OMRON MODULE NC112
OMRON MODULE NC112

OMRON MODULE NC112

OMRON MODULE NC112 Specification

  • Output Type
  • Relay Output
  • Connector Type
  • Screw terminal
  • Phase
  • Single Phase
  • Power Factor
  • >0.85
  • Current Range
  • 0.1A to 2A
  • Application
  • Industrial Automation, PLC Systems, I/O Expansion
  • Output Current
  • 0.1A to 2A
  • Cooling Method
  • Natural Air Cooling
  • Operating Temperature
  • 0C to +55C
  • Features
  • Detachable terminal block, Compact design, Status indicator
  • Rated Power
  • 2.5W
  • Rated Current
  • 2A max
  • Working Temperature
  • 0C to +55C
  • Power Supply
  • External
  • Noise Level
  • 30dB
  • Product Type
  • NC112 MODULE
  • Output Power
  • 2.5W max
  • Output Frequency
  • 50/60 Hz
  • Input Voltage
  • 24V DC
  • Voltage Protection
  • Overvoltage and Undervoltage Protection
  • Efficiency
  • Up to 85%
  • Material
  • Flame-resistant Plastic
  • Line Regulation
  • 0.5%
  • Storage Temperature
  • -25C to +70C
  • Weight
  • 72g
  • Mounting Type
  • DIN Rail Mount
  • Insulation Resistance
  • >20M (500VDC)
  • Communication Interface
  • Parallel Interface
  • Response Time
  • <10ms
  • Protection Level
  • IP20
  • Color
  • Grey
  • Dimensions (W x H x D)
  • 90mm x 35mm x 70mm
  • Compatible Series
  • SYSMAC series
 
 

About OMRON MODULE NC112



Experience the ultimate in industrial automation with the OMRON MODULE NC112, now available at a fresh special rate with instant checkout options. This opulent module, with a commanding DIN rail mount, features a parallel communication interface and offers robust overvoltage and undervoltage protection. Its swift <10ms response time, premium flame-resistant build, and compact dimensions (90mm x 35mm x 70mm) ensure seamless integration and reliability. With efficiency up to 85%, a detachable terminal block, and SYSMAC series compatibility, this sophisticated relay output solution stands as the pinnacle for professionals seeking high performance and safety in I/O expansion or PLC systems.

Optimized Use and Versatile Application

Designed for seamless integration, the OMRON MODULE NC112 is ideal for PLC systems and industrial automation setups. The module utilizes a parallel communication interface and is mounted securely on DIN rails. Its adaptable usage caters to I/O expansion and real-time control, making it an invaluable addition to any automation framework. The device is suited for industrial control panels using 24V DC and operates efficiently in varied environments, ensuring reliable performance for a wide range of application media.


FOB Port, Sample Policy, and Payment Terms

Benefit from efficient outlay management and streamlined transport services as you order the OMRON MODULE NC112 through our trusted networks. We provide clear sample policies and flexible payment terms to enhance convenience throughout your transaction. Your order completion is handled with utmost care and punctuality, ensuring the module reaches your specified FOB port in pristine condition. This meticulous handling empowers smooth procurement and helps maximize your operational uptime and investment certainty.


FAQs of OMRON MODULE NC112:


Q: How does the OMRON MODULE NC112 enhance industrial automation systems?

A: The NC112 improves system reliability and responsiveness through its fast response time (<10ms), robust IP20 protection, and seamless integration with SYSMAC series PLCs, making it ideal for real-time control and I/O expansion.

Q: What is the recommended process for installation and setup?

A: To install, secure the module onto a DIN rail, connect via screw terminals using appropriately rated cables, and configure the parallel interface for your specific SYSMAC automation environment. Ensure proper input voltage and check for secure fixture before power-up.

Q: When should the NC112 be used in an automation setup?

A: It is best used when expanding I/O capacity, interfacing new equipment, or requiring compact and reliable relay outputs within existing PLC systems. Its high efficiency and wide operating temperature range make it suitable for various timings and industrial demands.

Q: Where can the OMRON MODULE NC112 be sourced in India?

A: This module is available through authorized OMRON suppliers and traders across India, ensuring genuine products and proper technical support for your automation needs.

Q: What benefits does the detachable terminal block provide?

A: The detachable terminal block simplifies maintenance and wiring changes. It allows for quick disconnection during servicing or upgrades, reducing system downtime and increasing efficiency in fast-paced environments.

Q: How does the voltage protection feature work in practice?

A: The overvoltage and undervoltage protection actively monitors power input, automatically safeguarding the module and connected devices from hazardous voltage fluctuations, thus prolonging system lifespan and preventing damage.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in OMRON Used PLC SERVO DRIVE Category

SIEIDrive  AGL50, GEFRAN

SIEIDrive AGL50, GEFRAN

Working Temperature : 0C to 45C

Weight : 3.5kg

Power Supply : Industrial Power Supply

Material : Plastic and Metal

Operating Temperature : 0C to 45C

Cooling Method : Air Cooling

OMRON POWER SUPPLY C200HW-PA204

OMRON POWER SUPPLY C200HW-PA204

Working Temperature : 0C to 55C

Weight : Approximately 1.2kg

Power Supply : OMRON POWER SUPPLY C200HWPA204

Material : Metal

Operating Temperature : 0C to 55C

Cooling Method : Natural Cooling

OMRON PLC CP1L-M40DR-D

OMRON PLC CP1L-M40DR-D

Working Temperature : 0C to 55C

Weight : Approximately 0.8 kg

Power Supply : 24V DC

Material : Plastic and Metal

Operating Temperature : 0C to 55C

Cooling Method : None

OMRON INPUT UNIT MODULE

OMRON INPUT UNIT MODULE

Working Temperature : 10C to 55C

Weight : Approximately 150g

Power Supply : 24 VDC

Material : Plastic Metal

Operating Temperature : 10C to 55C

Cooling Method : None (modulelevel cooling not required)



Back to top