PEPPERL + FUCHS Analog Input Module KHD2-TA2/EX1 Specification

  • Operating Temperature
  • -20C to +60C
  • Current Range
  • 4-20 mA
  • Application
  • Intrinsic safety for hazardous areas, isolated analog signal transmission
  • Working Temperature
  • -20C to +60C
  • Output Current
  • 4-20 mA signal loop
  • Features
  • Intrinsic safety, galvanic isolation, 1-channel analog input
  • Power Supply
  • 24 V DC
  • Noise Level
  • Low (suitable for accurate analog measurement)
  • Connector Type
  • Screw terminals
  • Output Type
  • Analog (Current Signal)
  • Cooling Method
  • Natural convection/air cooling
  • Product Type
  • Analog Input Module
  • Output Frequency
  • N/A (Analog Signal Transfer)
  • Input Voltage
  • 24 V DC
  • Voltage Protection
  • Surge protection provided
  • Efficiency
  • High reliability designed for automation systems
  • Material
  • Industrial-grade components, plastic enclosure
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 150 g
 
 

About PEPPERL + FUCHS Analog Input Module KHD2-TA2/EX1



Explore terrific possibilities in process automation with the sizzling PEPPERL + FUCHS Analog Input Module KHD2-TA2/EX1. This first-class device is crafted for intrinsic safety in hazardous environments, making it one of the best choices for Ex areas (ATEX certified). Grab this module for seamless analog signal interfacingits galvanic isolation, 1-channel current input (4...20 mA or 0...20 mA), and robust surge protection ensure dependable and accurate data transfer. With terrific diagnostic LED indicators and a resilient, industrial-grade enclosure, its built for safety, efficiency, and reliability. Perfect for demanding process industries.

Versatile Use Across Process Automation

The PEPPERL + FUCHS KHD2-TA2/EX1 module is designed for dependable and secure analog signal transmission within process automation environments. Its intrinsic safety and galvanic isolation make it a terrific solution for hazardous areas in industrial plants, chemical facilities, and oil and gas operations. Whether you need to interface sensitive current signals or ensure top-tier safety, this module is ideal for both specialized applications and general control system use, delivering reliable performance every time.


Swift Delivery & Certified Quality Assurance

Stock ready and waiting for immediate requirements, the PEPPERL + FUCHS KHD2-TA2/EX1 can be handed over or shipped to your location across India promptly. With flexible payment terms, you can confidently secure your order. Shipped goods arrive accompanied by a suite of prestigious certifications: ATEX, IECEx, SIL, and CEvital for safety and compliance in demanding environments. Count on prompt delivery and robust international approval with every module.


FAQs of PEPPERL + FUCHS Analog Input Module KHD2-TA2/EX1:


Q: How does the PEPPERL + FUCHS KHD2-TA2/EX1 ensure safety in hazardous locations?

A: The KHD2-TA2/EX1 is ATEX and IECEx certified for explosion protection and features intrinsic safety with galvanically isolated input, output, and power supply, making it exceptionally suited for hazardous or Ex-rated process environments.

Q: What signals does the analog input module support and how many channels does it provide?

A: It supports current signals specifically 4...20 mA or 0...20 mA (as per configuration) through a single, galvanically isolated channel, perfect for accurate analog measurement.

Q: When should I use this module in my automation system?

A: You should use it when reliable and safe analog signal interfacing is needed, especially in environments requiring stringent explosion protection or high accuracy such as in chemical, petrochemical, or manufacturing process automation.

Q: Where can the KHD2-TA2/EX1 be mounted and how does it connect to the system?

A: The module is designed for DIN rail mounting, offering straightforward integration into industrial control panels with screw terminal connectors for easy, robust wiring.

Q: What are the commercial benefits of choosing this input module for my project?

A: By using the KHD2-TA2/EX1, you benefit from low noise performance, high reliability, swift diagnostics via LED indicators, and compliance with major international certifications ensuring operational efficiency and regulatory approval for your process automation.

Q: How is the ordering and delivery process managed for this product?

A: The item is stock ready, and upon order confirmation, it can be quickly handed over or shipped to your designated address, with payment terms tailored for industrial buyers.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Weight : Approx. 120 g

Cooling Method : Natural air convection

Connector Type : Pluggable screw terminals

Working Temperature : 20C to +60C

Input Voltage : 24 V DC

Voltage Protection : Surge Protected

PEPPERL+FUCHS KFD2-SL2-EX1.LK

PEPPERL+FUCHS KFD2-SL2-EX1.LK

Weight : Approx. 150 g

Cooling Method : Natural convection

Connector Type : Screw terminals

Working Temperature : 20 to +60 C operating

Input Voltage : 20~30 V DC (typical 24 V DC)

Voltage Protection : Reverse polarity, surge and transient protection

PEPPERL+FUCHS KFD2-CRG-EX1

PEPPERL+FUCHS KFD2-CRG-EX1

Weight : Approx. 150 g

Cooling Method : Selfcooled / natural convection

Connector Type : Pluggable screw terminals

Working Temperature : 20C to +60C

Input Voltage : 20 V DC to 30 V DC

Voltage Protection : Reverse polarity protection

PEPPERL+FUCHS KFD2-HMM-16

PEPPERL+FUCHS KFD2-HMM-16

Weight : 150g

Cooling Method : Natural cooling

Connector Type : Screw terminal

Working Temperature : 20C to +60C

Input Voltage : 2030V DC

Voltage Protection : Overvoltage protection



Back to top