PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R
PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R
PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R
PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R

PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R

PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R Specification

  • Features
  • Highly reliable, intrinsically safe, suitable for hazardous areas, relay output, easy DIN rail mounting
  • Operating Temperature
  • -20C to +60C
  • Phase
  • Not Applicable (DC Powered)
  • Application
  • Signal isolation and amplification in hazardous areas (Ex applications)
  • Output Type
  • Relay contact (single pole, single throw, normally open)
  • Power Supply
  • 20 V DC to 30 V DC
  • Working Temperature
  • -20C to +60C
  • Cooling Method
  • Natural convection
  • Output Current
  • Max. 2 A
  • Rated Current
  • Max. 2 A at 40C
  • Connector Type
  • Screw terminal connections
  • Current Range
  • Max. 2 A at output contacts
  • Product Type
  • Amplifier Module
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Internal surge protection
  • Material
  • Plastic enclosure
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 150 g
  • Enclosure Rating
  • IP20
  • Isolation Voltage
  • 375 V AC (input/output/supply to each other)
  • Mounting Type
  • DIN rail mountable
  • Protection Type
  • Intrinsically safe Ex ia
  • Maximum Switching Power
  • 500 VA / 60 W
  • Model Number
  • KFD2-VR-EX1.50M.R
  • Dimensions
  • Approx. 20 mm x 119 mm x 115 mm
  • LED Indicators
  • Green LED for power and relay status
  • Maximum Switching Voltage
  • 253 V AC/125 V DC
  • Response Time
  • 10 ms
 
 

About PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R



The PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R is a special, DIN rail mountable solution pivotal for signal isolation and amplification in hazardous areas. Its intrinsically safe Ex ia rating ensures maximum protection, while the green LED indicators provide instant power and relay status updates. Decorated with an IP20 enclosure and built with a dominant 375 V AC isolation voltage, savings are guaranteed through durability and reliability. Order today to experience seamless installation, surge protection, and relay output benefits in Ex applications across India.

Strategic Application for Safe Industrial Usage

The PEPPERL + FUCHS KFD2-VR-EX1.50M.R amplifier module is expertly designed for signal isolation and amplification in hazardous (Ex) environments. Its dominant usage is found in industrial sites requiring intrinsically safe circuitry. This DIN rail mountable module offers reliable relay contact output, making it an excellent choice for critical process applications. Use type includes hazardous area installations, ensuring equipment protection and operational efficiency at chemical, oil & gas, or process automation sites.


Efficient Packaging, Payment, and Export Logistics

Each PEPPERL + FUCHS KFD2-VR-EX1.50M.R is securely packaged to prevent damage during freight. With quick dispatch available upon order confirmation, customers can expect expedited shipments at competitive freight charges. Flexible payment terms accommodate diverse client needs. Primary export markets include India and many international destinations, ensuring global reach and professional logistical support for timely product delivery. Trust in hassle-free packaging and swift transport for seamless procurement.


FAQs of PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.50M.R:


Q: How does the PEPPERL + FUCHS KFD2-VR-EX1.50M.R module ensure safety in hazardous areas?

A: The KFD2-VR-EX1.50M.R amplifier module features intrinsically safe Ex ia protection, effectively isolating and amplifying signals while minimizing the risk of sparks or electrical faults in potentially explosive environments.

Q: What are the main application sites for this amplifier module?

A: This module is predominantly used in hazardous (Ex) environments such as chemical plants, oil & gas facilities, and process automation setups requiring reliable signal isolation and amplification.

Q: When is it recommended to use this amplifier module in a project?

A: It is recommended to use this module during installations where intrinsically safe operation and high isolation voltage are crucial, especially during initial equipment setup or system upgrades in hazardous areas.

Q: Where can the module be mounted within an industrial setup?

A: The KFD2-VR-EX1.50M.R is DIN rail mountable, making it easy to install within control panels or industrial racks commonly found in process automation sites.

Q: What is the process of receiving the module after order placement?

A: Once you place your order, the product undergoes secure packaging for safe freight, with quick dispatch and competitive freight charges ensuring prompt delivery to your specified location.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Output Type : Other, Relay Output / Type N/O relay contact (varies by model)

Operating Temperature : 20C to +60C

Features : DIN Rail Mountable, LED Indicator, Removable Terminals

Weight : Approx. 150g

Product Type : Intrinsic Safety Barrier

Application : Hazardous Area, Intrinsically Safe Barriers, Signal Isolation

PEPPERL + FUCHS Amplifier Module KFD2-CD-EX1.32

PEPPERL + FUCHS Amplifier Module KFD2-CD-EX1.32

Output Type : Other, Relay contact, 1 changeover, bistable

Operating Temperature : 20C to +60C

Features : Onechannel isolated barrier, input for Namur sensor or contact, relay contact output, SIL2 rated, Power Rail support

Weight : Approx. 150 g

Product Type : Amplifier Module

Application : Signal transmission from hazardous area sensors (NAMUR) to control systems in safe area

PEPPERL + FUCHS Power Module KFDO-SD2-EX1.1045

PEPPERL + FUCHS Power Module KFDO-SD2-EX1.1045

Output Type : Other, Isolated, Ex ia output

Operating Temperature : 20C ... +60C

Features : Active current limitation, galvanic isolation, diagnostic indication

Weight : approx. 150 g

Product Type : Power Module for Intrinsically Safe Applications

Application : For supplying measuring transmitters and field devices in hazardous areas

PEPPERL+FUCHS KFD2-RR-EX1

PEPPERL+FUCHS KFD2-RR-EX1

Output Type : Other, Relay Output

Operating Temperature : 20C to +60C

Features : Intrinsically Safe Designed for Hazardous Areas

Weight : 200 g

Product Type : Signal Conditioner

Application : Signal Conditioning