PEPPERL+FUCHS KFD2-ER-EX1.W.LB
PEPPERL+FUCHS KFD2-ER-EX1.W.LB

PEPPERL+FUCHS KFD2-ER-EX1.W.LB

PEPPERL+FUCHS KFD2-ER-EX1.W.LB Specification

  • Rated Power
  • Signal-level switching (relays do not provide rated power output)
  • Operating Temperature
  • -20C to +60C
  • Cooling Method
  • Natural air convection
  • Application
  • Use in hazardous area signal isolation and relay switching, suitable for process automation
  • Noise Level
  • Silent relay operation
  • Rated Current
  • Max. 6 A
  • Power Supply
  • 24 V DC nominal
  • Working Temperature
  • -20C to +60C
  • Current Range
  • Control signal relay only; switching up to 6 A
  • Features
  • Relay output, line fault detection, hazardous area approved (ATEX), LED indication, removable terminals
  • Power Factor
  • Not applicable for signal relay modules
  • Output Current
  • Max. 6 A at 250 V AC, Max. 6 A at 24 V DC
  • Output Type
  • Relay contact; changeover (SPDT)
  • Phase
  • Single-phase signal output
  • Connector Type
  • Removable terminal blocks
  • Product Type
  • 1-channel relay module with relay contact output for hazardous areas
  • Output Power
  • Standard relay switching (no power rating, signal level)
  • Output Frequency
  • DC switching relay output (not frequency based)
  • Input Voltage
  • 20 V DC to 35 V DC
  • Voltage Protection
  • Reverse polarity protection integrated
  • Efficiency
  • Industrial efficiency, optimized for control signal relay
  • Material
  • Polycarbonate enclosure
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 150 g
  • Terminal Type
  • Screw terminals
  • Relay Contact Type
  • Changeover (SPDT); NO/NC contacts
  • System Integration
  • Can be used with DCS, PLC, and ESD systems
  • Dimensions (W x H x D)
  • 20 mm x 119 mm x 115 mm
  • Rejection of false signals
  • Integrated line fault detection and rejection of false input signals
  • Relay Life
  • Mechanical: 10 million cycles; Electrical: 100,000 cycles at full load
  • Protection Class
  • IP20
  • Intrinsic Safety
  • Suitable for mounting in hazardous area; ATEX II (1)G [Ex ia] IIC
  • LED Indication
  • Status and fault indication
  • Relay Type
  • Electromechanical
  • Mounting Type
  • DIN rail (35 mm) EN 60715
  • Safety Standard
  • EN 60079-11, EN 60079-0
  • Relay Output Load
  • 250 V AC, 6 A; 24 V DC, 6 A maximum
  • Response Time
  • Approximately 20 ms
  • Signal Type
  • Binary electronic relay switching
 
 

About PEPPERL+FUCHS KFD2-ER-EX1.W.LB



Discover a dazzling deal with the top-rated PEPPERL+FUCHS KFD2-ER-EX1.W.LB relay, designed for imposing performance in hazardous area signal isolation. Equipped with superb features like binary electronic relay switching, integrated line fault detection, and LED status indication, this relay guarantees safety and reliability. Mountable on a 35 mm DIN rail, it supports both NO/NC contacts and can handle loads up to 250 V AC/6 A. With limited stock available, it is tailored for seamless integration into DCS, PLC, and ESD systems, making it ideal for demanding industrial environments. Dont miss this exclusive product!

Exceptional Versatility Across Industrial Applications

The PEPPERL+FUCHS KFD2-ER-EX1.W.LB excels in mounting on standard DIN rails, making it suitable for diverse industrial surfaces. Its application is fundamental in environments requiring reliable signal isolation and relay switching, particularly in hazardous areas. Specifically used in process automation, it integrates effortlessly with DCS, PLC, and ESD systems, ensuring operational safety and efficiency for facilities handling electronic control signals in oil, gas, chemical, and manufacturing plants.


Reliable Certifications and Assured Market Value

Holding certifications like ATEX II (1)G and compliance with EN 60079-11/EN 60079-0 standards, the KFD2-ER-EX1.W.LB assures superb safety. Its commanding market value is bolstered by the offer of sample availability and secure shipping options across India. Backed by consistent supply ability from trusted suppliers and traders, you can confidently secure this product for your hazardous area process control requirements, guaranteeing efficiency and peace of mind in every delivery.


FAQs of PEPPERL+FUCHS KFD2-ER-EX1.W.LB:


Q: How does the PEPPERL+FUCHS KFD2-ER-EX1.W.LB provide intrinsic safety in hazardous areas?

A: The relay is ATEX II (1)G certified and compliant with EN 60079-11/EN 60079-0 standards, making it suitable for mounting in hazardous locations with high safety demands.

Q: What are the primary application areas for this relay module?

A: It is mainly used for signal isolation and relay switching in process automation, ideal for industries such as oil & gas, chemical processing, and manufacturing.

Q: Where can I mount the KFD2-ER-EX1.W.LB?

A: Installation is straightforward on a 35 mm DIN rail according to EN 60715, making it compatible with standard industrial control panels.

Q: What types of systems can this relay interface with?

A: This relay can seamlessly integrate with DCS, PLC, and ESD systems, enhancing process control and automation applications.

Q: How does the integrated line fault detection work?

A: The relay features intelligent line fault detection and rejection of false input signals, ensuring accurate and error-free control operations in critical processes.

Q: When is it beneficial to use this relay over standard models?

A: Its benefit is most pronounced in hazardous area applications requiring intrinsic safety, superior reliability, and where signal integrity is crucial.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Weight : Approx. 150 g

Cooling Method : Natural convection

Application : Hazardous area signal transmission

Input Voltage : 20 V DC to 30 V DC

Operating Temperature : 20C to +60C

Storage Temperature : 25C to +70C

PEPPERL+FUCHS KFD2-UT2-EX1(10)

PEPPERL+FUCHS KFD2-UT2-EX1(10)

Weight : Approx. 100g

Cooling Method : Natural cooling

Application : Intrinsic safety module

Input Voltage : 2030V DC

Operating Temperature : 25C to +60C

Storage Temperature : 40C to +80C

PEPPERL+FUCHS KFD2-CR-EX1.30-300

PEPPERL+FUCHS KFD2-CR-EX1.30-300

Weight : 0.2 kg

Cooling Method : Natural Convection

Application : Signal Conditioning

Input Voltage : 20 to 30 V DC

Operating Temperature : 20C to +60C

Storage Temperature : 40C to +80C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Weight : Approx. 150 g

Cooling Method : Natural Air Cooling

Application : Hazardous Area Signal Isolation

Input Voltage : 20 V to 35 V DC

Operating Temperature : 20C to +60C

Storage Temperature : 25C to +70C



Back to top