SIEMENS 7SR4502-1JB20-1AAD/EE RELAY Specification

  • Application
  • Feeder and transformer protection in medium voltage distribution networks
  • Noise Level
  • Silent operation
  • Phase
  • Three Phase
  • Current Range
  • 1 A / 5 A (programmable via CT input)
  • Output Type
  • Relay output (Form C contacts), Ethernet/serial interface
  • Output Current
  • 8 A (maximum contact rating)
  • Cooling Method
  • Passive (natural convection)
  • Power Supply
  • Internal power supply from auxiliary input
  • Connector Type
  • Pluggable terminal blocks, communication ports (RJ45/RS485)
  • Operating Temperature
  • -25C to +60C
  • Rated Current
  • 1 A / 5 A
  • Working Temperature
  • -25C to +60C
  • Features
  • IEC 61850/ANSI/Modbus, LCD display, 4 binary inputs/outputs, configurable LEDs, event/fault recording
  • Product Type
  • Protection Relay
  • Input Voltage
  • 110-240 V AC/DC (auxiliary supply)
  • Voltage Protection
  • Yes, configurable protective functions
  • Material
  • Industry-grade flame retardant plastic and metal housing
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 2.5 kg
  • Display
  • Backlit LCD with navigation keys
  • Ingress Protection
  • IP54 front; IP20 rear
  • Model Number
  • 7SR4502-1JB20-1AAD/EE
  • Protection Functions
  • Overcurrent, earth fault, negative phase sequence, breaker fail, cold load pickup, trip circuit supervision, inrush restraint
  • Compliance
  • RoHS, REACH
  • Communication Protocols
  • IEC 61850, Modbus, DNP3, IEC 60870-5-103
  • Mounting Type
  • Flush/PANEL mounting
  • Event Recording
  • Time-tagged, non-volatile memory
 
 

About SIEMENS 7SR4502-1JB20-1AAD/EE RELAY



Experience sizzling performance with the SIEMENS 7SR4502-1JB20-1AAD/EE Relayyour gateway to top-tier protection for medium voltage networks. This gorgeous device, with its backlit LCD and intuitive navigation keys, capitalises on advanced technology like IEC 61850, Modbus, and DNP3 protocols. Featuring remarked protection functions such as overcurrent, earth fault, and breaker fail, it boasts silent operation and robust event recording. Its industry-grade, flame-retardant plastic and metal housing ensures durability, while versatile mounting options and configurable outputs suit every operation. Try Now and elevate your power distribution solutions!

Comprehensive Application for Power Distribution

The SIEMENS 7SR4502-1JB20-1AAD/EE Relay is engineered for feeder and transformer protection in medium voltage distribution networks. Suited for panel mounting on control or switchgear surfaces, it excels in managing three-phase systems. Its robust ingress protection and versatile application options make it ideal for both indoor substations and industrial power panels, ensuring reliable operation in demanding environments. Capitalise on this relays capabilities for seamless integration and remarkable operational efficiency.


Market Reach, Shipping Policy, and Certifications

Catering to the main domestic market, the SIEMENS 7SR4502-1JB20-1AAD/EE Relay is available with express shipping and convenient drop-off options. Sample units can be provided for initial valuation and testing, offering peace of mind before large-scale deployment. This product comes fully certified with RoHS and REACH compliance, validated for reliability and environmental stewardship. SIEMENS ensures that all relays meet industry-leading standards, making procurement and deployment efficient and worry-free.


FAQs of SIEMENS 7SR4502-1JB20-1AAD/EE RELAY:


Q: How does the SIEMENS 7SR4502-1JB20-1AAD/EE Relay enhance protection in power distribution networks?

A: The relay provides advanced protection with features like overcurrent, earth fault, breaker fail, and negative phase sequence detection, ensuring reliable operation for medium voltage feeders and transformers.

Q: What communication protocols are supported by this relay?

A: It supports multiple communication protocols, including IEC 61850, Modbus, DNP3, and IEC 60870-5-103, allowing seamless integration into modern SCADA and automation systems.

Q: Where can the SIEMENS 7SR4502-1JB20-1AAD/EE Relay be installed?

A: This relay is designed for flush or panel mounting, making it suitable for control rooms, switching stations, and industrial panels in medium voltage environments.

Q: What is the process for obtaining certified samples of this relay?

A: Interested parties can request sample units for valuation and evaluation before committing to larger orders, with express shipping and quick drop-off available for convenience.

Q: What are the main benefits of using this relay in medium voltage applications?

A: Key advantages include configurable protection, user-friendly LCD display, robust event recording, and compliance with RoHS and REACH, all combined in a durable, low-noise, and easy-to-install solution.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

GE DIGITAL ENERGY MULTILIN 956-0533 WESDAC D20 KHV

GE DIGITAL ENERGY MULTILIN 956-0533 WESDAC D20 KHV

Phase : Single Phase

Application : Substation Automation, Power System Control

Rated Current : Modelspecific

Operating Temperature : 10C to +60C

Product Type : Multilin 9560533 WESDAC D20 KHV

Connector Type : Screwtype terminals

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T

Phase : Three Phase

Application : Transformer differential and backup protection, substation automation

Rated Current : 1A/5A CT inputs

Operating Temperature : 10C to +60C

Product Type : Transformer Protection System

Connector Type : Screwtype terminal blocks, rear communication ports

SIEMENS 7SR1206-2JA12-1CA0/FF RELAY

SIEMENS 7SR1206-2JA12-1CA0/FF RELAY

Phase : Three Phase

Application : Protection of Power Systems (Feeder, Transformer, Generator)

Rated Current : 1A/5A CT Input

Operating Temperature : 20C to +60C

Product Type : Numerical Overcurrent & Earth Fault Relay

Connector Type : Plugin Terminals

SIEMENS 7SR1205-2HA12-1CA0/FF RELAY

SIEMENS 7SR1205-2HA12-1CA0/FF RELAY

Phase : Other, 3 Phase

Application : Feeder protection, distribution, and industrial automation systems

Rated Current : Up to 5A nominal

Operating Temperature : 25C to +70C

Product Type : Protection Relay (Numerical)

Connector Type : Screw Terminal, Plugin connectors



Back to top