PEPPERL + FUCHS Power Module KSD2-TI-EX
PEPPERL + FUCHS Power Module KSD2-TI-EX
PEPPERL + FUCHS Power Module KSD2-TI-EX
PEPPERL + FUCHS Power Module KSD2-TI-EX

PEPPERL + FUCHS Power Module KSD2-TI-EX

PEPPERL + FUCHS Power Module KSD2-TI-EX Specification

  • Operating Temperature
  • -20C to +60C
  • Features
  • Intrinsic safety; compact DIN rail mounting; LED status indication; galvanic isolation.
  • Current Range
  • 4 mA to 20 mA (field device loop)
  • Noise Level
  • Low (meets EMC standards)
  • Power Supply
  • 24 V DC (nominal)
  • Output Type
  • Isolated analog signal (transmitter supply)
  • Rated Current
  • 100 mA
  • Working Temperature
  • -20C to +60C
  • Application
  • Signal isolation and power supply for transmitters in hazardous areas
  • Power Factor
  • N/A (DC device)
  • Rated Power
  • 2 W
  • Output Current
  • max. 100 mA
  • Phase
  • Single Phase
  • Connector Type
  • Screw terminals
  • Cooling Method
  • Natural convection
  • Product Type
  • Power Module, Isolated Barrier
  • Output Power
  • up to 2 W
  • Output Frequency
  • DC (Direct Current)
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Reverse polarity protection, Surge protection
  • Efficiency
  • 80% (typical)
  • Material
  • Industrial-grade plastic casing
  • Line Regulation
  • < 0.1%
  • Storage Temperature
  • -25C to +70C
  • Weight
  • ~ 150 g
 
 

About PEPPERL + FUCHS Power Module KSD2-TI-EX



Experience the fresh standard in industrial signal isolation with the PEPPERL + FUCHS Power Module KSD2-TI-EX. This select, latest power module boasts enviable efficiency in a compact, towering design for prime installation on 35 mm DIN rails. Designed for hazardous locations, it features Ex ia IIC T4 explosion protection, galvanic isolation (375 V AC), and robust surge/voltage protection. With rapid response under 10 ms, LED indication, and isolated analog output, it delivers secure and reliable transmitter supply. Obtain top-tier performance for your critical industrial controlsbuilt with industrial-grade plastic casing and intrinsic safety for peace of mind.

Commercial Application and Benefits

The PEPPERL + FUCHS Power Module KSD2-TI-EX excels in industrial signal isolation, making it indispensable for process automation and instrumentation in hazardous areas. Utilized by oil, gas, chemical, and pharmaceutical industries, it brings a prime advantage in ensuring intrinsic safety, reliable transmitter supply, and simplified installation. Its compact DIN rail mounting allows for enviable space-saving and high-performing control systems. Users benefit from its towering reliability, accurate signal transmission, and exemplary isolation for sensitive equipment.


Sample Policy, Certifications, and Export Market

Samples of the KSD2-TI-EX are available for commercial clients at the lowest price, with swift order processing and timely shipment. Certified under stringent standards including ATEX, IECEx, FM, and CE, this module offers prime assurance for hazardous location use. Shipped to prime clients in main export markets such as India, Middle East, and Southeast Asia, buyers enjoy reliable, certified products backed by enviable safety records and technical support.


FAQs of PEPPERL + FUCHS Power Module KSD2-TI-EX:


Q: How do I install the KSD2-TI-EX power module on a DIN rail?

A: Installation is straightforwardsimply attach the module to a standard 35 mm DIN rail using its secure mounting design, then connect your wiring via screw terminals as per the instructions.

Q: What certifications does the KSD2-TI-EX module hold for hazardous areas?

A: The module is certified with ATEX, IECEx, FM, and CE, making it fully approved for use in various hazardous and explosive environments in compliance with international safety standards.

Q: Where is the KSD2-TI-EX power module commonly used?

A: It is widely employed in industries such as oil and gas, chemical processing, and pharmaceuticals for transmitter supply and signal isolation in hazardous environments.

Q: What is the sample order process for this power module?

A: Clients can request samples at the lowest price; upon order confirmation, the product is swiftly processed and shipped with comprehensive documentation and certification details.

Q: What benefit does galvanic isolation provide in the KSD2-TI-EX?

A: Galvanic isolation ensures that the signal channel and power supply are electrically separated, preventing interference and safeguarding connected devices from voltage surges or faults.

Q: How does the module indicate operational status?

A: A green LED status indicator located on the front panel provides quick visual confirmation of normal module operation, facilitating efficient monitoring and troubleshooting.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Input Voltage : 20 V DC to 30 V DC

Material : Plastic/Metal Housing

Operating Temperature : 20C to +60C

Features : LED status indication, Fault monitoring, Compact design

Voltage Protection : Reverse polarity protection integrated

Weight : Approx. 120 g

PEPPERL+FUCHS Z954

PEPPERL+FUCHS Z954

Input Voltage : 85253 V AC / 90300 V DC

Material : Highgrade Industrial Plastic

Operating Temperature : 20C to +60C

Features : DIN Rail Mounting, Compact Design, LED status indication

Voltage Protection : Overvoltage and shortcircuit protection

Weight : Approx. 150 g

PEPPERL+FUCHS Z779

PEPPERL+FUCHS Z779

Input Voltage : 250 V AC/DC max

Material : Polycarbonate housing

Operating Temperature : 20C to +60C

Features : Isolated ground, reversible polarity, DINrail mountable

Voltage Protection : Output voltage limitation via builtin Zener diodes

Weight : approx. 100 g

PEPPERL+FUCHS KFD2-STC3-EX1

PEPPERL+FUCHS KFD2-STC3-EX1

Input Voltage : 2030VDC

Material : Plastic (body)

Operating Temperature : 20C to +60C

Features : Universal usage; galvanic isolation; 1channel isolated barrier

Voltage Protection : Builtin voltage limitations

Weight : Approx. 150g



Back to top