PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

PEPPEL FUCHS BARRIER Specification

  • Working Temperature
  • -20C to +60C
  • Operating Temperature
  • -20C to +60C
  • Rated Current
  • Max. 100 mA
  • Phase
  • Single Phase
  • Output Type
  • Signal isolation
  • Output Current
  • Up to 100 mA (typical)
  • Power Supply
  • 24 V DC typical
  • Features
  • DIN-rail mounting, LED status indicator, galvanic isolation
  • Connector Type
  • Screw terminals
  • Application
  • Hazardous area signal isolation
  • Current Range
  • 0100 mA
  • Cooling Method
  • Natural convection
  • Product Type
  • Intrinsically Safe Barrier
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Reverse polarity and surge protection
  • Material
  • Plastic housing
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 120 g
 
 

About PEPPEL FUCHS BARRIER



Introducing the brilliant PEPPEL FUCHS BARRIER Model: KFD2-STC4-EX1now at a significant price cut! Enjoy a masterful blend of radiant performance and robust protection for hazardous area signal isolation, complete with DIN rail mounting flexibility. This device features single channel signal isolation (analog: 4-20 mA or 1-5 V DC) with intrinsic safety, galvanic isolation, and lightning-fast response (<10 ms). Benefit from IP20 degree protection, reverse polarity and surge protection, and LED status indicators. With our markdown offer, get the best price from Indias trusted supplier and trader today!

Versatile Application Across Industrial Environments

The PEPPEL FUCHS BARRIER is expertly designed for hazardous area signal isolation, making it ideal for use in chemical plants, refineries, and process industries. Its surface application suits control panels and instrumentation cabinets, while DIN-rail mounting ensures effortless installation. Whether protecting signal integrity in power plant operations or facilitating safe communications in manufacturing sites, this device delivers dependable performance in demanding conditions.


Pragmatic Export Policy and Efficient Dispatch

Our Sample Policy for the PEPPEL FUCHS BARRIER is clear and customer-orientedsamples provided upon confirmation at the list price. Delivery time is swift after packing & dispatch, typically within a few days from order confirmation. We ship to major export markets across India and beyond, with freight arrangements tailored to your requirements. Robust packing ensures that your product arrives safely and ready for installation.


FAQs of PEPPEL FUCHS BARRIER:


Q: How does the PEPPEL FUCHS BARRIER ensure safety in hazardous environments?

A: The PEPPEL FUCHS BARRIER utilizes intrinsic safety mechanisms and galvanic isolation to prevent electrical faults in hazardous areas, minimizing the risk of explosions and protecting equipment.

Q: What are the primary plant applications for this barrier device?

A: This barrier is primarily used in industrial plants such as chemical processing facilities, refineries, and power stations requiring reliable analog signal isolation and explosion protection.

Q: When can I expect the delivery of my order after placing it?

A: Once the order and packing & dispatch details are confirmed, delivery typically occurs within a few days, ensuring prompt arrival for urgent operational requirements.

Q: Where should the PEPPEL FUCHS BARRIER be installed for optimal performance?

A: Install the barrier on a DIN rail inside control panels or instrumentation cabinets, ensuring access to screw terminals and adequate ventilation for effective natural convection cooling.

Q: What benefits does the LED status indicator provide for users?

A: The LED status indicator offers quick visual feedback on device operation, helping users monitor the systems health and identify issues without complex diagnostics.

Q: How does reverse polarity and surge protection enhance device longevity?

A: Reverse polarity and surge protection safeguards the barrier from electrical mishaps, prolonging its functional life and preventing damage due to incorrect wiring or voltage spikes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Working Temperature : 20C to +60C

Operating Temperature : 20C to +60C

Storage Temperature : 25C to +85C

Product Type : Intrinsic Safety Barrier

Power Supply : 24 V DC

Features : DIN rail mount, LED indicator, galvanic isolation

PEPPERL+FUCHS Z728

PEPPERL+FUCHS Z728

Working Temperature : 20 to +60 C

Operating Temperature : 20 to +60 C

Storage Temperature : 25 to +70 C

Product Type : PEPPERL+FUCHS Z728

Power Supply : 24 V DC supply

Features : Repeater power supply with relay contact output, DIN rail mountable, LED indication

PEPPERL+FUCHS KFA6-SR2-EX2.W

PEPPERL+FUCHS KFA6-SR2-EX2.W

Working Temperature : 20C to +60C

Operating Temperature : 20C to +60C

Storage Temperature : 20C to +70C

Product Type : Intrinsic Safety Barrier

Power Supply : External DC Supply

Features : Intrinsic Safety Signal Transmission

PEPPERL + FUCHS AMPLIFIER MODULE KFD2-SR2-2.2S

PEPPERL + FUCHS AMPLIFIER MODULE KFD2-SR2-2.2S

Working Temperature : 20 C to +60 C

Operating Temperature : 20 C to +60 C

Storage Temperature : 40 C to +80 C

Product Type : Amplifier Module (KFD2SR22.2S)

Power Supply : 24 V DC

Features : Intrinsic safety, galvanic isolation, dualchannel, relay output contacts



Back to top