PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

PEPPEL FUCHS BARRIER Specification

  • Output Type
  • Signal isolation
  • Connector Type
  • Screw terminals
  • Output Current
  • Up to 100 mA (typical)
  • Phase
  • Single Phase
  • Cooling Method
  • Natural convection
  • Application
  • Hazardous area signal isolation
  • Working Temperature
  • -20C to +60C
  • Power Supply
  • 24 V DC typical
  • Features
  • DIN-rail mounting, LED status indicator, galvanic isolation
  • Rated Current
  • Max. 100 mA
  • Operating Temperature
  • -20C to +60C
  • Current Range
  • 0100 mA
  • Product Type
  • Intrinsically Safe Barrier
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Reverse polarity and surge protection
  • Material
  • Plastic housing
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 120 g
  • Safety Type
  • Intrinsic safety (explosion protection)
  • Dimensions
  • 114.5 mm x 20 mm x 124.5 mm
  • Model
  • KFD2-STC4-EX1
  • Mounting Type
  • DIN rail
  • Channel Type
  • Single channel
  • Signal Type
  • Analog (4-20 mA or 1-5 V DC)
  • Response Time
  • < 10 ms
  • Degree of protection
  • IP20
  • Isolation Voltage
  • 250 V AC (input/output/power)
 
 

About PEPPEL FUCHS BARRIER



Introducing the brilliant PEPPEL FUCHS BARRIER Model: KFD2-STC4-EX1now at a significant price cut! Enjoy a masterful blend of radiant performance and robust protection for hazardous area signal isolation, complete with DIN rail mounting flexibility. This device features single channel signal isolation (analog: 4-20 mA or 1-5 V DC) with intrinsic safety, galvanic isolation, and lightning-fast response (<10 ms). Benefit from IP20 degree protection, reverse polarity and surge protection, and LED status indicators. With our markdown offer, get the best price from Indias trusted supplier and trader today!

Versatile Application Across Industrial Environments

The PEPPEL FUCHS BARRIER is expertly designed for hazardous area signal isolation, making it ideal for use in chemical plants, refineries, and process industries. Its surface application suits control panels and instrumentation cabinets, while DIN-rail mounting ensures effortless installation. Whether protecting signal integrity in power plant operations or facilitating safe communications in manufacturing sites, this device delivers dependable performance in demanding conditions.


Pragmatic Export Policy and Efficient Dispatch

Our Sample Policy for the PEPPEL FUCHS BARRIER is clear and customer-orientedsamples provided upon confirmation at the list price. Delivery time is swift after packing & dispatch, typically within a few days from order confirmation. We ship to major export markets across India and beyond, with freight arrangements tailored to your requirements. Robust packing ensures that your product arrives safely and ready for installation.


FAQs of PEPPEL FUCHS BARRIER:


Q: How does the PEPPEL FUCHS BARRIER ensure safety in hazardous environments?

A: The PEPPEL FUCHS BARRIER utilizes intrinsic safety mechanisms and galvanic isolation to prevent electrical faults in hazardous areas, minimizing the risk of explosions and protecting equipment.

Q: What are the primary plant applications for this barrier device?

A: This barrier is primarily used in industrial plants such as chemical processing facilities, refineries, and power stations requiring reliable analog signal isolation and explosion protection.

Q: When can I expect the delivery of my order after placing it?

A: Once the order and packing & dispatch details are confirmed, delivery typically occurs within a few days, ensuring prompt arrival for urgent operational requirements.

Q: Where should the PEPPEL FUCHS BARRIER be installed for optimal performance?

A: Install the barrier on a DIN rail inside control panels or instrumentation cabinets, ensuring access to screw terminals and adequate ventilation for effective natural convection cooling.

Q: What benefits does the LED status indicator provide for users?

A: The LED status indicator offers quick visual feedback on device operation, helping users monitor the systems health and identify issues without complex diagnostics.

Q: How does reverse polarity and surge protection enhance device longevity?

A: Reverse polarity and surge protection safeguards the barrier from electrical mishaps, prolonging its functional life and preventing damage due to incorrect wiring or voltage spikes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Output Current : Limited output current (refer model for exact value)

Connector Type : Screw terminal connectors

Material : Industrial grade plastic housing

Line Regulation : Maintains reliable line regulation

Output Type : Other, Signal transmission barrier (safe/protected output)

Storage Temperature : 25C to +70C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Output Current : Up to 60 mA (per channel)

Connector Type : Screw Terminal

Material : Polycarbonate Enclosure

Line Regulation : 0.1%

Output Type : Other, Barrier analog/digital (Galvanic Isolation)

Storage Temperature : 25C to +70C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Output Current : Max. 50 mA

Connector Type : Screw terminals

Material : Plastic housing

Line Regulation : < 0.1%

Output Type : Other, Relay

Storage Temperature : 25C to +70C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Connector Type : Screw Terminal

Material : Plastic, Polycarbonate Housing

Output Type : Other, Signal Isolation/Transmission

Storage Temperature : 25C to +70C



Back to top