GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T Specification

  • Application
  • Transformer Protection, Differential Protection, Control & Monitoring
  • Output Current
  • 5A max (Relay)
  • Operating Temperature
  • -10 C to +60 C
  • Connector Type
  • Pluggable terminal blocks
  • Power Factor
  • >0.98
  • Phase
  • Three Phase
  • Cooling Method
  • Natural Air Cooling
  • Rated Current
  • 5A
  • Features
  • Advanced Differential and Overcurrent Protection, Remote Communications, Modular Design, Event Recording
  • Rated Power
  • 30 W max.
  • Power Supply
  • Universal AC/DC source
  • Working Temperature
  • -10 C to +60 C
  • Noise Level
  • 55 dB
  • Current Range
  • 1/5A CT, Configurable
  • Output Type
  • Digital and Relay Outputs
  • Product Type
  • Transformer Protection System
  • Output Power
  • 10 VA
  • Output Frequency
  • 50/60 Hz
  • Input Voltage
  • 24 - 250V DC / 110 - 250V AC
  • Voltage Protection
  • User-programmable Voltage Protection
  • Efficiency
  • 98%
  • Material
  • High Impact Flame Retardant Plastic
  • Line Regulation
  • 1% typ.
  • Storage Temperature
  • -40 C to +85 C
  • Weight
  • Approx. 8.5 kg
  • Relay Outputs
  • 8 (programmable)
  • Ingress Protection
  • IP40 (front)
  • Display Type
  • LCD, 320 x 240 pixels
  • Communication Ports
  • RS232, RS485, Ethernet
  • Mounting Type
  • Panel Mount
  • Protection Functions
  • Differential, Restricted Earth Fault, Overcurrent, Thermal Overload
  • Model Number
  • T60T03HKHF8NH6DM8LP67U6DW6T
  • Firmware Upgrade
  • Via Ethernet/Serial
  • Event Recorder
  • 4096 events
  • Frequency Accuracy
  • ± 0.02 Hz
  • Time Synchronization
  • IRIG-B, SNTP/NTP
  • Disturbance Recorder
  • Expandable up to 40 seconds recording
  • Digital Inputs
  • 16 (programmable)
 
 

About GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T



Jump on the opportunity to enhance your power system reliability with the illustrious GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM (Model: T60T03HKHF8NH6DM8LP67U6DW6T). This pivotal device delivers optimum transformer protection, featuring advanced differential and overcurrent protection functionalities. Enjoy seamless control and monitoring via its clear LCD display, accessible programming, and robust remote communications. Grab yours to safeguard transformers with differential, thermal, and earth fault protection. Engineered with high-impact, flame-retardant plastic and modular design, the T60 ensures 98% efficiency and optimum performance. Access diverse featuresquick firmware upgrades, extensive event logging, and digital flexibilityall from Indias reliable supplier and trader.

Application Method, Media & Machine Features: Elevating Transformer Protection

The GE MULTILIN T60 Transformer Protection System is directly panel-mounted and built for optimum transformer monitoring and control across extensive utility and industrial grids. Application is seamlessjust integrate with digital or relay outputs and interface using its pluggable terminal blocks. With a robust suite of programmable inputs, an LCD display, and modular architecture, it excels in differential protection, event recording, and remote diagnostics. Its advanced firmware upgrade via Ethernet/Serial ensures always up-to-date pivotal protection.


Packaging Details & Purchase Process for Quick Dispatch

Supply of the GE MULTILIN T60 Transformer Protection System includes secure, industry-standard packaging for damage-free transit. Purchase orders are swiftly processed through trusted payment terms, including bank transfers and letters of credit. Our FOB port in India guarantees prompt fulfillment, ensuring quick dispatch upon order confirmation. With streamlined logistics and diligent order handling, customers can expect seamless procurement and reliable supply for all their power system protection needs.


FAQs of GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60T03HKHF8NH6DM8LP67U6DW6T:


Q: How is the GE MULTILIN T60 Transformer Protection System installed?

A: The T60 is designed for panel mounting, making installation efficient and adaptable to control room layouts. Connector types include pluggable terminal blocks for easy and secure wiring.

Q: What are the main protection features included in the GE MULTILIN T60?

A: This system covers advanced differential protection, restricted earth fault, overcurrent, and thermal overload protection, making it a comprehensive solution for transformer safeguarding.

Q: Where can the GE MULTILIN T60 be used for optimal effectiveness?

A: The T60 is ideal for utility substations, industrial facilities, and critical infrastructure requiring pivotal transformer protection, monitoring, and control.

Q: When should firmware upgrades be performed on the T60?

A: Firmware can be conveniently updated via Ethernet or Serial whenever a new version is released or critical improvements are required, ensuring the system remains at optimum performance.

Q: What benefits does the event recorder and disturbance recorder provide?

A: The built-in event recorder logs up to 4096 events, while the disturbance recorder is expandable for up to 40 seconds, offering detailed insights for diagnostics and analysis after system occurrences.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

SIEMENS 7SR1002-1LA20-2CA0/DD RELAY

SIEMENS 7SR1002-1LA20-2CA0/DD RELAY

Working Temperature : 25C to +55C

Material : Industrialgrade Plastic & Metal

Output Type : Other, Digital Relay Outputs

Current Range : Up to 5A (per contact)

Weight : Approx 2 kg

Voltage Protection : Overvoltage & Undervoltage Protection

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67U67W67

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67U67W67

Working Temperature : 20C to +60C

Material : Industrial Grade, Flame Retardant Plastic and Metal Enclosure

Output Type : Other, Protective Relay Signals, Digital/Analog Outputs

Current Range : CT: 1 A / 5 A Nominal

Weight : Approx. 6.5 kg

Voltage Protection : Over/Under Voltage, Differential Protection, Restricted Earth Fault

GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67

GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67

Working Temperature : 40C to +60C

Material : Industrial Grade, Metal Enclosure

Output Type : Other, Relay Outputs, Digital/Analog Outputs

Current Range : 1A/5A nominal (CT input)

Weight : Approx. 5 kg

Voltage Protection : Over/Under voltage, Phase loss, Unbalance

SEL 071001G1G3G72810310 MOTOR PROTECTION RELAY

SEL 071001G1G3G72810310 MOTOR PROTECTION RELAY

Working Temperature : 40C to +75C

Material : Plastic Casing

Output Type : Other, Relay Contact Output

Current Range : 1720 A (Configurable)

Weight : Approx. 1.8 kg

Voltage Protection : Overvoltage, Undervoltage, Phase Loss



Back to top