PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK
PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK
PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK
PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK

PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK

PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK Specification

  • Output Current
  • 4 mA to 20 mA
  • Power Supply
  • 24 V DC (nominal)
  • Features
  • Smart diagnostics, line fault detection, high accuracy, plug-in connection
  • Connector Type
  • Screw terminals
  • Noise Level
  • < 1 mV
  • Cooling Method
  • Natural air convection
  • Power Factor
  • Not applicable for DC device
  • Rated Current
  • 20 mA max
  • Rated Power
  • Up to 650 mW depending on load
  • Operating Temperature
  • -20C to +60C
  • Application
  • Intrinsic safety applications, process automation, analog signal transmission
  • Output Type
  • 2-wire, 4 mA ... 20 mA analog current driver
  • Phase
  • Single Phase
  • Current Range
  • 4 mA to 20 mA
  • Working Temperature
  • -20C to +60C
  • Product Type
  • Smart Current Driver
  • Output Power
  • Up to 650 mW (depending on field device load)
  • Output Frequency
  • DC, not applicable
  • Input Voltage
  • 20 V DC to 35 V DC
  • Voltage Protection
  • Reverse polarity protection and surge protection
  • Efficiency
  • Typically above 80%
  • Material
  • Polycarbonate housing
  • Line Regulation
  • < 0.01 % of output range
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 150 g
  • Channel
  • 1-channel
  • Accuracy
  • < 0.1 % of span
  • Dimensions
  • 18 mm (W) x 119 mm (H) x 118 mm (D)
  • Response Time
  • < 10 ms
  • Connection Method
  • Screw terminals
  • Mounting Type
  • DIN rail (EN 60715) mountable
  • Line Fault Detection
  • Available (lead breakage and short circuit detection)
  • Galvanic Isolation
  • Input/Output/Power supply: 375 V AC
  • Signal Type
  • Analog current signal
 
 

About PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK



The PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK is ending soon and is a scarce opportunity for those seeking a premier solution in process automation. Offering a noble design with a lavish accuracy of less than 0.1% of span, this 1-channel analog current driver delivers the lowest price for top-tier performance. It mounts easily on DIN rail (EN 60715) and is crafted from durable polycarbonate. Advanced features include smart diagnostics, line fault detection, and galvanic isolation (375 V AC) for intrinsic safety. Dont miss your chancequantities are limited!

Premier Usage for Intrinsic Safety and Automation

The PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK is designed for intrinsic safety applications, process automation, and analog signal transmission. Its compact structure and robust polycarbonate housing make it ideal for industrial sites. Key features include smart diagnostics, swift response time under 10 ms, and sophisticated line fault detection. This current driver excels in environments that demand reliable, high-accuracy performance and seamless integration with 24 V DC power supplies.


Seamless Export with Secure Packaging and Delivery

Shipped goods from our premier export market are handled with care and efficiency. The PEPPERL + FUCHS KFD2-SCD2-Ex1.LK is securely packaged to ensure safe goods transport to your location. Standard FOB ports in India are available, with packaging designed for optimal protection during transit. Expect reliable delivery times, providing confidence in your supply chain and prompt project execution for both domestic and international requirements.


FAQs of PEPPERL + FUCHS Smart Current Driver KFD2-SCD2-Ex1.LK:


Q: How does the KFD2-SCD2-Ex1.LK ensure intrinsic safety in process automation?

A: The device features galvanic isolation between input, output, and power supply, preventing unwanted current flow and ensuring intrinsic safety for hazardous environments in process automation.

Q: What are the main benefits of using the KFD2-SCD2-Ex1.LK?

A: Users benefit from high accuracy, rapid response time, advanced smart diagnostics, reliable line fault detection, and efficient analog signal transmission, all within a compact, DIN rail-mountable unit.

Q: When should I use this smart current driver in my system?

A: It is ideal for systems requiring precise analog current signal control, especially in environments demanding intrinsic safety, such as chemical plants, oil refineries, or process control rooms.

Q: Where is the PEPPERL + FUCHS KFD2-SCD2-Ex1.LK typically installed?

A: The device is typically installed in industrial automation panels or process control cabinets, securely mounted on DIN rails in both hazardous and general environments.

Q: What makes the packaging and delivery process export-friendly?

A: Goods are securely packaged for international transport, shipped via standard FOB ports in India, and backed by a reliable delivery schedule suited to global export markets.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Power Supply : External 24 V DC

Cooling Method : Natural Air Cooling

Connector Type : Screw Terminals

Features : LED Indication, DIN Rail Mountable, Compact Design

Weight : Approx. 150 g

Output Type : Other, Isolated Signal

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Power Supply : 24 V DC nominal

Cooling Method : Natural convection

Connector Type : Screw terminals

Features : LED status indication, pluggable terminals, compact design

Weight : Approx. 150 g

Output Type : Other, Relay (NAMUR and Contact Input)

PEPPERL + FUCHS Amplifier Module Z179/EX

PEPPERL + FUCHS Amplifier Module Z179/EX

Power Supply : 20 V DC to 35 V DC, via terminals

Cooling Method : Natural convection

Connector Type : Screw terminals

Features : Isolation, Intrinsically Safe, Eurocard Rail Mounting, LED Status indication

Weight : Approx. 130 g

Output Type : Other, Relay output, Transistor Output (as per version)

PEPPERL+FUCHS KFD2-CD-EX1.32

PEPPERL+FUCHS KFD2-CD-EX1.32

Power Supply : 24V DC

Cooling Method : Natural cooling

Connector Type : Screw terminals

Features : Galvanic isolation Intrinsically safe interface

Weight : Approximately 150g

Output Type : DC



Back to top