GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67
GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67

GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67

GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67 Specification

  • Connector Type
  • Screw Terminal/Pluggable terminal
  • Cooling Method
  • Natural Air Cooling
  • Noise Level
  • < 50dB
  • Power Supply
  • 88-264VAC, 110-250VDC automatic selection
  • Rated Current
  • Based on CT input, 1A/5A
  • Power Factor
  • 0.98
  • Operating Temperature
  • -40C to +60C
  • Working Temperature
  • -40C to +60C
  • Application
  • Feeder automation, substation protection, industrial electrical protection
  • Phase
  • Three Phase (supported)
  • Features
  • Advanced protection, monitoring, metering, IEC 61850 support, event recording, oscillography, security, draw-out construction
  • Current Range
  • 1A/5A nominal (CT input)
  • Output Type
  • Relay Outputs, Digital/Analog Outputs
  • Product Type
  • Feeder Protection System
  • Output Frequency
  • Not Applicable (relay device)
  • Input Voltage
  • Range: 88-264VAC / 110-250VDC
  • Voltage Protection
  • Over/Under voltage, Phase loss, Unbalance
  • Efficiency
  • Up to 99%
  • Material
  • Industrial Grade, Metal Enclosure
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 5 kg
  • Data Logging
  • Event Recorder, trending, long-term storage
  • User Interface
  • Front Panel HMI, Web Interface, SCADA connectivity
  • Model Number
  • F60K03HKHF8LH6UM8LP6UU6TW67
  • Mounting Type
  • Rack/DIN Rail Mounting, Draw-out design
  • Redundancy
  • Dual-redundant Ethernet ports supported
  • Protection Functions
  • Overcurrent, earth fault, breaker failure, current unbalance, programmable logic
  • Dimensions (HxWxD)
  • 198mm x 214mm x 203mm (approx.)
  • Firmware Upgrade
  • Field upgradable via front/remote port
  • Relay Outputs
  • Up to 32 programmable outputs
  • Communication Protocols
  • Ethernet, Modbus, IEC 61850, DNP3, serial RS232/RS485
  • Alarm Annunciation
  • Programmable LEDs, audible alarms
  • Inputs
  • Up to 24 digital inputs, 8 analog inputs
  • Time Synchronization
  • IRIG-B, SNTP, IEEE 1588
  • Event Recording
  • Comprehensive Fault/Event/Oscillography (up to 128 records)
  • Display
  • Graphic LCD with keypad
 
 

About GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67



Experience instant checkout and Grab the venerable GE Multilin F60 Feeder Protection System F60K03HKHF8LH6UM8LP6UU6TW67, a valorous defender of complex electrical networks. This virtuoso device excels in advanced feeder protection, equipped with Ethernet, Modbus, IEC 61850, and more for seamless communication. Personalise your operations with up to 32 relay outputs, intuitive front panel HMI, robust web interface, and flexible draw-out design. Engineered for reliability, its industrial-grade construction and rich diagnostics deliver unwavering performance for substation automation and feeder management.

Robust Application and Versatile Features

The GE Multilin F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67 is expertly engineered for feeder automation, substation protection, and broad industrial electrical safeguarding. It is used as a core protector in demanding environments, supporting three-phase operations. Featuring a graphic LCD with keypad, programmable LEDs, and a capacious event recorder, it provides advanced protection, sophisticated monitoring, and seamless SCADA connectivity, ensuring precise and reliable performance under all operating conditions.


Sample Policy, FOB, and Main Domestic Market

GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67 units are handed over under a transparent sample policy at the lowest price. FOB port facilities guarantee efficient drop-off options for buyers, while prompt shipping supports nationwide accessibility. The main domestic market covers all regions throughout India, making it convenient for suppliers and traders to access and deploy this advanced protection system as per project requirements.


FAQs of GE MULTILIN F60 FEEDER PROTECTION SYSTEM F60K03HKHF8LH6UM8LP6UU6TW67:


Q: How does the GE Multilin F60 enhance protection in industrial and substation environments?

A: The GE Multilin F60 provides valorous protection by offering advanced features such as overcurrent, earth fault, breaker failure, and programmable logic. Its versatile network protocols and draw-out design make it a reliable choice for demanding industrial and substation applications.

Q: What are the main communication protocols supported by this system?

A: This system excels as a virtuoso with Ethernet, Modbus, IEC 61850, DNP3, and serial RS232/RS485 protocols, ensuring seamless integration with multiple automation and SCADA environments.

Q: Where can the GE Multilin F60 be mounted for best use?

A: Thanks to its flexible rack or DIN rail mounting and rugged draw-out design, the system can be securely installed in industrial panels, substations, or switchgear rooms for optimal accessibility and safety.

Q: When is event recording or data logging particularly useful?

A: Comprehensive event recording and oscillography are especially useful after fault events or disturbances, allowing detailed analysis and troubleshooting to bolster future system reliability and protection.

Q: What is the process for firmware upgrades and operator interface access?

A: Firmware can be effortlessly upgraded via the front or remote port, while operators can personalise settings through the friendly front panel HMI, web interface, or SCADA access points for full operational control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

SIEMENS 7SJ8041-5EB20-1FC2/DD  PROTECTION RELAY

SIEMENS 7SJ8041-5EB20-1FC2/DD PROTECTION RELAY

Minimum Order Quantity : 1 Piece

Voltage Protection : Selectable voltage protection levels, Under/Over Voltage protection

Operating Temperature : 25C to +70C

Connector Type : Screw terminal

Cooling Method : Selfcooled

Application : Transformer, feeder, and generator protection

GE MULTILIN 820-0325/04 RELAY ( NEW OPAN BOX )

GE MULTILIN 820-0325/04 RELAY ( NEW OPAN BOX )

Minimum Order Quantity : 1 Piece

Voltage Protection : Surge and Over/Under Voltage Protection

Operating Temperature : 10C to +60C

Connector Type : Terminal Block

Cooling Method : Natural Air Cooling

Application : Industrial Protection and Control

SIEMENS 7SR1004-3LA20-2DA0/DD RELAY

SIEMENS 7SR1004-3LA20-2DA0/DD RELAY

Voltage Protection : Over/Under Voltage Protection

Operating Temperature : 20C to +60C

Connector Type : Screw Terminal

Cooling Method : Natural Air Cooling

Application : Feeder Protection, Industrial Automation, Electrical Distribution

SIEMENS 7SR1053-2LA21-2EA0/BB RELAY

SIEMENS 7SR1053-2LA21-2EA0/BB RELAY

Voltage Protection : Yes

Operating Temperature : 10C to +55C

Connector Type : Plugin screw terminal

Cooling Method : Natural air cooled

Application : Feeder, Transformer, Motor, and Generator protection



Back to top