PEPPERL+FUCHS KFD2-CRG-EX1D Specification

  • Output Type
  • Analog/digital signal output
  • Output Current
  • 12 mA
  • Connector Type
  • Terminal block
  • Cooling Method
  • Natural cooling
  • Rated Current
  • 12 mA
  • Noise Level
  • Low noise
  • Phase
  • Single-phase
  • Application
  • Intrinsic safety barrier for hazardous areas
  • Features
  • Signal isolation safety protection
  • Operating Temperature
  • -20C to +60C
  • Working Temperature
  • -20C to +60C
  • Power Supply
  • 24 V DC
  • Current Range
  • 12 mA
  • Product Type
  • KFD2-CRG-EX1D
  • Input Voltage
  • 24 V DC
  • Voltage Protection
  • Intrinsic safety protection
  • Efficiency
  • High efficiency
  • Material
  • High-quality plastic enclosure
  • Line Regulation
  • Stable voltage conversion
  • Storage Temperature
  • -25C to +75C
  • Weight
  • Approximately 150g
 
 

About PEPPERL+FUCHS KFD2-CRG-EX1D



Explore the impeccable engineering of the PEPPERL+FUCHS KFD2-CRG-EX1D, designed for resplendent signal isolation and intrinsic safety in hazardous environments. With top-notch efficiency, stable voltage conversion, and low noise operation, this safety barrier supports single-phase applications with a steady output current of 12 mA and versatile analog/digital signal outputs. Constructed from high-quality plastic for durability and lightweight handling, this device operates efficiently between -20C to +60C. Take advantage of substantial savings this exclusive offer is ending soon. Secure intrinsic safety with reliability you can trust!

Advantage & Usage of PEPPERL+FUCHS KFD2-CRG-EX1D

The PEPPERL+FUCHS KFD2-CRG-EX1D offers remarkable benefits with its intrinsic safety design and reliable signal isolation. Ideal for hazardous areas, it ensures resplendent performance in industrial automation, chemical processing, and manufacturing plants. This module is suitable for use in sectors requiring uncompromised safety, such as oil and gas, pharmaceuticals, and mining, supporting both analog and digital signals with natural cooling.


Certifications, Samples & Export Markets

Built for top-notch market value, the PEPPERL+FUCHS KFD2-CRG-EX1D comes with certified intrinsic safety assurance. Samples can be arranged upon request, bolstering buyer confidence. Exported largely to markets across India and abroad, packaging and goods transport are handled meticulously, ensuring the product arrives securely and in pristine condition. Respected among suppliers and traders, it embodies reliability and efficiency.


FAQs of PEPPERL+FUCHS KFD2-CRG-EX1D:


Q: How does the PEPPERL+FUCHS KFD2-CRG-EX1D ensure intrinsic safety?

A: The device uses advanced intrinsic safety protection to prevent electrical sparks or faults in hazardous areas, ensuring safe operation in explosive environments.

Q: What types of output signals can the KFD2-CRG-EX1D handle?

A: This safety barrier supports both analog and digital signal outputs, making it adaptable for a variety of industrial applications.

Q: Where can the KFD2-CRG-EX1D be typically used?

A: It is commonly used in hazardous industry zones such as oil and gas, chemical processing, pharmaceuticals, and mining, where reliable signal isolation is crucial.

Q: When is it necessary to install an intrinsic safety barrier?

A: Intrinsic safety barriers like the KFD2-CRG-EX1D should be installed whenever control signals need to pass between safe and hazardous zones, minimizing risk in potentially explosive atmospheres.

Q: What benefits does the natural cooling feature offer?

A: Natural cooling ensures the device operates quietly with low noise and without the need for additional fans, enhancing both reliability and energy efficiency in industrial settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPERL+FUCHS KFD2-UT2-EX1(10)

PEPPERL+FUCHS KFD2-UT2-EX1(10)

Features : Safety barrier signal conditioning

Product Type : Intrinsic Safety Barrier

Application : Intrinsic safety module

Material : Plastic housing

Connector Type : Screw terminals

Storage Temperature : 40C to +80C

PEPPERL+FUCHS KFD2-SCD-EX1.LK

PEPPERL+FUCHS KFD2-SCD-EX1.LK

Features : Explosion protection galvanic isolation signal multiplication

Product Type : Signal Conditioner

Application : Signal conditioner for hazardous areas

Material : Durable plastic housing

Connector Type : Screw terminal

Storage Temperature : 25C to +75C

PEPPERL+FUCHS Z731

PEPPERL+FUCHS Z731

Features : Galvanic isolation High reliability

Product Type : Safety barrier

Application : Intrinsic safety barrier

Material : Plastic housing

Connector Type : Screw terminals

Storage Temperature : 25C to +70C

AMPHENOL P28810

AMPHENOL P28810

Features : High reliability

Product Type : Connector

Application : Automation

Material : Metal and Plastic

Connector Type : AMPHENOL P28810

Storage Temperature : 40C to +85C



Back to top