SIEMENS 7SR1003-1JA20-2CA0/DD RELAY Specification

  • Power Supply
  • 24V DC External Power Supply
  • Connector Type
  • Plug-in Terminal Block
  • Features
  • Multiple Protection Functions, LCD Display, Programmable Logic, Event Recording, Fault Reports, IEC 61850 Communication
  • Phase
  • 3 Phase
  • Cooling Method
  • Natural Cooling
  • Working Temperature
  • -20C to +70C
  • Current Range
  • 1A/5A (Configurable)
  • Application
  • Feeder Protection, Transformer Protection, General Industrial Applications
  • Noise Level
  • Low
  • Output Current
  • 5A (Relay Output)
  • Output Type
  • Relay Contact Output
  • Operating Temperature
  • -20C to +70C
  • Rated Current
  • 5A
  • Product Type
  • Numerical Protection Relay
  • Output Frequency
  • 50/60 Hz Compatible
  • Input Voltage
  • 24V DC
  • Voltage Protection
  • Overvoltage and Undervoltage Protection
  • Efficiency
  • High operational reliability
  • Material
  • Industrial Grade Components
  • Line Regulation
  • Automatic
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 1.5 kg
  • Number of Inputs
  • 4 Binary Inputs
  • Relay Type
  • Self Powered or Externally Powered
  • Protection Functions
  • Overcurrent, Earth Fault, Circuit Breaker Fail, Cold Load Pickup, Trip Circuit Supervision
  • Housing Protection
  • IP54 (Front), IP20 (Rear)
  • Number of Outputs
  • 3 Relay Outputs (Configurable)
  • Display Type
  • Backlit LCD
  • Event Log Capacity
  • Up to 100 Events
  • Type of Display
  • Alphanumeric LCD
  • Dimensions (W x H x D)
  • 106 mm x 174 mm x 102 mm
  • Mounting Type
  • Flush Panel Mounting
  • Model Number
  • 7SR1003-1JA20-2CA0/DD
  • Firmware Upgradable
  • Yes (Via USB or Communication Port)
  • Communication Protocols
  • IEC 60870-5-103, Modbus, Profibus (optional)
  • Backup Battery
  • Yes
 
 

About SIEMENS 7SR1003-1JA20-2CA0/DD RELAY



Experience the latest in protection technology with the SIEMENS 7SR1003-1JA20-2CA0/DD RELAYa best-seller known for its sensational performance and monumental reliability. Boasting meritorious protection functions, this relay supports overcurrent, earth fault, and circuit breaker fail safeguards, elevating your power systems to new heights. Get it now for seamless integration with IEC 60870-5-103, Modbus, and optional Profibus protocols. The intuitive backlit LCD, programmable logic, comprehensive event recording, and industrial-grade build make this relay a superior choice for modern industrial applications. Elevate your plant safety and efficiency today!

Versatile Applications and Plant Integration

The SIEMENS 7SR1003-1JA20-2CA0/DD RELAY is engineered for a multitude of plant environments, making it an optimal fit for feeder protection, transformer safeguarding, and general industrial protection tasks. It is eminently suitable for factories, substations, and energy-intensive installations, where it is used as a reliable, configurable defense against electrical faults. The devices robust features cater to continuous industrial operations, emphasizing operational safety and consistent performance in demanding settings.


Estimate, Delivery & Sample Logistics

Packaging for the SIEMENS 7SR1003-1JA20-2CA0/DD RELAY is carried out meticulously to ensure product safety during transit. Customers can request product samples as per the established sample policy. Estimates for order fulfillment and delivery timelines are provided during order placement. Our logistics network guarantees timely dispatch and careful handling, ensuring that you receive your relay securely and efficiently. Flexible payment terms are available, facilitating a seamless purchasing experience from inquiry to installation.


FAQs of SIEMENS 7SR1003-1JA20-2CA0/DD RELAY:


Q: How is the SIEMENS 7SR1003-1JA20-2CA0/DD RELAY typically used in industrial plants?

A: This relay is commonly used for feeder and transformer protection, as well as in general industrial settings. It helps detect overcurrents, earth faults, and circuit breaker failures, ensuring equipment safety and system reliability.

Q: What are the main benefits of the relays communication protocols?

A: With IEC 60870-5-103, Modbus, and optional Profibus compatibility, the relay allows seamless integration into existing plant automation systems, providing efficient data exchange and remote monitoring capabilities.

Q: Where can the SIEMENS 7SR1003-1JA20-2CA0/DD RELAY be installed?

A: This relay is designed for flush panel mounting and is apt for power plants, substations, factories, and facilities needing industrial-grade protection and monitoring.

Q: When is firmware upgradation possible for this relay?

A: Firmware updates can be carried out at any time via USB or the communication port, enabling users to access the latest features and security improvements without removing the unit.

Q: What is the process for obtaining a sample and receiving delivery?

A: Prospective buyers may request a sample in accordance with the suppliers sample policy. Delivery estimates and logistics details are coordinated at the time of order, ensuring secure and prompt arrival.

Q: How does the backup battery enhance reliability?

A: The inclusion of a backup battery secures stored event logs, fault records, and relay settings during power interruptions, ensuring uninterrupted critical data retention.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

ELCON 1212/CW-ROS1 CARD

ELCON 1212/CW-ROS1 CARD

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Voltage Protection : Over Voltage, Under Voltage Protection

Working Temperature : 0C to +50C

Cooling Method : Natural Air Cooling

Current Range : 01A

GE DIGITAL ENERGY MULTILIN 956-0533 WESDAC D20 KHV

GE DIGITAL ENERGY MULTILIN 956-0533 WESDAC D20 KHV

Phase : Single Phase

Voltage Protection : Overvoltage, Undervoltage (as per device specification)

Working Temperature : 10C to +60C

Cooling Method : Natural air convection

Current Range : Modelspecific

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

Phase : Three Phase

Voltage Protection : Under/Overvoltage, Phase Loss, Frequency

Working Temperature : 10C to +60C

Cooling Method : Natural air cooling

Current Range : 1 A / 5 A nominal (configurable inputs)

SIEMENS 7SR4501-1GA10-1AA0/BB RELAY

SIEMENS 7SR4501-1GA10-1AA0/BB RELAY

Phase : Three Phase

Voltage Protection : Overcurrent and earth fault protection

Working Temperature : 10C to +55C

Cooling Method : Naturally cooled

Current Range : 1A / 5A CT selectable



Back to top