any hazardous area requiring signal isolation and safety.

Q: What are the benefits of integrated LED indicators and removable terminals?

A: LED indicators offer real-time status monitoring, while removable terminals allow for quick installation and maintenance, enhancing operational efficiency and reducing downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPERL + FUCHS Power Module KHD2-OT1/EX

PEPPERL + FUCHS Power Module KHD2-OT1/EX

Material : Polycarbonate (Housing)

Operating Temperature : 20C to +60C

Output Type : Other, Relay Output, Contact Output

Storage Temperature : 25C to +70C

Output Current : up to 0.42 A

Working Temperature : 20C to +60C

PEPPERL +  FUCHS BARRIER

PEPPERL + FUCHS BARRIER

Material : Plastic or aluminum enclosure

Operating Temperature : 20C to +60C

Output Type : Other, Isolated

Storage Temperature : 25C to +70C

Output Current : Max. 50 mA

Working Temperature : 20C to +60C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Material : Industrial Grade Plastic / Metal

Operating Temperature : 20C to +60C

Output Type : Other, Analog / Digital Signal Compatible

Storage Temperature : 25C to +70C

Output Current : Maximum 100 mA

Working Temperature : 20C to +60C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Material : Plastic housing

Operating Temperature : 20C to +60C

Output Type : Other, Signal output (safe area)

Storage Temperature : 25C to +70C

Output Current : Max 93 mA

Working Temperature : 20C to +60C