ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4  EMERSON  TRANSMITTER
ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4  EMERSON  TRANSMITTER
ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4  EMERSON  TRANSMITTER
ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4  EMERSON  TRANSMITTER
ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4  EMERSON  TRANSMITTER
ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4  EMERSON  TRANSMITTER

ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER

ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER Specification

  • Way
  • 2-wire loop-powered system
  • Features
  • Non-contact level measurement, high accuracy, HART communication, robust industrial design
  • Base Material
  • Aluminum
  • Protection Class
  • Class I, Div 1/Div 2, Zone 0/1, ATEX/IECEx (Explosion Proof and Intrinsically Safe options)
  • Components
  • Transmitter module, antenna, process connection, display (optional)
  • Control System
  • Compatible with HART protocol control systems
  • Rated Insulation Voltage
  • 250 V AC
  • Current Rating
  • 420 mA
  • Thickness
  • Dependent on antenna/flange selection, standard approx. 5 to 10 mm for housing
  • Cabinet Material
  • Aluminum alloy
  • Panel Type
  • Field-mount unit, not panel mounted
  • Rated Current
  • 22 mA max (output loop)
  • Cover Material
  • Aluminum with painted finish
  • Protection Level
  • IP66/IP68 (depending on configuration)
  • Rated Operation Voltage
  • 1139 VDC
  • Cooling System
  • Natural convection
  • Operating Voltage
  • 1139 VDC
  • Connectivity Type
  • 420 mA with HART communication
  • Product Type
  • Radar Level Transmitter
  • Material
  • Aluminum housing with PTFE or stainless steel flange and antenna options
  • Surface Finish
  • Epoxy-polyester powder coated
  • Standard
  • IEC/EN 61010-1, NAMUR NE 21, CE Marked
  • Surface Color
  • Blue/Gray (Emerson standard industrial finish)
  • Rated Voltage
  • 24 VDC (nominal), range 1139 VDC
  • Frequency (MHz)
  • 24 GHz (microwave, radar based)
  • Maximum Output Current
  • 22 mA (420 mA analog output, loop-powered)
  • Dimension (L*W*H)
  • Approx. 250 x 150 x 120 mm (with antenna, typical)
  • Application
  • Level measurement in liquids and solids in tanks/vessels
  • IP Rating
  • IP66/IP68
  • Display Type
  • LCD digital display (optional)
  • Accuracy
  • 3 mm or 0.03% of span (whichever is greater)
  • Weight
  • Approx. 36 kg (depending on options)
  • HART Protocol
  • Supported, version 5 or 7
  • Process Temperature Range
  • -40C to +200C (dependent on model and seal options)
  • Process Pressure Range
  • -1 to +40 bar (dependent on process connection)
  • Mounting Orientation
  • Vertical, on tank/vessel top
  • Ingress Protection
  • IP66/IP68 per IEC 60529
  • Output Signal
  • 420 mA/HART digital (2-wire loop)
  • Electronics Housing
  • Aluminum, dual compartment
  • Process Connection
  • Threaded or flanged, various sizes (DN50, DN80, etc.)
  • Ambient Temperature Range
  • -40C to +80C (storage/operation)
  • Antenna Type
  • Horn or Rod, PTFE, Stainless Steel
  • Certificates/Approvals
  • ATEX, IECEx, FM, CSA, CE marked
  • Configuration
  • Through local display or remote HART communicator
  • Measuring Range
  • Up to 20 meters (with appropriate antenna)
 
 

About ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER



Unlock commanding performance and embrace a price cut on the highly in-demand ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER. Engineered for invincible reliability, this resplendent transmitter provides non-contact level measurement across a wide measuring range (up to 20 meters), with extraordinary accuracy (3 mm or 0.03%). Its robust design endures harsh process conditions, supporting temperatures from -40C to +200C and pressures up to +40 bar. Featuring IP66/IP68 protection, HART communication, and a dual compartment aluminum housing, this transmitter delivers steadfast performance for industrial liquid and solids measurement applications. Experience superior technology and unmatched durabilitynow at a reduced price.

Special Features and Application Method

The ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER stands out with invincible non-contact radar measurement, resplendent accuracy, and robust design. Suitable for vertical mounting atop tanks and vessels, it acutely gauges levels in both liquids and solids. The transmitters flexible antenna options (horn or rod, PTFE or stainless steel), versatile measuring ranges, and seamless integration through HART protocol make it ideal for demanding industrial environments seeking reliability and precision.


Sample Policy, Export Markets & Payment Terms

Our sample policy for the ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 transmitter adheres to industry standards, typically allowing interested buyers to place a sample request before committing to volume purchase orders. We efficiently handle dispatching and secure handover of units for both domestic and main export markets, notably Asia, the Middle East, and Europe. Standard payment terms include TT, LC, and other flexible arrangements to ensure smooth transaction and prompt delivery post-purchase order approval.


FAQs of ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER:


Q: How is the ROSEMOUNT 5402AH1NA2SPBCAM1C1Q4 EMERSON TRANSMITTER configured for use in tanks or vessels?

A: The transmitter is vertically mounted on the top of tanks or vessels, using either threaded or flanged process connections, and configured via local display or a remote HART communicator for precise level measurement.

Q: What process conditions can this transmitter withstand?

A: It endures demanding environments, tolerating ambient temperatures from -40C to +80C, process temperatures up to +200C (depending on model), and pressures up to +40 bar, all while maintaining exceptional accuracy.

Q: What are the benefits of using a non-contact radar level transmitter like this model?

A: Non-contact radar level measurement ensures no direct media exposure, reducing maintenance, eliminating drift, and providing reliable results even with aggressive, hot, or pressurized materials in industrial applications.

Q: Where can this transmitter be applied effectively?

A: This versatile transmitter is ideal for use in industrial tanks and vessels containing liquids or solids, across sectors such as chemicals, oil and gas, water treatment, and food processing.

Q: How does the purchasing and dispatching process work for this product?

A: After submitting a purchase order and confirming payment terms, units are promptly dispatched and handed over per agreed logistics schedules, ensuring swift delivery to client locations both domestically and internationally.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ROSEMOUNT PRESSURE TRANSMITTER Category

ROSEMOUNT 3051CG5A02A1AM5K8T1P1S5Q4 PRESSURE TRANSMITTER

ROSEMOUNT 3051CG5A02A1AM5K8T1P1S5Q4 PRESSURE TRANSMITTER

Surface Color : Other, Blue/Silver

Rated Voltage : 24 VDC

Base Material : Stainless Steel

Dimension (L*W*H) : As per model specifications

Features : High Accuracy, Compact Design, Corrosion Resistant

Maximum Output Current : As per design

ROSEMOUNT 2051 TG3A2B2151B4 KSM5D5D404 PRESSURE TRANSMITTER

ROSEMOUNT 2051 TG3A2B2151B4 KSM5D5D404 PRESSURE TRANSMITTER

Surface Color : Other, Blue/Silver

Rated Voltage : 10.5 to 42.4 VDC

Base Material : Stainless Steel

Dimension (L*W*H) : Approx. 120 x 120 x 140 mm

Features : Compact, Reliable, High Accuracy, Easy Installation

Maximum Output Current : 20 mA

ROSEMOUNT 3051CD5A22A1AM5B4DFK5L4T1Q4 PRESSURE TRANSMITTER

ROSEMOUNT 3051CD5A22A1AM5B4DFK5L4T1Q4 PRESSURE TRANSMITTER

Surface Color : Other, Blue/Grey

Rated Voltage : 24 VDC

Base Material : Stainless Steel

Dimension (L*W*H) : 150 x 120 x 140 mm (approx.)

Features : HART Communication, High Accuracy, Compact Design, Easy Installation

Maximum Output Current : 20 mA

ROSEMOUNT 3051CG5A02A1AS5K8M5Q4T1P1 PRESSURE TRANSMITTER

ROSEMOUNT 3051CG5A02A1AS5K8M5Q4T1P1 PRESSURE TRANSMITTER

Surface Color : Other, Blue/Silver

Rated Voltage : 10.5 55 VDC

Base Material : Other, 316L Stainless Steel

Dimension (L*W*H) : Approx. 120 x 60 x 65 mm (without process connection)

Features : Compact Design, Accurate Measurement, Smart HART Output

Maximum Output Current : 21 mA



Back to top