PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1
PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1
PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1
PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1

PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1

PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1 Specification

  • Power Supply
  • 24 V DC nominal
  • Rated Power
  • 2 W max
  • Output Current
  • < 2 mA (per channel, intrinsically safe circuit)
  • Output Type
  • Relay contact
  • Cooling Method
  • Natural convection
  • Rated Current
  • < 2 mA
  • Application
  • Signal isolation and amplification in hazardous area instrumentation
  • Operating Temperature
  • -20 C to +60 C
  • Working Temperature
  • -20 C to +60 C
  • Features
  • 1-channel, intrinsically safe, signal conversion, compact design, LED indicators for status
  • Power Factor
  • N/A (DC device)
  • Phase
  • Single Phase
  • Current Range
  • 4 mA to 20 mA input supported
  • Noise Level
  • Low noise signal amplification
  • Connector Type
  • Plug-in screw terminals
  • Product Type
  • Amplifier Module
  • Output Power
  • 2 W
  • Output Frequency
  • Signal frequency up to 10 kHz
  • Input Voltage
  • 20 V DC to 30 V DC
  • Voltage Protection
  • Reverse polarity protection and surge protection
  • Efficiency
  • High efficiency, optimized for intrinsic safety signals
  • Material
  • Plastic enclosure
  • Line Regulation
  • 0.1 %
  • Storage Temperature
  • -40 C to +80 C
  • Weight
  • Approx. 150 g
 
 

About PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1



The PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1 is a first-rate choice for hazardous area instrumentation, setting an unprecedented standard in intrinsic safety signal conversion. With instant checkout and favorable reviews, this featured device is matchless in efficiency and reliability. Certified to rigorous ATEX and IECEx safety standards, it offers robust DIN rail mounting, rapid <10 ms response, and reliable LED status indication. Designed with superior IP20 protection, reverse polarity, and surge protection, its low-noise amplification and compact form make it ideal for modern plant environments. Perfect for signal isolation, it ensures 1,000,000 switching cycles.

Versatile Application and Plant Integration

The KFD2-FSU-EX1 is engineered for seamless signal isolation and amplification in hazardous process plants, including oil, gas, chemical, and pharmaceutical facilities. Its compact design and DIN rail mounting simplify application within control panels. The amplifier supports a wide input current range (420 mA), making it adaptable for various field device configurations. Effortless integration and LED status indicators enhance plant operational safety, while robust construction ensures high reliability across diverse industrial environments.


Supply Ability and Sample Policy Details

PEPPERL + FUCHS ensures unmatched supply ability for the KFD2-FSU-EX1, with reliable packing & dispatch processes to meet project timelines. Customers can estimate delivery schedules based on FOB Port India, enabling flexible drop-off and logistics management. The supplier offers a clear sample policy for evaluation, facilitating smooth procurement and testing. Careful packaging and prompt dispatch guarantee product integrity upon arrival, making it suitable for demanding projects with tight deadlines.


FAQs of PEPPERL + FUCHS Amplifier Module KFD2-FSU-EX1:


Q: How is the KFD2-FSU-EX1 amplifier module installed in industrial facilities?

A: The amplifier module is easily installed using a standard 35 mm DIN rail mount, making it quick to integrate into control panels within hazardous locations.

Q: What unique benefits does the KFD2-FSU-EX1 offer for hazardous area signal isolation?

A: The device provides matchless intrinsic safety, compact DIN rail mounting, and high efficiency, protecting control circuits while isolating and amplifying field device signals.

Q: When should you choose this module for your instrumentation systems?

A: Select the KFD2-FSU-EX1 when your application requires reliable, fast response signal amplification and isolation in potentially explosive or hazardous environments.

Q: Where can the KFD2-FSU-EX1 be commonly used?

A: This amplifier module is ideal for industries such as oil and gas, chemical processing, and pharmaceuticals where hazardous atmospheres necessitate ATEX- and IECEx-certified components.

Q: What is the process for checking the modules operational status?

A: LED indicators on the front panel provide instant status updates: green shows power is on, and yellow indicates the relay is energized, allowing quick operational checks.

Q: How does the KFD2-FSU-EX1 enhance reliability in signal processing?

A: With high-efficiency signal amplification, exceptional voltage protection, and a service life exceeding one million switching cycles, this module ensures consistent, low-noise performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Connector Type : Screw Terminal

Weight : Approximately 150g

Power Supply : 24V DC External Supply

Voltage Protection : Integrated overvoltage and shortcircuit protection

Output Type : Other, Analog/Digital signal barrier

Input Voltage : 24V DC

PEPPERL+FUCHS KFD2-UT2-EX1(10)

PEPPERL+FUCHS KFD2-UT2-EX1(10)

Connector Type : Screw terminals

Weight : Approx. 100g

Power Supply : External DC supply

Voltage Protection : Overvoltage protection

Output Type : Relay output, Other

Input Voltage : 2030V DC

PEPPERL+FUCHS KFD2-STC4-EX1.20

PEPPERL+FUCHS KFD2-STC4-EX1.20

Connector Type : Screw Terminals

Weight : Approx. 150 g

Power Supply : 24 V DC

Voltage Protection : Intrinsic Safe

Output Type : Other, Current Output

Input Voltage : 24 V DC

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Connector Type : Screw Terminal

Weight : Approx. 150 g

Power Supply : External, 24 V DC Nominal

Voltage Protection : Overvoltage and ShortCircuit Protection

Output Type : Other, Isolated Signal Output

Input Voltage : 20 V to 35 V DC



Back to top