PEPPERL FUCHS KFD2-STC4-EX1.20 SWITCH AMPLIFIER Specification

  • Output
  • Relay (2 NO contacts, 1 NO per channel)
  • Installation Type
  • DIN rail mounting
  • Features
  • 4-channel; Intrinsically safe; Input/output/power supply isolation; LED channel status; Suitable for NAMUR sensors
  • Protection Level
  • Galvanic isolation between input/output/power supply
  • Mounting Type
  • DIN rail mountable
  • Display
  • LED indication (per channel)
  • Current
  • Max. 50 mA per channel (output)
  • IP Rating
  • IP20
  • Frequency
  • 2 kHz (input signal from sensor)
  • Usage & Applications
  • Signal isolation and switching in hazardous (Ex) areas
  • Switch Type
  • Electronic Switch Amplifier
  • Connectivity Type
  • Screw terminals
  • Sensor Type
  • Namur proximity sensor or mechanical contact switches
  • Product Type
  • Switch Amplifier
  • Operating Temperature
  • -20C to +60C
  • Working Temperature
  • -20C to +60C
  • Input
  • Namur sensor or mechanical contact
  • Application
  • Intrinsically safe isolation of signals for hazardous areas
  • Supply Voltage
  • 20...35 V DC
  • Accuracy
  • High switching accuracy for sensor interface signals
  • Dimension (L*W*H)
  • 18 mm x 110 mm x 115 mm (approx.)
  • Weight
  • Approx. 120 g
  • Model Number
  • KFD2-STC4-EX1.20
  • Test/Function
  • Test button for manual function test
  • Hazardous Area Approval
  • ATEX, IECEx, FM, CSA
  • Electromagnetic Compatibility
  • EN 61326, IEC 61000
  • Connection Type
  • Removable terminal blocks
  • Power Consumption
  • Typically <1.6 W (per channel)
  • Ambient Storage Temperature
  • -40C to +80C
  • Channel Type
  • 2-channel (independent signal processing)
  • Housing Material
  • Polycarbonate (PC)
  • Relative Humidity
  • < 95% non-condensing
  • Signal Transmission
  • Electromechanical relay or transistor output
  • Status Indication
  • LED for each channel, green (power), yellow (switching status)
  • Response Time
  • 10 ms
 
 

About PEPPERL FUCHS KFD2-STC4-EX1.20 SWITCH AMPLIFIER



Experience instant savings on the masterful PEPPERL FUCHS KFD2-STC4-EX1.20 Switch Amplifier, with offers ending soon. Designed as a pivotal solution for hazardous areas, this praiseworthy 2-channel amplifier ensures fresh, highly accurate, intrinsically safe signal isolation and switching for your crucial operations. Its DIN-rail mountable, robust polycarbonate housing, equipped with intuitive LED indication and removable terminal blocks, ensures both safety and efficiency. Approved by ATEX, IECEx, FM, and CSA, its perfect for demanding industrial environments. Act quicklyenhance system reliability with this advanced switch amplifier today.

Distinctive Applications & Competitive Edge

The PEPPERL FUCHS KFD2-STC4-EX1.20 Switch Amplifier demonstrates outstanding capability in hazardous zone signal isolation and switching, making it ideal for plant automation and process industries. Its application surface accommodates both NAMUR sensors and mechanical contacts, ensuring flexibility across sectors like petrochemical, pharmaceutical, and energy. Stand out with competitive advantages such as galvanic isolation, rapid response time, and multi-standard hazardous area approval, giving your operation both safety and technological superiority.


FOB Port, Sample, and Payment Guidelines

Orders for the PEPPERL FUCHS KFD2-STC4-EX1.20 Switch Amplifier are accepted via official Purchase Order. Products are dispatched from prominent Indian FOB ports, allowing for efficient shipping logistics and reliable freight arrangements. Samples may be made available for evaluation, subject to supplier terms. Secure payment terms including bank transfer or other agreed methods ensure seamless transactions, making your procurement process as smooth as possible.


FAQs of PEPPERL FUCHS KFD2-STC4-EX1.20 SWITCH AMPLIFIER:


Q: How is the PEPPERL FUCHS KFD2-STC4-EX1.20 Switch Amplifier installed?

A: This amplifier is designed for easy DIN rail mounting, featuring removable terminal blocks for quick, secure connections.

Q: What hazardous area certifications does the switch amplifier hold?

A: It holds ATEX, IECEx, FM, and CSA approvals, making it suitable for use in a wide range of hazardous (Ex) zone applications.

Q: When should I use this switch amplifier in my plant?

A: Deploy this amplifier when you need intrinsically safe, isolated processing of input signals from NAMUR proximity sensors or mechanical contacts in challenging or hazardous environments.

Q: Where can the amplifiers status be checked?

A: Status can be monitored via individual channel LEDs on the unit, indicating both power and switching status.

Q: What benefits does the KFD2-STC4-EX1.20 provide over conventional amplifiers?

A: It delivers pivotal advantages including high switching accuracy, rapid response time, galvanic isolation, and comprehensive hazardous location approvals, enhancing both safety and reliability in industrial control systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL+FUCHS POWER SUPPLY Category

PEPPERL  FUCHS KFD2-EB.R4A.B SWITCH AMPLIFIER

PEPPERL FUCHS KFD2-EB.R4A.B SWITCH AMPLIFIER

Usage & Applications : Industrial automation, process control, signal transfer

Features : Explosion protection, galvanic isolation, LED indication, compact design

Supply Voltage : 2030 V DC

Operating Temperature : 20C to +60C

Connectivity Type : Screw terminals

Input : Digital input, Namur sensor or contact

PEPPERL  FUCHS KFD2-CD-EX1.32 SWITCH AMPLIFIER

PEPPERL FUCHS KFD2-CD-EX1.32 SWITCH AMPLIFIER

Usage & Applications : Safety isolation for field signals in hazardous areas

Features : Configurable, galvanic isolation, LED indicators, compact design

Supply Voltage : 20 V DC~35 V DC

Operating Temperature : 20C to +60C

Connectivity Type : Screw terminals

Input : 1channel; Namur/Input for dry contact

PEPPERL  FUCHS KFD2-UT2-EX1 SWITCH AMPLIFIER

PEPPERL FUCHS KFD2-UT2-EX1 SWITCH AMPLIFIER

Usage & Applications : Signal isolation, industrial automation, hazardous area protection

Features : Intrinsic safety, galvanic isolation, compact design, LED status indicators

Supply Voltage : 20 V DC to 30 V DC

Operating Temperature : 20C to +60C

Connectivity Type : Screw terminals

Input : Digital input (NAMUR and contact) 1channel

PEPPERL+FUCHS POWER SUPPLY KFD2-STC4-120

PEPPERL+FUCHS POWER SUPPLY KFD2-STC4-120

Usage & Applications : Signal isolation, reliable transmission for hazardous area instrumentation

Features : Intrinsic safety, signal isolation, multichannel, compact design

Supply Voltage : 20 to 35 V DC

Operating Temperature : 20C to +60C

Connectivity Type : Screw terminal connections

Input : 4channel, 2wire transmitters/sensors, 4 to 20 mA input



Back to top