PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER
PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

PEPPEL FUCHS BARRIER Specification

  • Cooling Method
  • Natural Air Cooling
  • Output Type
  • Relay Contact/Transistor
  • Application
  • Hazardous Area Signal Isolation (Sensor, Transmitter, Actuator Interface)
  • Output Current
  • up to 60 mA
  • Working Temperature
  • -20C to +60C
  • Rated Power
  • 1 W
  • Power Factor
  • >0.9
  • Rated Current
  • 60 mA
  • Phase
  • Single Phase
  • Operating Temperature
  • -20C to +60C
  • Features
  • DIN Rail Mounting, LED Indicator, Galvanic Isolation
  • Connector Type
  • Screw Terminal
  • Power Supply
  • Terminal connection
  • Current Range
  • 4 mA to 20 mA
  • Noise Level
  • Low (< 30 dB)
  • Product Type
  • Intrinsic Safety Barrier
  • Output Power
  • 750 mW
  • Output Frequency
  • DC
  • Input Voltage
  • 20-30 V DC
  • Voltage Protection
  • Short-circuit and overload protection
  • Efficiency
  • 85%
  • Material
  • Plastic (Housing), Electronic Components
  • Line Regulation
  • < 0.1%
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 150 g
  • Protection Degree
  • IP20
  • Mounting Type
  • DIN Rail (35 mm) Mount
  • Isolation Voltage
  • 250 Vrms
  • Series
  • K-System
  • Response Time
  • < 15 ms
  • Color
  • Green
  • Reverse Polarity Protection
  • Yes
  • Housing Dimension
  • approx. 17.6 mm x 108 mm x 115 mm (W x H x D)
  • Approval
  • ATEX, IECEx, CE
  • Input Signal Type
  • Digital/Analog
 
 

About PEPPEL FUCHS BARRIER



Discover the remarkable PEPPEL FUCHS BARRIER, designed for hazardous area signal isolation with reliable DIN Rail (35 mm) mounting. Now available at a special Price Cut for a Limited Time! This praiseworthy product boasts decorated international approvals (ATEX, IECEx, CE), a rapid < 15 ms response, and robust voltage protection. Personalise your setup with relay contact or transistor output options. Efficient at 85%, the green K-System series ensures remarkable safety and versatility. Act quicklysecure a distinguished solution thats both functional and lauded by industry experts.

Precision Applications & Key Features

The PEPPEL FUCHS BARRIER is primarily used for isolating signals between sensors, transmitters, and actuators in hazardous zones. Its DIN Rail mounting method facilitates straightforward and secure installation. Praiseworthy features include galvanic isolation, short-circuit and overload protection, and a handy LED indicator. With a noise level of less than 30 dB and natural air cooling, this device is engineered for both digital and analog input signals, making it a remarkable and multipurpose interface solution across critical environments.


Payment Terms, Supply Capacity & Certifications

Our asking price for the PEPPEL FUCHS BARRIER is competitively valued, reflecting its praiseworthy international certifications (ATEX, IECEx, CE). Handed Over to clients under flexible payment terms, we guarantee prompt delivery and a secure valuation process. As a leading supplier and trader in India, our supply ability efficiently meets the demands of diverse applications, ensuring decorous compliance with industry standards. Secure your order confidently and benefit from decorated legitimacy in every transaction.


FAQs of PEPPEL FUCHS BARRIER:


Q: How does the PEPPEL FUCHS BARRIER ensure safety in hazardous environments?

A: The PEPPEL FUCHS BARRIER provides galvanic isolation, robust voltage protection (short-circuit and overload), and holds ATEX, IECEx, and CE approvals, ensuring safe operation in hazardous areas.

Q: What are the main usage scenarios for this barrier device?

A: This barrier is designed for isolating signals between sensors, transmitters, and actuator interfaces, particularly in industrial applications within hazardous or potentially explosive environments.

Q: Where can the PEPPEL FUCHS BARRIER be mounted?

A: The device is engineered for easy installation on a 35 mm DIN Rail, which is common in industrial control panels and hazardous area enclosures.

Q: When should I consider using a barrier like this one?

A: You should use this barrier when you require safe isolation and signal transfer in environments where explosive gases or dust may be present, meeting strict industry certification standards.

Q: What is the process for connecting and configuring the barrier?

A: The unit features a screw terminal connector type, making wiring straightforward. It supports both digital and analog signals and includes LED indicators for status monitoring.

Q: What benefits does the LED indicator provide?

A: The built-in LED indicator offers immediate visual feedback on operational status, enabling quick diagnostics and reducing downtime.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PEPPERL + FUCHS Used Materials Category

PEPPERL+FUCHS Z779

PEPPERL+FUCHS Z779

Operating Temperature : 20C to +60C

Input Voltage : 250 V AC/DC max

Connector Type : Screw terminals

Weight : approx. 100 g

Features : Isolated ground, reversible polarity, DINrail mountable

Storage Temperature : 25C to +70C

PEPPERL+FUCHS KHA5-SS1/EX2

PEPPERL+FUCHS KHA5-SS1/EX2

Operating Temperature : 20C to 60C

Input Voltage : 220V AC

Connector Type : Standard Screw Terminal

Weight : 1.2 kg

Features : Explosion Proof Simple Installation Indicator Lights

Storage Temperature : 40C to 80C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Operating Temperature : 20C to +60C

Input Voltage : 20 V DC to 30 V DC

Connector Type : Screw terminals

Weight : About 120 g

Features : LED status indication, compact design, galvanic isolation

Storage Temperature : 25C to +70C

PEPPEL  FUCHS BARRIER

PEPPEL FUCHS BARRIER

Operating Temperature : 20C to +60C

Input Voltage : 24V DC

Connector Type : Screw Terminals

Weight : Approx. 150g

Features : DIN Rail Mounting, LED Status Indication, Intrinsically Safe

Storage Temperature : 40C to +80C



Back to top