SIEMENS 7SR502-1JB20-1AA0/EE REYROLLE RELAY Specification

  • Operating Voltage
  • 110/230V AC, 24-250 V DC
  • Way
  • Single/Multiple Feeder
  • Base Material
  • ABS Plastic
  • Thickness
  • Standard Panel Mounting
  • Rated Operation Voltage
  • 250V AC/DC
  • Panel Type
  • Flush Mount Panel
  • Features
  • Self-diagnostic, Event Log, Disturbance Recorder, Password Protection
  • Protection Class
  • Class I
  • Cooling System
  • Natural Air Cooling
  • Control System
  • Digital/Numerical
  • Cover Material
  • UV Resistant Polycarbonate
  • Current Rating
  • 1A or 5A Nominal CT
  • Components
  • Microcontroller, Display, Keypad, Terminals
  • Cabinet Material
  • Metallic Enclosure
  • Connectivity Type
  • RS485, Ethernet (optional)
  • Rated Insulation Voltage
  • 2 kV (1 min)
  • Protection Level
  • Overcurrent & Earth Fault
  • Rated Current
  • 1A / 5A
  • Product Type
  • Numerical Protection Relay
  • Material
  • Plastic and Metal
  • Surface Finish
  • Matte
  • Standard
  • IEC 60255
  • Surface Color
  • Grey
  • Rated Voltage
  • 100-250V AC/DC
  • Frequency (MHz)
  • 50/60 Hz
  • Maximum Output Current
  • 5A
  • Dimension (L*W*H)
  • 179 mm x 110 mm x 123 mm
  • Application
  • Feeder Protection, Distribution Automation
  • IP Rating
  • Ip54
  • Display Type
  • LCD
  • Trip Output
  • 2 NO + 2 NC
  • Testing/Commissioning Mode
  • Supported
  • Operating Temperature Range
  • -25C to +55C
  • Mounting Type
  • Panel Mounting (Flush)
  • Weight
  • Approx. 1.4 kg
  • Display Language
  • English (default)
  • Power Consumption
  • <15VA
  • Humidity Range
  • 95% RH (Non-condensing)
  • Programmable Outputs
  • 3 Digital Outputs
  • Password Security
  • Multi-level Access
  • Model Number
  • 7SR502-1JB20-1AA0/EE
  • Communication Protocols
  • MODBUS, IEC 60870-5-103
  • Storage Temperature Range
  • -40C to +85C
  • Relay Type
  • Definite Time Overcurrent & Earth Fault Relay
  • Series
  • Reyrolle 7SR502
  • Status Indication
  • LEDs for Trip, Alarm, Healthy
  • Programmable Inputs
  • 4 Digital Inputs
  • Event Storage Capacity
  • Up to 512 Events
 
 

About SIEMENS 7SR502-1JB20-1AA0/EE REYROLLE RELAY



The SIEMENS 7SR502-1JB20-1AA0/EE Reyrolle Relay is a highly recommended and praiseworthy solution for reliable feeder protection and distribution automation. This top-drawer device boasts prime features such as definite time overcurrent and earth fault protection, a sizable event log, multi-level password security, and robust programmability. It operates efficiently within a wide temperature and humidity range and meets international standards. Order now to explore this advanced, panel-mounted relay, recognized for its durable construction, comprehensive status indications, and flexible communication protocols ideal for modern control systems in demanding environments.

Prime Features and Application Highlights

SIEMENS 7SR502-1JB20-1AA0/EE Reyrolle Relay is suitable for feeder protection and distribution automation in substations and industrial environments. This machine provides overcurrent and earth fault protection on flush mount panels. Its notable features include programmable inputs/outputs, self-diagnostics, and event recording. The unit combines high protection reliability with an intuitive LCD display and easy connectivity for superior monitoring. Its robust plastic and metal build with UV resistance ensures longevity even on often-exposed application surfaces.


Order, Packaging & Delivery Information

Ordering the SIEMENS 7SR502-1JB20-1AA0/EE Relay ensures you receive secure packaging designed for safe transit. Stock is ready for immediate shipment, and careful attention is given to safeguarding each unit from environmental and transport challenges. Shipment procedures are streamlined for swift and reliable delivery. Flexible payment terms are available to meet the diverse needs of suppliers and traders in India, making the overall transaction process seamless.


FAQs of SIEMENS 7SR502-1JB20-1AA0/EE REYROLLE RELAY:


Q: How does the SIEMENS 7SR502-1JB20-1AA0/EE Relay enhance feeder protection?

A: The relay provides automatic detection and isolation of overcurrent and earth fault conditions, ensuring comprehensive protection for feeders in distribution automation and substation systems.

Q: What features contribute to its praiseworthy reliability?

A: It offers programmable digital inputs/outputs, multi-level password security, event recording, and self-diagnostics, all of which combine to deliver consistent and efficient performance in challenging applications.

Q: Where can this Reyrolle Relay be ideally installed?

A: Its designed for flush panel mounting in electrical substations, distribution panels, and industrial control panels, with an IP54 rating for dust and water resistance.

Q: What is the standard process for ordering and receiving the relay?

A: After placing your order, the relay is securely packaged and prepared for shipment. With stock ready for prompt dispatch, delivery is both efficient and reliable to your specified location.

Q: When is the ideal time to use the event log and disturbance recorder features?

A: These features are best employed during commissioning, routine maintenance, or when investigating faults, enabling precise tracking and analysis of events for optimized system performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SIEMENS REYROLLE RELAY Category

SIEMENS 7SR1053-2LA21-2EA0/BB RELAYS

SIEMENS 7SR1053-2LA21-2EA0/BB RELAYS

Minimum Order Quantity : 1 Piece

Protection Level : Other, Overcurrent, Earth Fault

Standard : IEC 6025527, IEC 602551

Rated Current : 1A / 5A

Rated Insulation Voltage : 2 kV

SIEMENS 7SR1002-1KB10-2CA0/ZDD REYROLLE RELAY

SIEMENS 7SR1002-1KB10-2CA0/ZDD REYROLLE RELAY

Protection Level : Other, IP54 (Front), IP20 (Rear)

Standard : IEC 60255, IS 3231

Rated Current : 1 A / 5 A

Rated Insulation Voltage : 2 kV (RMS), 50 Hz for 1 min

SIEMENS REYROLLE RELAY

SIEMENS REYROLLE RELAY

Protection Level : Other, IP51

Standard : IEC 60255 / IS 3231

Rated Current : 1A/5A

Rated Insulation Voltage : 2kV

SIEMENS 7SR1003-1JA20-2CA0-Z/DD REYROLLE RELAY

SIEMENS 7SR1003-1JA20-2CA0-Z/DD REYROLLE RELAY

Protection Level : Other, Microprocessor based protection

Standard : IEC 60255 / EN 60255

Rated Current : 1/5A

Rated Insulation Voltage : 250V