SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921
SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921
SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921
SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921
SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921
SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921

SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921

SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921 Specification

  • Connector Type
  • Plug-in terminals
  • Working Temperature
  • -10C to +55C
  • Operating Temperature
  • -10C to +55C
  • Features
  • Protection, Control, Measurement, Monitoring, Communications
  • Cooling Method
  • Natural air cooling
  • Power Supply
  • Self-powered or auxiliary supply
  • Current Range
  • Configurable, depending on CT rating
  • Phase
  • Three Phase
  • Application
  • Protection and control of power feeders
  • Output Type
  • Relay Outputs (Configurable)
  • Noise Level
  • Low, designed for control room environments
  • Product Type
  • Feeder Management Relay
  • Output Frequency
  • 50/60 Hz
  • Input Voltage
  • 110-250 V DC / 100-240 V AC
  • Voltage Protection
  • Configurable Overcurrent & Earth Fault Protection
  • Efficiency
  • High operational reliability
  • Material
  • Industrial Grade Plastic & Metal
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 3.1 kg
  • Relay Outputs
  • 8 programmable outputs
  • Data Logging
  • Available with time stamp
  • Measuring Functions
  • Current, Voltage, Frequency, Power
  • Oscillography
  • 16 seconds sequence recording
  • Event Records
  • Up to 512 time-tagged records
  • Communication Ports
  • RS232, RS485, Ethernet, Modbus, IEC 61850
  • Configuration Software
  • MiCOM S1 Agile
  • Display Type
  • LCD graphical display
  • Case Size
  • 4U, standard relay case
  • Relay Model
  • P632-B4901040-308-408-621-720-463-921
  • Digital Inputs
  • 8 programmable inputs
  • Fault Records
  • Up to 40 fault records
  • Mounting Type
  • Rack/Panel Mounted
  • Firmware
  • Upgradeable via USB/Ethernet
  • Enclosure Protection
  • IP52 front panel
 
 

About SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921



Discover the SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921, the famed solution for power feeder protection and control. Featuring an incomparable LCD graphical display, unbeatable price, and flawless savings, it incorporates top digital inputs and outputs for unrivalled operational reliability. Supported by advanced communication ports like RS232, RS485, Ethernet, Modbus, and IEC 61850, this relay ensures uncompromised data logging and event recording. Its industrial grade construction, configurable voltage protection, and high efficiency make it the preferred choice for Indian suppliers and traders seeking proven excellence.

Unmatched Application Versatility and Advantages

The SCHNEIDER MICOM P632 RELAY excels in diverse mediaideal for control rooms, substations, and industrial installations. With powerful features for protection, measurement, monitoring, and communications, it delivers robust advantage in operational reliability. Its application areas include three-phase power feeders, motor protection, and voltage monitoring. This relay supports efficient fault diagnosis and ensures dependable safeguarding where accuracy and durability are paramount.


Seamless Sample Availability and Domestic Market Service

Samples of the SCHNEIDER MICOM P632 RELAY are available for quick evaluation, ensuring rapid decision-making for your projects. Payment terms are designed for convenience, including options for exchange and drop-off within main domestic markets in India. With quick dispatch and flexible delivery arrangements, customer satisfaction and ease of acquisition are prioritized, making purchase and deployment straightforward for suppliers and traders nationwide.


FAQs of SCHNEIDER MICOM P632 RELAY P632-B4901040-308-408-621-720-463-921:


Q: How can I configure the voltage protection settings on the SCHNEIDER MICOM P632 RELAY?

A: You can configure overcurrent and earth fault protection settings via the MiCOM S1 Agile software, using intuitive menus for adaptable relay programming and safety optimization.

Q: What event and fault recording capabilities does the relay offer?

A: The SCHNEIDER MICOM P632 RELAY provides up to 512 time-tagged event records and 40 fault records, ensuring thorough operational documentation and reliable post-event analysis.

Q: When should I use the relays oscillography feature in power monitoring?

A: Utilize the relays oscillography (16 seconds sequence recording) during fault analysis or performance tests to capture and review precise electrical sequences over time.

Q: Where can this relay be installed for optimal performance?

A: This relay is designed for rack or panel mounting, making it suitable for use in substations, industrial control rooms, and environments requiring high protection standards.

Q: What is the process for upgrading the firmware?

A: Firmware upgrades can be performed easily via USB or Ethernet, using SCHNEIDERs official update tools to ensure your relay remains current and fully functional.

Q: How will the relay benefit my industrial application?

A: Youll benefit from top-tier protection, flexible configuration, comprehensive measurement, and robust data communicationmaximizing reliability and operational efficiency in demanding applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCHNEIDER Used PLC HMI AC DRIVE Category

Schneider TSXDEY32D2K

Schneider TSXDEY32D2K

Working Temperature : Placeholder

Connector Type : Placeholder

Operating Temperature : Placeholder

Input Voltage : Placeholder

Noise Level : Placeholder

Output Type : Other, Placeholder

MODICON QUATUM MODULE

MODICON QUATUM MODULE

Working Temperature : 0C to 60C

Connector Type : Removable terminal block

Operating Temperature : 0C to 60C

Input Voltage : 24 VDC / 5 VDC (depending on module)

Noise Level : <50 dB (ambient)

Output Type : Other, Module dependent (Discrete/Digital/Analog I/O)

Lohiya SCHNEIDER ELECTRIC HMI

Lohiya SCHNEIDER ELECTRIC HMI

Working Temperature : 0C to +50C

Connector Type : Screw terminals, RJ45 for Ethernet

Operating Temperature : 0C to +50C

Input Voltage : 24V DC

Noise Level : <50 dB

Output Type : Other, Digital display, touch output

TSX QUANTUM  CPU   140 CPS 111 00

TSX QUANTUM CPU 140 CPS 111 00

Working Temperature : 0C to 60C

Connector Type : Standard Connector

Operating Temperature : 0C to 60C

Input Voltage : 24V DC

Noise Level : Low

Output Type : Digital Output, Other



Back to top