GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T Specification

  • Power Supply
  • Universal AC/DC power supply
  • Noise Level
  • < 40 dB (silent electronic relay operation)
  • Cooling Method
  • Natural convection
  • Application
  • Transformer differential and backup protection, substation automation
  • Operating Temperature
  • -10C to +60C
  • Working Temperature
  • -10C to +60C
  • Output Type
  • Digital relay outputs / alarm contacts
  • Connector Type
  • Screw-type terminal blocks, rear communication ports
  • Output Current
  • Configurable outputs per control requirements
  • Phase
  • Three Phase
  • Rated Power
  • System dependent, relay power 40W typical
  • Rated Current
  • 1A/5A CT inputs
  • Features
  • Dual-slope restraining, advanced diagnostics, event recording, IEC 61850 communication
  • Current Range
  • Nominal: 1A/5A CT inputs
  • Product Type
  • Transformer Protection System
  • Output Frequency
  • 50Hz / 60Hz compatible
  • Input Voltage
  • 110-250V AC/DC
  • Voltage Protection
  • Integrated voltage, current, and frequency protection
  • Efficiency
  • High operational efficiency, typically >98%
  • Material
  • Industrial-grade enclosure; Front face metal/plastic
  • Line Regulation
  • Advanced line compensation algorithms
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 57 kg
  • Humidity Range
  • 5%95% non-condensing
  • Contact Outputs
  • Up to 16 programmable logic outputs
  • Mounting Type
  • Rack/Panel mount
  • Display Type
  • Backlit LCD graphical display
  • Firmware Upgradeability
  • Remote and local upgrade supported
  • Input Contacts
  • 12 optically isolated digital inputs
  • Model Number
  • T60T03HKHF8NH6DM8LP67U6DW6T
  • Communication Protocols
  • IEC 61850, Modbus, DNP3, RS232, Ethernet
  • Metering Accuracy
  • 0.2% typical
  • Isolation Voltage
  • 2kV between communication and power circuits
  • Event Recording
  • Oscillography and sequence of events
  • Protection Functions
  • Differential, overcurrent, ground fault, voltage, frequency
  • Service Life
  • >15 years typical
 
 

About GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T



Experience top-tier transformer protection with the GE Multilin T60 Transformer Protection System T60T03HKHF8NH6DM8LP67U6DW6T, a premier solution for advanced substation automation. This wondrous device features an immaculate backlit LCD graphical display, sizzling high operational efficiency (>98%), and comprehensive differential, overcurrent, and ground fault protection. With dual-slope restraining, robust diagnostics, and remote firmware upgradeability, your power assets gain reliable, long-term defense. Its industrial-grade enclosure, integrated voltage and frequency safeguards, and supreme communication protocols deliver unmatched monitoring and control. Advance purchase ensures your operations are always future-ready and impeccably secure.

Exceptional Features & Versatile Applications

The GE Multilin T60 boasts an arsenal of features including lightning-fast advanced diagnostics, dual-slope restraining, and oscillography event recording. With 16 programmable outputs and 12 digital inputs, it provides immaculate functional depth for transformer differential and backup protection. This top-notch system is ideal for substation automation, offering high metering accuracy, seamless communication via IEC 61850, Modbus, and RS232, and effortless integration with both rack and panel mounting options.


Certifications, Domestic Supply, and Streamlined Delivery

Handover of the GE Multilin T60 is accompanied by certified performance, stringent safety standards, and premier operational endurance. Our seamless order processing ensures rapid response to your advance purchase needs. Delivery is efficiently managed across India, the main domestic market, guaranteeing on-time arrival and comprehensive support. Supply ability is robust, matching the demands of utilities and industrial segments with reliable after-sales and technical services at every stage.


FAQs of GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T:


Q: How does the GE Multilin T60 enhance transformer protection?

A: The GE Multilin T60 offers top-tier protection functions including differential, overcurrent, voltage, ground fault, and frequency protection, all enhanced by advanced diagnostics and event recording for rapid fault analysis and system reliability.

Q: What communication protocols are supported by this system?

A: The T60 supports IEC 61850, Modbus, DNP3, RS232, and Ethernet, enabling seamless integration and flexible connectivity in modern substation and industrial environments.

Q: When can I expect delivery after placing an order for the GE Multilin T60?

A: Delivery is efficiently managed with streamlined handover and order processing, ensuring prompt dispatch and arrival across India according to your projects timeline.

Q: Where is the GE Multilin T60 most suitably used?

A: This system is designed for transformer differential and backup protection in substations, providing reliable service in utility and industrial installations requiring high operational security.

Q: What are the benefits of using the advanced firmware upgradeability feature?

A: Remote and local firmware upgrades allow you to keep your system up-to-date with the latest enhancements and features, minimizing downtime and future-proofing your protection infrastructure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

Output Type : Other, Relay Contact

Connector Type : Screw terminals

Phase : Three Phase

Features : Feeder protection, advanced metering, event recording, waveform capture, IEC 61850/MODBUS/IEC 60870 protocol support, large graphic display, flexible configuration

Storage Temperature : 40C to +85C

Current Range : 1 A / 5 A nominal (configurable inputs)

ABB REB500 RELAY

ABB REB500 RELAY

Output Type : Other, Multiple digital and analog relay outputs

Connector Type : Plugin terminal blocks (rear/front access)

Phase : Other, Three phase system compatible

Features : Distributed architecture, fast protection, modular, disturbance recorder, IEC 61850 protocol, selfsupervision, event logging, HMI

Storage Temperature : 40C to +85C

Current Range : 1 A / 5 A nominal (CT input)

SIEMENS 7SR1002-1HA10-1CA0 RELAY

SIEMENS 7SR1002-1HA10-1CA0 RELAY

Output Type : Other, Relay Contacts

Connector Type : Plugin/Terminal Block

Phase : Other, Single Phase/Three Phase

Features : Overcurrent, Earth Fault, Sensitive Earth Fault Protection, Self Monitoring, LED Status Indicator, Programmable Functionality, Event Logging

Storage Temperature : 25C to +70C

Current Range : Configurable (Protection Setpoints)

ABB REF543KM127 AAAA RELAYS (REF543)

ABB REF543KM127 AAAA RELAYS (REF543)

Output Type : Other, Relay Contacts (NO/NC)

Connector Type : Plugin Terminal Connectors

Phase : Other, Three Phase / Single Phase Compatible

Features : Feeder Protection, Multiple Communication Protocols, Programmable Functions, Disturbance Recorder

Storage Temperature : 40C to +85C

Current Range : 1/5 A (Programmable)



Back to top