PEPPERL+FUCHS KFD2-SL2-EX1.LK
PEPPERL+FUCHS KFD2-SL2-EX1.LK

PEPPERL+FUCHS KFD2-SL2-EX1.LK

PEPPERL+FUCHS KFD2-SL2-EX1.LK Specification

  • Features
  • Line fault detection, SMART transmitter compatibility
  • Phase
  • Single Phase
  • Cooling Method
  • Natural convection
  • Power Supply
  • Power Rail or direct connection
  • Operating Temperature
  • -20C to +60C
  • Output Current
  • Max. 23 mA per channel
  • Rated Power
  • 0.7 W typical
  • Noise Level
  • Low noise output
  • Rated Current
  • 23 mA
  • Application
  • Process automation, safe area signal transmission
  • Working Temperature
  • -20C to +60C
  • Output Type
  • Relay contact (SPDT)
  • Current Range
  • 4 mA to 20 mA
  • Connector Type
  • Screw terminals
  • Product Type
  • SMART Transmitter Power Supply / Isolated Barrier
  • Output Power
  • Typically 12 V
  • Output Frequency
  • DC output
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Surge and reverse polarity protection
  • Efficiency
  • High efficiency design
  • Material
  • Industrial grade plastic enclosure
  • Line Regulation
  • 0.01%
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 150 g
  • Isolation
  • 3-way isolation (input/output/power)
  • Housing Material
  • Polycarbonate
  • Response Time
  • < 10 ms
  • Mounting Type
  • DIN rail mounting
  • Dimensions
  • 40 mm x 115 mm x 115 mm (W x H x D)
  • Signal Transmission
  • HART compatible
  • Channels
  • 1 channel
  • Transmission Method
  • Intrinsic safety barrier
  • Protection Type
  • Intrinsic safety (Ex ia)
  • Input Type
  • Analog (4-20 mA)
  • Relay Output Rating
  • 250 V AC, 2 A
  • System Integration
  • Can be integrated into standard control systems
 
 

About PEPPERL+FUCHS KFD2-SL2-EX1.LK



Unlock superior reliability and performance with the exclusive PEPPERL+FUCHS KFD2-SL2-EX1.LK, engineered for premier process automation. This brilliant device features a single channel DIN rail mounting, offering best price value for critical applications. Enjoy seamless HART-compatible signal transmission, 3-way isolation, and relay output ratings up to 250 V AC, 2 A. The gorgeous industrial-grade plastic enclosure ensures durability, while surge and reverse polarity protection safeguard your investment. High efficiency, low noise, and SMART transmitter compatibility make it the ideal choice for safe area signal transmission in demanding environments.

Optimized for Safe Area Process Automation

The PEPPERL+FUCHS KFD2-SL2-EX1.LK is specifically designed for process automation, providing intrinsic safety and reliable analog (4-20 mA) signal transmission. It is widely used in industries such as chemical, pharmaceutical, and manufacturing, where precise control and safety are paramount. Engineers and automation specialists prefer this device for its effortless integration with standard control systems, making operations both streamlined and secure. Its robust polycarbonate housing and convenient DIN rail mounting suit both new installations and system upgrades.


Sample Dispatch, Secure Packaging, and Certifications

Samples of the PEPPERL+FUCHS KFD2-SL2-EX1.LK can be requested by submitting a purchase order. Units are dispatched within secure, industry-standard packaging, ensuring safe delivery. Each device comes with relevant certifications, verifying its adherence to intrinsic safety and performance standards. The overall outlay also includes detailed product documentation for smooth set-up. With our efficient supply process in India, customers experience prompt delivery, reliable support, and peace of mind when selecting this trusted automation solution.


FAQs of PEPPERL+FUCHS KFD2-SL2-EX1.LK:


Q: How does the PEPPERL+FUCHS KFD2-SL2-EX1.LK ensure safe signal transmission?

A: This device operates as an intrinsic safety barrier, offering 3-way isolation between input, output, and power, effectively protecting both equipment and personnel in process automation environments.

Q: What type of input and output does this device support?

A: It supports analog input signals (4-20 mA) and provides relay contact output (SPDT), making it suitable for a wide range of control and monitoring applications.

Q: Where can the KFD2-SL2-EX1.LK be installed?

A: The device is mounted on a DIN rail, allowing easy installation in control panels within industrial automation settings, especially in safe area signal transmission applications.

Q: When can I receive a sample of this device?

A: Samples are dispatched promptly upon receipt of a purchase order. Packaging is secure, and supporting documentation is included for a seamless evaluation process.

Q: What are the benefits of using this device in automation systems?

A: It delivers high efficiency, low noise output, advanced line fault detection, and seamless integration with standard control systems, ensuring optimal performance and reliability in demanding industrial environments.

Q: How does voltage protection work in the KFD2-SL2-EX1.LK?

A: The device includes built-in surge and reverse polarity protection, safeguarding internal components and ensuring stable, long-term operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPERL+FUCHS Z967

PEPPERL+FUCHS Z967

Power Supply : Loop powered (no external supply required)

Product Type : Zener Barrier

Material : ABS Plastic Housing

Application : Intrinsic safety; control systems; hazardous area protection

Input Voltage : 24 V DC (nominal)

Operating Temperature : 20C to +60C

PEPPERL + FUCHS Amplifier Module KFD2-SR2-EX1.W.LB

PEPPERL + FUCHS Amplifier Module KFD2-SR2-EX1.W.LB

Power Supply : Via bus or direct terminal connection

Product Type : Amplifier Module

Material : Plastic housing

Application : Intrinsic safety, signal isolation, process automation

Input Voltage : 19 V DC to 30 V DC

Operating Temperature : 20C to +60C

PEPPERL + FUCHS Amplifier Module KSD2-BO-EX

PEPPERL + FUCHS Amplifier Module KSD2-BO-EX

Power Supply : 24 V DC nominal

Product Type : Amplifier Module

Material : Plastic enclosure

Application : Intrinsic safety applications, hazardous area signal interface

Input Voltage : 19.2 V DC to 30 V DC

Operating Temperature : 20C to +60C

PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1

PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1

Power Supply : 19 V DC to 30 V DC

Product Type : Amplifier Module

Material : Plastic housing

Application : Hazardous area signal amplification, intrinsic safety barrier

Input Voltage : 19 V DC to 30 V DC

Operating Temperature : 20C to +60C



Back to top