PEPPEL FUCHS BARRIER Specification

  • Phase
  • Single Phase
  • Current Range
  • 0100 mA
  • Features
  • DIN-rail mounting, LED status indicator, galvanic isolation
  • Working Temperature
  • -20C to +60C
  • Power Supply
  • 24 V DC typical
  • Connector Type
  • Screw terminals
  • Application
  • Hazardous area signal isolation
  • Output Current
  • Up to 100 mA (typical)
  • Operating Temperature
  • -20C to +60C
  • Output Type
  • Signal isolation
  • Cooling Method
  • Natural convection
  • Rated Current
  • Max. 100 mA
  • Product Type
  • Intrinsically Safe Barrier
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Reverse polarity and surge protection
  • Material
  • Plastic housing
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 120 g
  • Channel Type
  • Single channel
  • Dimensions
  • 114.5 mm x 20 mm x 124.5 mm
  • Response Time
  • < 10 ms
  • Safety Type
  • Intrinsic safety (explosion protection)
  • Degree of protection
  • IP20
  • Signal Type
  • Analog (4-20 mA or 1-5 V DC)
  • Model
  • KFD2-STC4-EX1
  • Mounting Type
  • DIN rail
  • Isolation Voltage
  • 250 V AC (input/output/power)
 
 

PEPPEL FUCHS BARRIER About



Introducing the brilliant PEPPEL FUCHS BARRIER Model: KFD2-STC4-EX1now at a significant price cut! Enjoy a masterful blend of radiant performance and robust protection for hazardous area signal isolation, complete with DIN rail mounting flexibility. This device features single channel signal isolation (analog: 4-20 mA or 1-5 V DC) with intrinsic safety, galvanic isolation, and lightning-fast response (<10 ms). Benefit from IP20 degree protection, reverse polarity and surge protection, and LED status indicators. With our markdown offer, get the best price from Indias trusted supplier and trader today!

Versatile Application Across Industrial Environments

The PEPPEL FUCHS BARRIER is expertly designed for hazardous area signal isolation, making it ideal for use in chemical plants, refineries, and process industries. Its surface application suits control panels and instrumentation cabinets, while DIN-rail mounting ensures effortless installation. Whether protecting signal integrity in power plant operations or facilitating safe communications in manufacturing sites, this device delivers dependable performance in demanding conditions.


Pragmatic Export Policy and Efficient Dispatch

Our Sample Policy for the PEPPEL FUCHS BARRIER is clear and customer-orientedsamples provided upon confirmation at the list price. Delivery time is swift after packing & dispatch, typically within a few days from order confirmation. We ship to major export markets across India and beyond, with freight arrangements tailored to your requirements. Robust packing ensures that your product arrives safely and ready for installation.


FAQs of PEPPEL FUCHS BARRIER:


Q: How does the PEPPEL FUCHS BARRIER ensure safety in hazardous environments?

A: The PEPPEL FUCHS BARRIER utilizes intrinsic safety mechanisms and galvanic isolation to prevent electrical faults in hazardous areas, minimizing the risk of explosions and protecting equipment.

Q: What are the primary plant applications for this barrier device?

A: This barrier is primarily used in industrial plants such as chemical processing facilities, refineries, and power stations requiring reliable analog signal isolation and explosion protection.

Q: When can I expect the delivery of my order after placing it?

A: Once the order and packing & dispatch details are confirmed, delivery typically occurs within a few days, ensuring prompt arrival for urgent operational requirements.

Q: Where should the PEPPEL FUCHS BARRIER be installed for optimal performance?

A: Install the barrier on a DIN rail inside control panels or instrumentation cabinets, ensuring access to screw terminals and adequate ventilation for effective natural convection cooling.

Q: What benefits does the LED status indicator provide for users?

A: The LED status indicator offers quick visual feedback on device operation, helping users monitor the systems health and identify issues without complex diagnostics.

Q: How does reverse polarity and surge protection enhance device longevity?

A: Reverse polarity and surge protection safeguards the barrier from electrical mishaps, prolonging its functional life and preventing damage due to incorrect wiring or voltage spikes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Input Voltage : 24V DC

Material : Polycarbonate housing

Product Type : Intrinsic Safety Barrier

Application : Hazardous area signal transmission, process automation

Power Supply : 24V DC (nom.)

Operating Temperature : 20C to +60C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Input Voltage : 24 V DC

Material : Polycarbonate Enclosure

Product Type : Intrinsic Safety Barrier

Application : Hazardous Area Signal Transmission

Power Supply : 24 V DC nominal

Operating Temperature : 20C to +60C

PEPPERL+FUCHS KFD2-ER-EX1.W.LB

PEPPERL+FUCHS KFD2-ER-EX1.W.LB

Input Voltage : 20 V DC to 35 V DC

Material : Polycarbonate enclosure

Product Type : 1channel relay module with relay contact output for hazardous areas

Application : Use in hazardous area signal isolation and relay switching, suitable for process automation

Power Supply : 24 V DC nominal

Operating Temperature : 20C to +60C

PEPPERL++FUCHS NCB50-FP-E2-C-P3-V1

PEPPERL++FUCHS NCB50-FP-E2-C-P3-V1

Input Voltage : 1060 V DC

Material : Plastic (Housing)

Product Type : Inductive Proximity Sensor

Application : Position sensing in automation and industrial applications

Power Supply : 1060 V DC

Operating Temperature : 25C to +70C



Back to top