PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W
PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W
PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W
PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W

PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W

PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W Specification

  • Rated Current
  • 2 A max
  • Features
  • 1-channel, relay output, safe signal transfer, DIN rail mount
  • Cooling Method
  • Natural convection
  • Operating Temperature
  • -20C to +60C
  • Connector Type
  • Screw terminals
  • Application
  • Intrinsic safety, signal isolation, hazardous area automation
  • Output Current
  • Max. 2 A
  • Power Supply
  • Powered from supply voltage (loop powered)
  • Working Temperature
  • -20C to +60C
  • Output Type
  • Relay (1-channel)
  • Product Type
  • Analog Output Module
  • Input Voltage
  • 20 V DC to 35 V DC
  • Voltage Protection
  • Surge protection, reverse polarity protection
  • Material
  • Plastic housing
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 150 g
 
 

About PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W



Experience the majestic reliability of the PEPPERL+FUCHS Analog Output Module KFD2-SR2-EX1.Wa crowning achievement in hazardous area automation. This stellar, in-demand module is engineered for effortless DIN rail mounting and is fully customizable for various industrial applications. Boasting swift response times under 10 ms and designed to operate in Zones 2/22, this reserve-grade device champions intrinsic safety and robust signal isolation. Enhanced with surge and reverse polarity protection, the module offers seamless integration, setting a new standard in safe, efficient signal transfer in hazardous locations.

Expansive Application Areas and Versatile Usage

The PEPPERL+FUCHS Analog Output Module KFD2-SR2-EX1.W is ideal for use in hazardous zones 2/22, ensuring both safety and reliable signal transfer. Its versatile design supports intrinsic safety and signal isolation, engineered for a range of industrial control sectors such as automation lines, petrochemical plants, and process industries. Other applications include remote relay control, monitoring, and secure data transmission in challenging environments requiring advanced protection.


Availability, Express Shipping & Transportation Details

Sample units of the PEPPERL+FUCHS Analog Output Module KFD2-SR2-EX1.W are accessible, letting you assess suitability before a full outlay. With stellar supply ability, customers in India and abroad can benefit from express shipping and reliable transportation networks. FOB Port services are available, ensuring your products are dispatched safely and promptly to your location with efficient logistics support.


FAQs of PEPPERL + FUCHS ANALOG OUTPUT MODULE KFD2-SR2-EX1.W:


Q: How can the PEPPERL+FUCHS Analog Output Module KFD2-SR2-EX1.W be installed?

A: The module is optimized for DIN rail mounting, utilizing screw terminals for simple and secure installation in electrical control cabinets.

Q: What areas is the KFD2-SR2-EX1.W best suited for?

A: It is specifically designed for use in hazardous areas classified as Zones 2 and 22, providing safe and reliable signal isolation in challenging environments.

Q: When should this output module be considered for use?

A: Deploy this module when you require intrinsic safety, rapid signal response (under 10 ms), and robust relay output for critical automation and control applications in hazardous zones.

Q: Where can I obtain sample units for testing before full deployment?

A: Sample units are available from authorized suppliers and traders in India, allowing customers to evaluate device performance prior to committing to larger orders.

Q: What benefits does surge and reverse polarity protection provide?

A: These features safeguard the module from electrical faults, maintaining operational integrity and extending the modules service life in harsh conditions.

Q: What is the supply process and shipping method for this module?

A: After placing your order, modules can be shipped from the designated FOB port, with options for express shipping and comprehensive transportation support to ensure swift delivery.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL add FUCHS BARRIER

PEPPEL add FUCHS BARRIER

Power Supply : 24 V DC external supply

Application : Hazardous area signal transfer, process automation

Voltage Protection : Reverse polarity and surge protection included

Output Type : Other, Passive and active versions available

Material : Polycarbonate housing, flame retardant

Weight : Approx. 150 g

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Power Supply : 24V DC External Supply

Application : Intrinsic Safety, Hazardous areas, Process Automation

Voltage Protection : Integrated overvoltage and shortcircuit protection

Output Type : Other, Analog/Digital signal barrier

Material : Plastic Housing

Weight : Approximately 150g

PEPPERL + FUCHS Redundant Power Feed Module KFD2-EB2.R4A.B

PEPPERL + FUCHS Redundant Power Feed Module KFD2-EB2.R4A.B

Power Supply : Redundant DC supply module

Application : Power supply redundancy for Ksystem interface devices

Voltage Protection : Overvoltage protection, reverse polarity protection

Output Type : Other, Redundant, dualchannel

Material : Polycarbonate housing

Weight : Approx. 180 g

PEPPERL+FUCHS KFD0-SD2-EX1.1045

PEPPERL+FUCHS KFD0-SD2-EX1.1045

Power Supply : 24 V DC nominal

Application : Intrinsically safe interface for NAMUR sensors and switches in hazardous areas

Voltage Protection : Reverse polarity protection, surge protection

Output Type : Other, Transistor (open collector)

Material : Polycarbonate housing

Weight : Approx. 100 g



Back to top