PEPPERL+FUCHS KFD2-STC3-EX1 Specification

  • Rated Current
  • Up to 20 mA
  • Working Temperature
  • -20C to +60C
  • Application
  • Intrinsic safety applications
  • Output Type
  • Analog/digital signal barrier
  • Operating Temperature
  • -20C to +60C
  • Current Range
  • 420 mA (Input/Output current)
  • Cooling Method
  • Passive cooling
  • Features
  • Universal usage; galvanic isolation; 1-channel isolated barrier
  • Connector Type
  • Screw terminals
  • Power Supply
  • External power supply required
  • Output Current
  • 420 mA or equivalent output
  • Noise Level
  • Low noise
  • Phase
  • Single-phase
  • Product Type
  • Isolated Signal Barrier
  • Output Power
  • Signal modulation power
  • Input Voltage
  • 2030VDC
  • Voltage Protection
  • Built-in voltage limitations
  • Efficiency
  • High precision signal transfer
  • Material
  • Plastic (body)
  • Line Regulation
  • 0.1%
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 150g
 
 

About PEPPERL+FUCHS KFD2-STC3-EX1



Step into the Elite order of safety and performance with the PEPPERL+FUCHS KFD2-STC3-EX1Indias premier choice for intrinsic safety applications. Designed for phenomenal efficiency, its high-precision signal transfer and matchless galvanic isolation ensure steadfast protection in demanding environments. Featuring low noise, passive cooling, and universal usability, this 1-channel isolated barrier supports analog/digital outputs through reliable screw terminal connectors. Pick yours today to experience advanced voltage protection, seamless modulation power, and robust plastic construction. Trust the proven standard in signal barrier technology for superior results.

Commercial Deployment and Directions for Elite Usability

The PEPPERL+FUCHS KFD2-STC3-EX1 is a preferred selection for commercial environments demanding reliable intrinsic safety. Ideal across process industries, it adapts seamlessly to hazardous zones and control panels, ensuring uninterrupted signal integrity. Simple screw terminal connections allow quick installation on standard surfaces, while its compact body fits well in tight spaces. To achieve matchless barrier protection, follow provided wiring diagrams closely and connect to the recommended 2030VDC external power supply for optimal operation.


Certifications, Proposals, and Packaging: Comprehensive Details

With every KFD2-STC3-EX1 proposal amount, you are assured of certified quality and precise compliance with industrial safety standards. Sample units are available upon request for evaluation prior to bulk handover. Transportation is handled carefully, with each piece safely packed to prevent transit damage and preserve calibration. Expect detailed documentation and secure packaging with every delivery, supporting smooth installation and dependable performance from the outset.


FAQs of PEPPERL+FUCHS KFD2-STC3-EX1:


Q: How does the KFD2-STC3-EX1 contribute to intrinsic safety applications?

A: The device provides galvanic isolation and built-in voltage limitations, ensuring matchless protection against hazardous voltage spikes in critical installations.

Q: What is the recommended process for installing the KFD2-STC3-EX1?

A: To install, securely connect input and output wiring to the screw terminals, follow the wiring diagram, and ensure an external 2030VDC power supply is available for stable operation.

Q: When should I choose the KFD2-STC3-EX1 for my industrial project?

A: Select this barrier when high-precision, low-noise analog/digital signal transfer is crucial in hazardous zones, and when you require robust, universal protection in your control system.

Q: Where can the KFD2-STC3-EX1 be used for optimal performance?

A: Its compact design makes it ideal for use in confined control panels, hazardous area interfaces, and diverse surfaces throughout industrial and commercial environments.

Q: What benefits does the high efficiency and line regulation provide?

A: With 0.1% line regulation and efficient signal transmission, users benefit from increased reliability, reduced maintenance, and consistent output free from noise and interference.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Product Type : Intrinsic Safety Barrier

Material : Plastic housing (Polycarbonate/ABS)

Input Voltage : 20 V DC to 30 V DC

Operating Temperature : 20C to +60C

Working Temperature : 20C to +60C

Application : Explosion protection in hazardous area instrumentation

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Product Type : Intrinsic Safety Barrier

Material : Plastic housing

Input Voltage : 24 V DC

Operating Temperature : 20C to +60C

Working Temperature : 20C to +60C

Application : Hazardous area signal isolation

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Product Type : Intrinsically Safe Barrier

Material : Polycarbonate Housing

Input Voltage : 20 V to 35 V DC

Operating Temperature : 20C to +60C

Working Temperature : 20C to +60C

Application : Hazardous Area Signal Isolation

PEPPERL+FUCHS KFD2-SL2-EX1.LK

PEPPERL+FUCHS KFD2-SL2-EX1.LK

Product Type : Signal Conditioner Interface Module

Material : Plastic Housing

Input Voltage : 19 V DC to 30 V DC

Operating Temperature : 20C to +60C

Working Temperature : 20C to +60C

Application : Intrinsic Safety Isolation for Hazardous Areas (Ex ia) Signal Transmission



Back to top