SIEMENS 7SR4502-2HB20-1AA0/EE RELAY
SIEMENS 7SR4502-2HB20-1AA0/EE RELAY
SIEMENS 7SR4502-2HB20-1AA0/EE RELAY
SIEMENS 7SR4502-2HB20-1AA0/EE RELAY
SIEMENS 7SR4502-2HB20-1AA0/EE RELAY
SIEMENS 7SR4502-2HB20-1AA0/EE RELAY

SIEMENS 7SR4502-2HB20-1AA0/EE RELAY

SIEMENS 7SR4502-2HB20-1AA0/EE RELAY Specification

  • Working Temperature
  • -25C to +70C
  • Noise Level
  • Low
  • Operating Temperature
  • -25C to +70C
  • Output Type
  • Relay Output
  • Power Supply
  • AC/DC Universal
  • Cooling Method
  • Natural Air Cooling
  • Features
  • Numerical relay, multiple protection functions, communication support, configurable inputs/outputs, large LCD display, event and fault records
  • Application
  • Feeder Protection, Transformer Protection, Line Protection
  • Connector Type
  • Plug-in connectors
  • Current Range
  • 1A / 5A nominal (CT inputs)
  • Phase
  • Single/Three Phase compatible
  • Product Type
  • Protection Relay
  • Input Voltage
  • 24-250 V DC / 24-230 V AC (universal)
  • Voltage Protection
  • Yes
  • Efficiency
  • High operational efficiency for protection relays
  • Material
  • Plastic and Metal Housing
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 2.5 kg
 
 

About SIEMENS 7SR4502-2HB20-1AA0/EE RELAY



Redeem cutting-edge control and cost-effective reliability with the SIEMENS 7SR4502-2HB20-1AA0/EE Relay. Decorated with an unrivaled feature setsuch as LCD display, IEC 61850 support, and 8 configurable outputsthis relay finds monumental applications in feeder, transformer, and line protection. Its robust plastic-and-metal build ensures resilience while universal voltage compatibility enhances utility. Firmware upgrades via USB/front port simplify maintenance. Comprehensive event/fault records and advanced protection functions elevate safety, making this the optimal solution for sophisticated industrial settings demanding high efficiency and robust standards conformity.

Versatile Protection and Application

The SIEMENS 7SR4502-2HB20-1AA0/EE Relay is specifically designed for use in power distribution networks, transformers, and feeders. With features like 3 phase current and voltage measuring channels, 8 programmable digital inputs, and monumental event recording capacity, this relay ensures comprehensive protection. Its unrivaled compatibility with both single and three-phase systems, combined with versatile protection such as overcurrent and earth fault, makes it ideal for diverse industrial and utility environments.


Trade Terms, Packaging, and Market Reach

This SIEMENS relay is available for the export market as well as the main domestic market. Shipped in robust packaging to preserve product integrity during transit, it meets international compliance standards. Payment terms are flexible, tailored to support seamless transactions for suppliers and traders. Each order is carefully packaged and labeled for easy identification, ensuring export-quality handling that suits both local and global distribution needs.


FAQs of SIEMENS 7SR4502-2HB20-1AA0/EE RELAY:


Q: How can the SIEMENS 7SR4502-2HB20-1AA0/EE Relay be integrated into existing protection systems?

A: The relay can be panel or flush-mounted into existing systems and supports multiple communication protocols like IEC 61850 and Modbus, allowing seamless integration with modern substation automation systems.

Q: What are the key benefits of using this relay for transformer or feeder protection?

A: The relay offers high operational efficiency, advanced protection (overcurrent, earth fault, voltage, frequency), and supports real-time event and fault recording, ensuring fast diagnostics and reliable protection.

Q: Where is the SIEMENS 7SR4502-2HB20-1AA0/EE Relay commonly used?

A: It finds application in industrial power distribution, substation automation, transformer protection, and feeder line protection, meeting both utility and industrial requirements.

Q: What is the process for upgrading the relays firmware?

A: Firmware upgrades can be performed easily using the USB or front communication port, ensuring that the relay remains up-to-date with the latest features and protective capabilities.

Q: When should the event and fault records be analyzed?

A: Event and fault records, which log up to 4096 events and 32 faults, should be analyzed after any abnormal operational occurrences to aid in rapid troubleshooting and restore normal functioning.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67U67W67

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67U67W67

Voltage Protection : Over/Under Voltage, Differential Protection, Restricted Earth Fault

Working Temperature : 20C to +60C

Operating Temperature : 20C to +60C

Output Type : Other, Protective Relay Signals, Digital/Analog Outputs

Material : Industrial Grade, Flame Retardant Plastic and Metal Enclosure

Power Supply : Universal (24250 VDC / 48240 VAC)

ABB REJ525B 415BAA RELAYS (REJ525)

ABB REJ525B 415BAA RELAYS (REJ525)

Voltage Protection : Supported (Overvoltage, Undervoltage)

Working Temperature : 25C to +55C

Operating Temperature : 25C to +55C

Output Type : Other, Relay Output (Contact Type)

Material : Industrial Grade Enclosure, Plastic/Metal Mix

Power Supply : Auxiliary supply 110250 V DC, 100240 V AC

SIEMENS 7SR1053-2LA21-2EA0/BB RELAY

SIEMENS 7SR1053-2LA21-2EA0/BB RELAY

Voltage Protection : Yes

Working Temperature : 10C to +55C

Operating Temperature : 10C to +55C

Output Type : Other, Relay Contacts

Material : ABS Plastic / Metal Housing

Power Supply : Direct or auxiliary power supply 24250 V AC/DC

ABB 1MRK004816-AB RELAYS (RET670)

ABB 1MRK004816-AB RELAYS (RET670)

Voltage Protection : Integrated voltage and frequency protection functions

Working Temperature : 10C to +55C (operation)

Operating Temperature : 10C to +55C

Output Type : Other, Digital/Relay outputs, multiple contact types

Material : Industrialgrade metal enclosure

Power Supply : Redundant, 110250 V DC or 100240 V AC