PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1
PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1
PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1
PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1

PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1

PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1 Specification

  • Output Type
  • Relay contact (2 changeover relays)
  • Working Temperature
  • -20 C to +60 C
  • Output Current
  • 250 mA (per channel)
  • Application
  • Hazardous area signal amplification, intrinsic safety barrier
  • Features
  • Intrinsic safety, HART transparency, removable terminals, relay output, compact design
  • Connector Type
  • Removable terminal blocks
  • Operating Temperature
  • -20C to +60C
  • Power Supply
  • 19 V DC to 30 V DC
  • Cooling Method
  • Natural convection
  • Product Type
  • Amplifier Module
  • Input Voltage
  • 19 V DC to 30 V DC
  • Voltage Protection
  • Polarity reversal and surge protection
  • Material
  • Plastic housing
  • Storage Temperature
  • -25 C to +85 C
  • Weight
  • Approx. 150 g
  • Relay Output
  • 2 NO/NC contacts, max. 250 V AC / 2 A
  • Galvanic Isolation
  • Channel to channel and input to output and supply
  • Dimensions (W x H x D)
  • 40 mm x 115 mm x 110 mm
  • Mounting Type
  • DIN rail (35 mm) mountable
  • Ambient Humidity
  • 10% to 90% (non-condensing)
  • Approvals/Certificates
  • ATEX, IECEx, UL, CSA, FM, SIL
  • Field Device Connection
  • Suitable for NAMUR and mechanical contacts
  • Response Time
  • <10 ms
  • Degree of Protection
  • IP20
  • Channels
  • 4-channel signal amplifier
 
 

About PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1



The PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1 stands at the top of signal amplification technology, perfect for hazardous area applications. Order today to experience a glorious blend of intrinsic safety, compact design, and relay versatility. This crackerjack module boasts 4-channel capability, swift response times (<10 ms), and robust galvanic isolation. Equipped with paragon-grade approvals like ATEX, IECEx, UL, and more, it ensures ultimate reliability. The removable terminal blocks, plastic housing, and HART transparency make installation and usage seamlessOrder now from Indias leading supplier and elevate your signal management.

Exceptional Application Suitability and Method

The KFD2-STV4-EX1.20-1 amplifier module is a paragon of versatility, tailored for hazardous area signal amplification where intrinsic safety is paramount. Designed for DIN rail installation, it seamlessly integrates as an intrinsic safety barrier in industrial automation systems. Suitable for usage with both NAMUR and mechanical contacts, its compact size and removable terminals simplify both field device connections and ongoing maintenance, making it the superior choice for demanding environments requiring continuous signal integrity.


Certified Quality, Efficient Delivery & Sample Valuation

This amplifier module arrives with top certificationsATEX, IECEx, UL, CSA, FM, and SILdemonstrating its glorious international compliance. Drop-off estimates for FOB port deliveries are tailored to your location, ensuring prompt arrivals across India. Product samples are available for detailed valuation and pre-purchase assessment, helping you make a confident decision. Trust our crackerjack logistics team for swift sample provision and assured quality checks, cementing our supplier reputation for reliability and precision.


FAQs of PEPPERL + FUCHS Amplifier Module KFD2-STV4-EX1.20-1:


Q: How is the KFD2-STV4-EX1.20-1 amplifier module typically used in industrial settings?

A: It is most commonly used as a signal amplifier and intrinsic safety barrier for hazardous areas, supporting both NAMUR and mechanical contact field devices to ensure signal integrity and operational safety.

Q: What are the main benefits of ordering the PEPPERL + FUCHS KFD2-STV4-EX1.20-1?

A: Key benefits include top-tier safety certifications, fast response time, reliable galvanic isolation, and seamless installation with removable terminal blocks, all housed in a compact and robust enclosure.

Q: Where can I install this amplifier module for optimal performance?

A: The module is designed for DIN rail (35 mm) mounting, making it ideal for control panels in hazardous or industrial areas with demanding safety and integration requirements.

Q: What process is involved in connecting field devices to this amplifier module?

A: Field devicessuch as those with NAMUR or mechanical contactscan be safely and efficiently connected using the modules removable terminal blocks, ensuring easy, secure, and swift installation or maintenance.

Q: When is it recommended to request a product sample?

A: Requesting a product sample is recommended during the project planning or system upgrade phases, allowing for a thorough valuation and hands-on assessment before placing a larger order.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Operating Temperature : 20C to +60C

Material : Plastic Enclosure

Storage Temperature : 25C to +70C

Weight : Approx. 150 g

Connector Type : Screw Terminals

Working Temperature : 20C to +60C

ABB CPU

ABB CPU

Operating Temperature : 0C to +60C

Material : PCB with electronic components

Storage Temperature : 40C to +85C

Weight : 150 g

Connector Type : Screw terminal

Working Temperature : 0C to +60C

PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.18

PEPPERL + FUCHS AMPLIFIER MODULE KFD2-VR-EX1.18

Operating Temperature : 20 to +60C

Material : Plastic, Electronic Components

Storage Temperature : 40 to +80C

Weight : Approx. 120 g

Connector Type : Plugin terminals

Working Temperature : 20 to +60C

PEPPERL+FUCHS KFD2-SR2-EX2W

PEPPERL+FUCHS KFD2-SR2-EX2W

Operating Temperature : 20C to 60C

Material : Plastic housing

Storage Temperature : 25C to 75C

Weight : Approx. 150 g

Connector Type : Terminal Blocks

Working Temperature : 20C to 60C



Back to top