PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1
PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1
PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1
PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1

PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1

PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1 Specification

  • Features
  • Galvanic isolation, compact housing, DIN rail mounting, EMC optimized
  • Connector Type
  • Screw terminals
  • Noise Level
  • Low (optimized for process automation)
  • Cooling Method
  • Natural convection
  • Working Temperature
  • -20C to +60C
  • Rated Power
  • <1 W
  • Application
  • Intrinsically safe signal transmission in hazardous areas
  • Power Supply
  • 24 V DC (nominal)
  • Operating Temperature
  • -20C to +60C
  • Output Current
  • Approx. 250 mA (switching output)
  • Current Range
  • Input: 5 mA
  • Output Type
  • Relay; transistor (switching output)
  • Rated Current
  • Nominal 17 mA (input)
  • Phase
  • Single phase (control signal)
  • Product Type
  • Amplifier Module
  • Output Power
  • <1 W
  • Output Frequency
  • DC signal, switching function
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Reverse polarity protection
  • Efficiency
  • High signal transmission fidelity
  • Material
  • Plastic housing
  • Line Regulation
  • Typical for interface modules
  • Storage Temperature
  • -40C to +80C
  • Weight
  • Approx. 150 g
  • Degree of Protection
  • IP20 (DIN EN 60529)
  • Signal Type
  • Digital input (binary), NAMUR sensor compatible
  • Dimensions
  • 20 mm x 115 mm x 110 mm (W x H x D)
  • Mounting
  • 35 mm DIN rail
  • Explosion Protection
  • II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC (Zone 0/20)
  • Channels
  • 1 channel
  • LED Indicators
  • Power and status indication
  • Response Time
  • <10 ms
 
 

About PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1



The PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1 is a first-rate solution, offering exceptional intrinsically safe signal transmission for hazardous zones (Zone 0/20). With superior explosion protectionII (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIICthis in-demand module runs efficiently on 24 V DC nominal power. Its compact 35 mm DIN rail mounting and advanced galvanic isolation ensure reliable, low-noise process automation. Delivering swift response, it is perfect for NAMUR sensor applications. Add to Cart now for a terrific advance purchase opportunity from Indias leading supplier and trader.

Versatile Applications Across Industries

The KFD2-GU-EX1 amplifier module operates seamlessly on both industrial and commercial surfaces, adapting to diverse application media. Its general-purpose compatibility makes it suitable for signal transmission, process automation, and control in hazardous areas. The module is optimized for digital inputs using NAMUR sensors, supporting broad operational needs without sacrificing safety or performance. Its an ideal choice for sectors demanding superior reliability in intrinsically safe environments.


Reliable Supply and Effortless Delivery

Our supply chain ensures a steady outlay of the KFD2-GU-EX1 amplifier modules. Sample policy allows for prior evaluation before greater investment, ensuring confidence before bulk ordering. Shipped goods are swiftly dispatched, with delivery time tailored to your requirements and location within India. Count on consistent supply ability powered by a robust logistics framework, making your advance purchase streamlined and worry-free.


FAQs of PEPPERL + FUCHS Amplifier Module KFD2-GU-EX1:


Q: How does the PEPPERL + FUCHS KFD2-GU-EX1 module enhance safety in hazardous areas?

A: The module incorporates advanced explosion protection (II [1] G/D), making it suitable for use in Zone 0/20 hazardous environments. Its intrinsically safe design prevents ignition risks and protects surrounding equipment.

Q: What applications is this amplifier module best suited for?

A: The KFD2-GU-EX1 is optimized for intrinsically safe signal transmission and digital input processing, including NAMUR sensors, in process automation, chemical, and petroleum industries.

Q: When can I expect the delivery of my KFD2-GU-EX1 module after placing an order?

A: Once you add the module to your cart and confirm your advance purchase, goods are typically dispatched promptly, with delivery time dependent on your specific location and the current supply chain situation.

Q: Where is the PEPPERL + FUCHS KFD2-GU-EX1 module primarily installed?

A: The module is designed for mounting on 35 mm DIN rails, making it ideal for integration into industrial automation panels and hazardous area control cabinets.

Q: What are the benefits of using this module for digital input signal transmission?

A: Benefits include superior galvanic isolation for signal fidelity, fast response time (<10 ms), reliable operation with low noise, and compatibility with NAMUR sensors, all in a compact, easy-to-install housing.

Q: How is signal integrity maintained by this amplifier module?

A: The module features high signal transmission fidelity, EMC-optimized construction, reverse polarity protection, and natural convection cooling, ensuring consistent and reliable performance in process environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Cooling Method : Natural Air Cooling

Storage Temperature : 25C to +70C

Features : DIN Rail Mount, LED Indicator, ATEX Certified

Connector Type : Screw Terminals

Weight : ~120 g

Product Type : Safety Barrier (Signal Isolator)

PEPPERL+FUCHS KFD2-CRG-EX1

PEPPERL+FUCHS KFD2-CRG-EX1

Cooling Method : Selfcooled / natural convection

Storage Temperature : 25C to +70C

Features : Galvanic isolation, signal amplification, compact design

Connector Type : Pluggable screw terminals

Weight : Approx. 150 g

Product Type : Signal Conditioner / Current Repeater

PEPPERL+FUCHS KFD2-UT-EX1

PEPPERL+FUCHS KFD2-UT-EX1

Cooling Method : Natural Convection

Storage Temperature : 40C to 85C

Features : Intrinsic Safety Barrier Galvanic Isolation

Connector Type : Screw Terminals

Weight : Approx. 150g

Product Type : Signal Conditioner

PEPPERL+FUCHS KG30-H-EX

PEPPERL+FUCHS KG30-H-EX

Cooling Method : Passive

Storage Temperature : 40C to +85C

Features : ATEX Certified, LED Status Indicator

Connector Type : Cable

Weight : Approx. 190g

Product Type : Inductive Sensor



Back to top