PEPPERL+FUCHS KFD2-ER-EX1.W.LB
PEPPERL+FUCHS KFD2-ER-EX1.W.LB

PEPPERL+FUCHS KFD2-ER-EX1.W.LB

PEPPERL+FUCHS KFD2-ER-EX1.W.LB Specification

  • Connector Type
  • Removable terminal blocks
  • Features
  • Relay output, line fault detection, hazardous area approved (ATEX), LED indication, removable terminals
  • Output Current
  • Max. 6 A at 250 V AC, Max. 6 A at 24 V DC
  • Phase
  • Single-phase signal output
  • Cooling Method
  • Natural air convection
  • Rated Current
  • Max. 6 A
  • Operating Temperature
  • -20C to +60C
  • Noise Level
  • Silent relay operation
  • Current Range
  • Control signal relay only; switching up to 6 A
  • Power Factor
  • Not applicable for signal relay modules
  • Rated Power
  • Signal-level switching (relays do not provide rated power output)
  • Power Supply
  • 24 V DC nominal
  • Working Temperature
  • -20C to +60C
  • Output Type
  • Relay contact; changeover (SPDT)
  • Application
  • Use in hazardous area signal isolation and relay switching, suitable for process automation
  • Product Type
  • 1-channel relay module with relay contact output for hazardous areas
  • Output Power
  • Standard relay switching (no power rating, signal level)
  • Output Frequency
  • DC switching relay output (not frequency based)
  • Input Voltage
  • 20 V DC to 35 V DC
  • Voltage Protection
  • Reverse polarity protection integrated
  • Efficiency
  • Industrial efficiency, optimized for control signal relay
  • Material
  • Polycarbonate enclosure
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 150 g
 
 

About PEPPERL+FUCHS KFD2-ER-EX1.W.LB



Discover a dazzling deal with the top-rated PEPPERL+FUCHS KFD2-ER-EX1.W.LB relay, designed for imposing performance in hazardous area signal isolation. Equipped with superb features like binary electronic relay switching, integrated line fault detection, and LED status indication, this relay guarantees safety and reliability. Mountable on a 35 mm DIN rail, it supports both NO/NC contacts and can handle loads up to 250 V AC/6 A. With limited stock available, it is tailored for seamless integration into DCS, PLC, and ESD systems, making it ideal for demanding industrial environments. Dont miss this exclusive product!

Exceptional Versatility Across Industrial Applications

The PEPPERL+FUCHS KFD2-ER-EX1.W.LB excels in mounting on standard DIN rails, making it suitable for diverse industrial surfaces. Its application is fundamental in environments requiring reliable signal isolation and relay switching, particularly in hazardous areas. Specifically used in process automation, it integrates effortlessly with DCS, PLC, and ESD systems, ensuring operational safety and efficiency for facilities handling electronic control signals in oil, gas, chemical, and manufacturing plants.


Reliable Certifications and Assured Market Value

Holding certifications like ATEX II (1)G and compliance with EN 60079-11/EN 60079-0 standards, the KFD2-ER-EX1.W.LB assures superb safety. Its commanding market value is bolstered by the offer of sample availability and secure shipping options across India. Backed by consistent supply ability from trusted suppliers and traders, you can confidently secure this product for your hazardous area process control requirements, guaranteeing efficiency and peace of mind in every delivery.


FAQs of PEPPERL+FUCHS KFD2-ER-EX1.W.LB:


Q: How does the PEPPERL+FUCHS KFD2-ER-EX1.W.LB provide intrinsic safety in hazardous areas?

A: The relay is ATEX II (1)G certified and compliant with EN 60079-11/EN 60079-0 standards, making it suitable for mounting in hazardous locations with high safety demands.

Q: What are the primary application areas for this relay module?

A: It is mainly used for signal isolation and relay switching in process automation, ideal for industries such as oil & gas, chemical processing, and manufacturing.

Q: Where can I mount the KFD2-ER-EX1.W.LB?

A: Installation is straightforward on a 35 mm DIN rail according to EN 60715, making it compatible with standard industrial control panels.

Q: What types of systems can this relay interface with?

A: This relay can seamlessly integrate with DCS, PLC, and ESD systems, enhancing process control and automation applications.

Q: How does the integrated line fault detection work?

A: The relay features intelligent line fault detection and rejection of false input signals, ensuring accurate and error-free control operations in critical processes.

Q: When is it beneficial to use this relay over standard models?

A: Its benefit is most pronounced in hazardous area applications requiring intrinsic safety, superior reliability, and where signal integrity is crucial.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Output Current : Max. 50 mA

Features : LED status indication, pluggable terminals, compact design

Connector Type : Screw terminals

Operating Temperature : 20C to +60C

Cooling Method : Natural convection

Storage Temperature : 25C to +70C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Output Current : Depending on model, typically 100 mA 150 mA

Features : DIN Rail mountable; LED status indication; Compact design; Maintenance free; Fuse protected

Connector Type : Screw Terminal

Operating Temperature : 20C to +60C

Cooling Method : Natural convection

Storage Temperature : 25C to +70C

PEPPERL+FUCHS  KFD2-STC4-EX1 (2)

PEPPERL+FUCHS KFD2-STC4-EX1 (2)

Output Current : Up to 20 mA

Features : Signal Transmission; Explosion Protection; Safe Area Output

Connector Type : Screw Terminal

Operating Temperature : 20C to +60C

Cooling Method : Natural Cooling

Storage Temperature : 25C to +75C

PEPPERL + FUCHS Amplifier Module KCD2-UT2-EX1

PEPPERL + FUCHS Amplifier Module KCD2-UT2-EX1

Output Current : Up to 20 mA

Features : DIN rail mount, Input and Output Isolation, LED Status Indication, 1channel

Connector Type : Removable terminal blocks

Operating Temperature : 20C to +60C

Cooling Method : Passive

Storage Temperature : 40C to +80C