  • Operating Temperature
  • -10C to +55C
  • Phase
  • Three Phase
  • Cooling Method
  • Natural Air Cooling
  • Features
  • Multiple protection functions, compact design, digital display
  • Current Range
  • 1A / 5A (configurable)
  • Power Supply
  • Auxiliary supply via terminals
  • Output Type
  • Relay Contact
  • Noise Level
  • Low
  • Working Temperature
  • -10C to +55C
  • Rated Current
  • 1A / 5A
  • Application
  • Protection of electrical networks (feeder, transformer, motor, capacitor bank, etc.)
  • Connector Type
  • Terminal Block
  • Product Type
  • Overcurrent Relay
  • Output Frequency
  • 50/60 Hz
  • Input Voltage
  • 110 250 V AC / 24 250 V DC
  • Voltage Protection
  • Yes
  • Efficiency
  • High
  • Material
  • Plastic and Metal
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 1.2 kg
  • Dimensions (W x H x D)
  • 106 mm x 174 mm x 108 mm
  • Mounting Type
  • Panel Mount
  • Event Recording
  • Yes, with time stamping
  • Trip Indications
  • LED
  • Display Type
  • LED Status Indicators and Digital Display
  • Relay Outputs
  • 2 Changeover Contacts
  • Setting Methods
  • Keypad/Front Interface & Remote Configuration
  • Standards Compliance
  • IEC 60255
  • Communication Ports
  • RS485 (Modbus enabled)
  • Self Diagnostics
  • Yes
  • Measuring Inputs
  • Current Transformer (CT)
  • Firmware Upgradable
  • Yes
  • IP Rating
  • IP40 (front panel)
  • Protection Functions
  • Three phase overcurrent, earth fault, sensitive earth fault, negative sequence overcurrent, cold load pickup, circuit breaker failure
  • Frequency withstand
  • 2 kHz/20kV Common Mode (Impulse)
  • Model Number
  • MICOM P121 P121A00Z112CD1
 
 

About SCHNEIDER ELECTRIC MICOM P121 OVERCURRENT RELAY P121A00Z112CD1



The SCHNEIDER ELECTRIC MICOM P121 OVERCURRENT RELAY P121A00Z112CD1 represents a rare blend of outstanding engineering and advanced protection functionality. This top-rated relay ensures reliable safeguarding of electrical networks, including feeders, transformers, and motors. With its towering array of protection functionsthree phase overcurrent, earth fault, negative sequence overcurrent, and morethis device stands out as a top-drawer solution for modern infrastructures. Its digital LED display, robust panel mount design, high IP40 front rating, and Modbus-enabled RS485 port make it a bargain for any discerning supplier or trader in India seeking efficiency and versatility.

Versatile Machine Features and Broad Application Scope

The SCHNEIDER ELECTRIC MICOM P121 is not just limited to conventional network protection; it is also highly suitable for capacitor banks, commercial electrical systems, and motor safeguard applications. Its digital display and compact design enhance usability and rapid status identification, while multiple protection features make it ideal for critical industrial, utility, and commercial installations. The relays outstanding reliability ensures continuity and minimizes downtime across diverse operational environments.


Export Market, Payment Terms, and Swift Delivery

Serving a dynamic export market, the SCHNEIDER ELECTRIC MICOM P121 OVERCURRENT RELAY P121A00Z112CD1 is available with Quick Dispatch to global clients seeking robust network protection solutions. The sale price is highly competitive, and flexible payment terms are offered for convenience. A transparent sample policy provides confidence to buyers evaluating product suitability, ensuring smooth international trade transactions and customer satisfaction.


FAQs of SCHNEIDER ELECTRIC MICOM P121 OVERCURRENT RELAY P121A00Z112CD1:


Q: How does the MICOM P121 relay improve electrical network protection?

A: The MICOM P121 relay delivers outstanding protection by monitoring several fault conditions, including three-phase overcurrent, earth fault, and circuit breaker failures, ensuring the electrical network remains safeguarded and downtime is minimized.

Q: What are the main applications of the SCHNEIDER MICOM P121?

A: This device is suitable for protecting feeders, transformers, motors, and capacitor banks in commercial, utility, and industrial electrical networks, offering versatile applications and enhanced protection capabilities.

Q: Where can users configure the relay settings?

A: The MICOM P121s settings can be conveniently configured via the front keypad interface or remotely, providing flexibility and ease of use for both on-site and remote management.

Q: What are the benefits of event recording and time stamping in this relay?

A: Event recording with time stamping allows operators to analyze and review fault histories for prompt troubleshooting, improving reliability and incident response for electrical networks.

Q: How quickly can the MICOM P121 be supplied to export markets?

A: With Quick Dispatch services, this relay is efficiently shipped to both domestic and international export markets, meeting client requirements punctually.

Q: What payment terms and sample policy does the supplier offer for this product?

A: Flexible payment terms and a transparent sample policy are in place, making it easier for clients to purchase or evaluate the relay prior to committing to larger orders.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in SCHNEIDER Used PLC HMI AC DRIVE Category

SCHNEIDER ELECTRIC ATV32HU55N4 DRIVE

SCHNEIDER ELECTRIC ATV32HU55N4 DRIVE

Power Supply : Threephase, 380500 V AC

Output Current : 12 A

Operating Temperature : 10C to +50C

Phase : Three Phase

Product Type : Variable Speed Drive (VSD) / AC Drive

Cooling Method : Forced Air Cooling

SCHNEIDER ELECTRIC CPU  TSX3721101

SCHNEIDER ELECTRIC CPU TSX3721101

Power Supply : Undefined

Output Current : Undefined

Operating Temperature : Undefined

Phase : Undefined, Other

Product Type : CPU Module

Cooling Method : Undefined

schenck  Schenck bpb v001

schenck Schenck bpb v001

Power Supply : AC

Output Current : 2.4 A

Operating Temperature : 10C to 60C

Phase : Other, 3 Phase

Product Type : Schenck BPB V001

Cooling Method : Forced Air Cooling

SCHNEIDER MODULE TSX ETY 110

SCHNEIDER MODULE TSX ETY 110

Power Supply : External

Output Current : 5A

Operating Temperature : 20C to 60C

Phase : Other, Single

Product Type : Communication Module

Cooling Method : Passive



Back to top