PEPPERL+FUCHS Z787.H.F Specification

  • Cooling Method
  • Natural convection
  • Working Temperature
  • -20 C ... +60 C
  • Output Type
  • Passive (relay contact or transistor output depending on instrument loop)
  • Power Supply
  • Loop powered (no separate supply required)
  • Output Current
  • Up to 50 mA
  • Connector Type
  • Screw terminals
  • Phase
  • Single Phase
  • Application
  • Intrinsic safety applications, hazardous area instrumentation
  • Features
  • DIN rail mount, polarity reversal protection, green LED for channel status indication, Ex certification
  • Operating Temperature
  • -20 C ... +60 C
  • Current Range
  • typ. 0 to 50 mA
  • Product Type
  • Zener Barrier
  • Voltage Protection
  • Yes, with intrinsic safety (Ex ia) for hazardous areas
  • Material
  • Plastic housing
  • Storage Temperature
  • -40 C ... +70 C
  • Weight
  • approx. 150 g
  • Depth
  • 110 mm
  • Signal Direction
  • Input: hazardous area / Output: safe area
  • Number of Channels
  • 2 (dual channel)
  • Response Time
  • < 1 ms
  • Model
  • Z787.H.F
  • Isolation Voltage
  • 250 V AC
  • LED Indication
  • Status indication for each channel
  • Hazardous Area Certification
  • ATEX, IECEx
  • Height
  • 110 mm
  • Polarity Protection
  • Reverse polarity protection
  • Mounting Type
  • DIN rail mounting
  • Ingress Protection
  • IP20
  • Width
  • 17.5 mm
  • Supply Current
  • max. 73 mA
 
 

About PEPPERL+FUCHS Z787.H.F



Introducing the acclaimed PEPPERL+FUCHS Z787.H.Fan enviable and grandiose leap in safety for hazardous area instrumentation. Jump on this dual-channel interface, renowned for its soaring reliability, DIN rail mounting, and compact design (17.5 mm width). Its intrinsic safety (Ex ia), ATEX and IECEx certifications, and robust reverse polarity protection make it an ideal solution for critical plant operations. Experience ultra-fast response times (<1 ms), LED channel status, and loop-powered convenience. Get it now and empower your site with advanced, passive signal isolation in a durable plastic housing.

Extensive Plant and Industrial Application

The PEPPERL+FUCHS Z787.H.F is tailored for commercial environments demanding intrinsic safety and superior signal isolation. Utilized extensively in hazardous area instrumentation, it supports complex plant applications such as oil & gas processing, chemical production, and manufacturing automation. Its dual-channel design and robust certifications ensure a reliable safeguard for operators, while easy DIN rail mounting streamlines integration for engineers across diverse industries.


Sample Policy and Transaction Terms

Our sample policy allows you to explore the product via available samples before finalizing your order. Samples can be dispatched from our designated FOB port in India upon proposal amount acceptance and agreement on sale price. After order completion, delivery is expedited to support your project timelines. This approach is designed to facilitate smooth transitions from evaluation to deployment, ensuring both technical fit and commercial satisfaction for every client.


FAQs of PEPPERL+FUCHS Z787.H.F:


Q: How does the PEPPERL+FUCHS Z787.H.F ensure intrinsic safety in hazardous locations?

A: The Z787.H.F integrates advanced intrinsic safety (Ex ia) features, with ATEX and IECEx certifications, effectively isolating and protecting input signals from hazardous areas to the safe zone, ensuring compliance with stringent safety regulations.

Q: What key commercial applications can benefit from this dual-channel isolator?

A: This device is optimal for industrial environments like refineries, chemical plants, and process automation sites where safe, reliable signal transmission and hazardous area protection are paramount.

Q: When should this model be selected over single-channel interfaces?

A: The Z787.H.F should be chosen when your system requires two independent channels for hazardous area signal input, increasing efficiency while conserving panel space thanks to its compact, dual-channel design.

Q: Where is this module typically installed within a plant environment?

A: It is typically DIN rail mounted within control cabinets or panels, positioned at the interface between hazardous and safe areas to manage and isolate instrumentation signals.

Q: What is the process for sample ordering and what can I expect upon order completion?

A: You can request samples via our supplier network; once the proposal amount and sale price are agreed upon, samples are shipped from the designated FOB port. Upon order completion, full product delivery is arranged to meet project needs.

Q: How does the loop-powered design benefit plant operations?

A: The loop-powered capability eliminates the need for auxiliary power supplies, simplifying installation and minimizing wiring complexity, which results in lower maintenance and operational costs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Storage Temperature : 25C to +70C

Product Type : Intrinsic Safety Barrier

Features : DIN Rail Mounting, LED Status Indication, Compact Design

Weight : Approx. 150 g

Working Temperature : 20C to +60C

Material : Polycarbonate Enclosure

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Storage Temperature : 25C to +70C

Product Type : Intrinsic Safety Barrier

Features : LED status indication, pluggable terminals

Weight : Approx. 150 g

Working Temperature : 20C to +60C

Material : Plastic housing

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Storage Temperature : 25C to +70C

Product Type : Intrinsic Safety Barrier

Features : DIN Rail mountable; LED status indication; Compact design; Maintenance free; Fuse protected

Weight : Approx. 150 g

Working Temperature : 20C to +60C

Material : Metal Housing

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Storage Temperature : 25C to +70C

Product Type : Intrinsic Safety Barrier

Features : Isolated, DIN Rail Mountable, LED Status Indicator

Weight : Approx. 150 g

Working Temperature : 20C to +60C

Material : Plastic Housing with Metal Parts



Back to top