SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J
SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J
SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J
SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J
SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J
SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J

SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J

SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J Specification

  • Operating Temperature
  • -25C to +55C
  • Working Temperature
  • -25C to +55C
  • Power Supply
  • Auxiliary (DC/AC options)
  • Features
  • Directional, Non-Directional Overcurrent & Earth Fault, Event Recording, Fault Recording, LCD Display, Communication Ports
  • Current Range
  • 1A / 5A CT Secondary (Configurable)
  • Phase
  • Three Phase
  • Application
  • Feeder Protection, Substation Automation, Motor & Transformer Protection
  • Output Type
  • Relay Contacts (Digital Outputs)
  • Noise Level
  • Low
  • Cooling Method
  • Air-cooled (Passive)
  • Rated Current
  • 5A Nominal (CT Input)
  • Connector Type
  • Screw Terminals
  • Product Type
  • Overcurrent and Earth Fault Protection Relay
  • Output Power
  • Not Applicable (Protection Relay)
  • Output Frequency
  • Not Applicable (Relay Output Type)
  • Input Voltage
  • 24 V DC / 48-250 V DC / 110-230 V AC (Auxiliary)
  • Voltage Protection
  • Overcurrent and earth fault protection
  • Efficiency
  • High (Digital measurement accuracy)
  • Material
  • Industrial Grade Plastic & Metal
  • Storage Temperature
  • -40C to +70C
  • Weight
  • Approx. 6.5 kg
  • Conformity
  • IEC 60255, IEC 61850, EN 60255 standards
  • Inputs
  • 6 programmable inputs
  • Mounting Type
  • Panel Mount
  • Display Type
  • LCD Graphical Display
  • Protection Functions
  • 50/51 (Overcurrent), 50N/51N (Earth Fault), 46 (Negative Sequence), 49 (Thermal Overload)
  • Life Span
  • > 15 years
  • Color
  • Grey
  • Event Logging
  • Up to 512 events
  • Software Interface
  • Easergy Studio
  • Dimension
  • H 260 mm x W 177 mm x D 243 mm
  • Communication Protocols
  • RS485, IEC61850, Modbus, DNP3
  • Relay Outputs
  • 8 programmable outputs
  • Password Protection
  • Yes, configuration locking
  • Model Number
  • P143211C3M0468J
  • Disturbance Records
  • Up to 4 fault records
 
 

About SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J



Grab the acclaimed SCHNEIDER MICOM P143 Overcurrent and Earth Fault Protection Relay (P143211C3M0468J) for your substation automation and feeder protection needs. This superb relay features an LCD graphical display, advanced communication protocols (RS485, IEC61850, Modbus, DNP3), and eight programmable outputs, making it perfect for industrial applications. Benefit from phenomenal protection with overcurrent, earth fault, thermal overload, and negative sequence functions. With high digital measurement accuracy, robust event logging (512 records), and sophisticated security, this featured relay ensures flawless performance and longevity, exceeding 15 years. Industrial users across India trust its durable build, password protection, and versatile mounting options.

Application and Features Overview

The SCHNEIDER MICOM P143 relay excels in a range of protection and automation roles, such as feeder, motor, and transformer protection. Its versatile features include directional and non-directional overcurrent, earth fault protection, and eight digital outputs, making usage seamless in substations and critical power infrastructure. Ideal for panel mounting, users benefit from intuitive LCD graphical display and programmable logic. Its sophisticated thermal, disturbance, and event recording capabilities make it a perfect choice for industrial reliability.


Sample Policy, Availability, and Certifications

Regarding samples, proposals can be arranged as per formal request and proposal amount. Packing & dispatch of sample relays are handled efficiently to ensure safe shipment across India. Samples are usually available depending on stock. The SCHNEIDER MICOM P143 relay holds prestigious certifications, including conformity to IEC 60255, IEC 61850, and EN 60255 standards, providing complete assurance of quality and performance. Connect with us for detailed sample and shipment processing information.


FAQs of SCHNEIDER MICOM P143 OVERCURRENT AND EARTH FAULT PROTECTION RELAY P143211C3M0468J:


Q: How does the SCHNEIDER MICOM P143 relay enhance protection in industrial settings?

A: The SCHNEIDER MICOM P143 relay provides directional and non-directional overcurrent and earth fault protection, ensuring quick response during faults in substations, feeders, and transformers. Its advanced relay logic, programmable inputs/outputs, and high digital measurement accuracy make it highly reliable for industrial protection scenarios.

Q: What communication protocols are supported by the P143211C3M0468J relay?

A: This relay supports RS485, IEC61850, Modbus, and DNP3 communication protocols, making integration with diverse SCADA and automation systems straightforward and flexible.

Q: When is it recommended to use the MICOM P143 relay?

A: The relay is ideal for deployment in medium to high-voltage substations, motor/transformer protection, and feeder circuits where reliable overcurrent and earth fault monitoring are essential. Its robust features make it suitable for both new installations and upgrades.

Q: Where can the P143211C3M0468J relay be installed?

A: This model is designed for panel mounting, typically within switchgear panels in substations, control rooms, or other protected locations within power distribution infrastructure.

Q: What is the process for obtaining a sample of the SCHNEIDER MICOM P143 relay?

A: To obtain a sample, you can send a formal request and proposal amount to the supplier or trader. Packing and dispatch are managed to ensure safe shipment, and sample availability is subject to current stock.

Q: What are the benefits of using the SCHNEIDER MICOM P143 relay in power systems?

A: Benefits include phenomenal reliability, event and fault recording, enhanced security features like password protection, compatibility with various communication protocols, and a long operational lifespan exceeding 15 years.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCHNEIDER Used PLC HMI AC DRIVE Category

SCHNEIDER ELECTRIC PLC

SCHNEIDER ELECTRIC PLC

Application : Industrial Automation, Machine Control

Operating Temperature : 0C to 55C

Storage Temperature : 40C to +85C

Working Temperature : 0C to +55C

Features : Expandable, Integrated display, Modbus support, Compact Design

Product Type : Programmable Logic Controller (PLC)

HMI  XBTGT1100

HMI XBTGT1100

Application : Industrial automation, operator interface

Operating Temperature : 0C to 50C

Storage Temperature : 20C to +60C

Working Temperature : 0C to 50C

Features : 320 x 240 pixels QVGA color touchscreen, Ethernet/serial ports, SD card slot, programmable, compact size

Product Type : HMI (Human Machine Interface)

SCHNEIDER MODULE TSX DSY 32T2K

SCHNEIDER MODULE TSX DSY 32T2K

Application : Industrial automation, PLC systems

Operating Temperature : 0C to +60C

Storage Temperature : 25C to +70C

Working Temperature : 0C to +60C

Features : LED output status indicators, removable terminal block, protection circuits

Product Type : Digital Output Module

SCHNEIDER ELECTRIC LTMCU CONTROL OPERATOR UNIT

SCHNEIDER ELECTRIC LTMCU CONTROL OPERATOR UNIT

Application : Motor control, industrial automation

Operating Temperature : 25C to +60C

Storage Temperature : 40C to +85C

Working Temperature : 25C to +60C

Features : LED indication, pushbutton control, IP20 protection

Product Type : Control Operator Unit



Back to top