SCHNEIDER MICOM P122 OVERCURRENT RELAY P122C00F112CB1 Specification

  • Output Type
  • Relay Contacts (Trip, Alarm, etc.)
  • Working Temperature
  • -10C to +60C
  • Cooling Method
  • Natural Air Cooling
  • Power Supply
  • 24-250 V AC/DC
  • Features
  • Multi-function, event recording, disturbance recording, communication port, programmable outputs
  • Noise Level
  • Silent Operation
  • Phase
  • Three Phase
  • Rated Current
  • 1 A, 5 A
  • Application
  • Protection & control in transmission and distribution substations
  • Operating Temperature
  • -10C to +60C
  • Current Range
  • 1 A / 5 A CT nominal input
  • Connector Type
  • Screw Terminal
  • Product Type
  • Overcurrent Relay
  • Output Frequency
  • 50/60 Hz
  • Input Voltage
  • 24-250 V AC/DC
  • Voltage Protection
  • Phase overcurrent, earth fault, negative sequence
  • Material
  • High Grade Industrial Plastic/Metal Enclosure
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 2.5 kg
  • Response Time
  • < 20 ms
  • Mounting Type
  • Panel Mount
  • Insulation Resistance
  • > 100 M at 500 VDC
  • Number of Binary Inputs
  • 6
  • Frequency Range
  • 4565 Hz
  • Disturbance Recorder
  • Yes
  • Display Type
  • Backlit LCD
  • Dielectric withstand voltage
  • 2 kV RMS for 1 min between all circuits to earth
  • Control Interface
  • Front panel keypad, HMI
  • Dimensions
  • 218 x 177 x 80 mm
  • Number of Binary Outputs
  • 8
  • Event Log Capacity
  • Up to 500 events
  • Communication Protocols
  • RS232, RS485, Modbus, DNP3, IEC 60870-5-103
  • Ingress Protection
  • IP54 (front panel)
  • Relay Outputs
  • Configurable (Trip, Alarm, etc.)
  • Model
  • MiCOM P122C00F112CB1
 
 

About SCHNEIDER MICOM P122 OVERCURRENT RELAY P122C00F112CB1



Take advantage of the latest innovation with the SCHNEIDER MICOM P122 OVERCURRENT RELAY P122C00F112CB1. Engineered for flawless protection and control in transmission and distribution substations, this model features a praiseworthy event log of up to 500 events and a soaring response time of less than 20 ms. Its high-grade industrial enclosure, robust communication protocols, and multi-function outputs make it the perfect addition to any modern panel. Pick yours today to ensure reliable, efficient, and advanced substation protection.

Extra Features, Versatility and Application

Packed with programmable relay outputs, a backlit LCD display, and extensive event disturbance recording, the SCHNEIDER MICOM P122 excels in adaptability. This device is suitable for use in demanding transmission and distribution substations where consistent fault detection and reliable operation are paramount. Its multi-functionality, including alarm and trip outputs as well as advanced communication options, ensures seamless integration across various substation environments and application media.


Export Markets and Shipping Details

The SCHNEIDER MICOM P122 OVERCURRENT RELAY P122C00F112CB1 is appreciated in both domestic and global markets, particularly where reliable protection is a priority. Main export markets include industry-leading regions seeking advanced substation solutions. With express shipping and efficient freight options, delivery times are minimized, ensuring timely arrival for installation. In India, the product enjoys soaring demand in all major industrial hubs and utility sectors, supported by dedicated supplier and trader networks.


FAQs of SCHNEIDER MICOM P122 OVERCURRENT RELAY P122C00F112CB1:


Q: How does the SCHNEIDER MICOM P122 relay enhance substation protection?

A: The relay offers praiseworthy protection with configurable trip, alarm outputs, and rapid response time of less than 20 milliseconds. Its event logging and disturbance recording features ensure fault analysis and operational reliability in substations.

Q: What communication protocols are supported by the MiCOM P122C00F112CB1 model?

A: This model supports RS232, RS485, Modbus, DNP3, and IEC 60870-5-103 protocols, providing flexibility for integration into diverse substation automation systems.

Q: Where can the SCHNEIDER MICOM P122C00F112CB1 be installed?

A: Designed for panel mount installation, it is most suitable for transmission and distribution substations needing flawless overcurrent and earth fault protection in a compact form factor.

Q: What is the process for configuring programmable outputs?

A: Users can easily configure outputs using the front panel keypad and human-machine interface (HMI), tailoring trip, alarm, and other relay functions to specific application needs.

Q: What are the main benefits of the relays disturbance recording and event logging capability?

A: With storage for up to 500 events and dedicated disturbance recording, users can analyze faults, improve system reliability, and optimize maintenance processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCHNEIDER Used PLC HMI AC DRIVE Category

TSX QUANTUM MODULE 140DDI35310

TSX QUANTUM MODULE 140DDI35310

Application : Placeholder for Application

Connector Type : Placeholder for Connector Type

Cooling Method : Placeholder for Cooling Method

Power Supply : Placeholder for Power Supply

Input Voltage : Placeholder for Input Voltage

Working Temperature : Placeholder for Working Temperature

Power Supplies MODICON QUATUM MODULE

Power Supplies MODICON QUATUM MODULE

Application : PLC Power Supply for MODICON Quantum Series

Connector Type : Screw Terminal Block

Cooling Method : Natural Air Cooling

Power Supply : AC to DC

Input Voltage : 120/230 V AC

Working Temperature : 0C to +60C

TSX PREMIUM PROCESS MODULE   TSX P572634M

TSX PREMIUM PROCESS MODULE TSX P572634M

Application : Industrial Automation

Connector Type : Ethernet/Serial

Cooling Method : Natural Ventilation

Power Supply : External

Input Voltage : 24V DC

Working Temperature : 0C to 60C

SCHNEIDER MODULE TSXAEY1600

SCHNEIDER MODULE TSXAEY1600

Application : PLC Automation, Industrial Control Systems

Connector Type : Removable Terminal Block

Cooling Method : Natural Convection

Power Supply : Internal Buspowered

Input Voltage : 24 V DC (nominal)

Working Temperature : 0C to 60C



Back to top