LEM LF 510-S/SPA1 CURRENT SENSOR Specification

  • Phase
  • Single Phase
  • Power Supply
  • 15 V DC 5%
  • Noise Level
  • Output Type
  • Analog (Voltage, typically 4 V/A, or Current output)
  • Connector Type
  • Screw terminals
  • Current Range
  • 510 A
  • Output Current
  • Rated output: 500 mA max
  • Application
  • Industrial Drives, Power Supplies, Battery Monitoring, Renewable Energy
  • Features
  • High accuracy, Fast response time, Galvanic isolation, Compact design
  • Working Temperature
  • -40C to +85C
  • Rated Current
  • 510 A
  • Operating Temperature
  • -40C to +85C
  • Cooling Method
  • Natural air cooling
  • Power Factor
  • Rated Power
  • Product Type
  • Closed Loop Hall Effect Current Sensor
  • Output Power
  • Output Frequency
  • DC to 150 kHz
  • Input Voltage
  • Up to 725 A (primary current)
  • Voltage Protection
  • Insulation voltage 4.3 kV (50Hz/1min)
  • Efficiency
  • Material
  • Plastic Housing, Copper Windings, Magnetic Core
  • Line Regulation
  • Storage Temperature
  • -40C to +90C
  • Weight
  • Approx. 500 g
 
 

About LEM LF 510-S/SPA1 CURRENT SENSOR



The LEM LF 510-S/SPA1 CURRENT SENSOR has garnered Favorable Reviews for its exhilarating performance in demanding industrial scenarios. Delivering an Astounding combination of high accuracy (0.9%) and a Sizzling fast response time (<1 s), this sensor stands out with its Majestic panel-mount design and galvanic isolation. The Unbeatable Price makes it a Valorous choice, ensuring optimal safety with over 8 mm creepage and a robust 4.3 kV dielectric strength. Ideal for power supplies, battery monitoring, and renewable energy applications in India.

Why Choose LEM LF 510-S/SPA1 CURRENT SENSOR?

This current sensor dazzles with its primary competitive advantages: high precision, fast response, and rugged industrial insulation (CAT III). Its compact profile is perfect for panel-mounted usage using screw terminals. Suited mainly for industrial drives, power supplies, and renewable energy systems, the LEM LF 510-S/SPA1 provides reliable analog output for demanding single-phase operations, especially for users prioritizing efficiency and accuracy in their energy monitoring requirements.


LEM LF 510-S/SPA1 Sensor: Prompt Delivery and Premium Packaging

Expect Premium packing standards, ensuring the products Majestic quality remains intact during transit. The dispatching process is streamlined for a fast rate, typically reaching Indias main domestic markets with minimal delay. Each sensor is securely packaged to withstand handling, with timely delivery as a hallmark of our service. Clients can count on responsive after-sales support, making the purchasing experience seamless from order placement to installation.


FAQs of LEM LF 510-S/SPA1 CURRENT SENSOR:


Q: How accurate is the LEM LF 510-S/SPA1 CURRENT SENSOR in industrial applications?

A: The sensor offers precision with an accuracy of 0.9% at nominal current, making it suitable for critical monitoring tasks in high-demand environments.

Q: What is the typical response time of this sensor?

A: It boasts a sizzling fast response time of less than 1 s, ensuring prompt and reliable current detection even during rapid load changes.

Q: Where can I mount the LF 510-S/SPA1 sensor?

A: The sensor is designed for panel mounting and is secured with four screws, providing stable installation in control panels or enclosures.

Q: What benefits does the high insulation voltage provide?

A: With an insulation voltage of 4.3 kV AC and creepage greater than 8 mm, the sensor ensures robust safety and galvanic isolation between primary and secondary circuits.

Q: How is the LEM LF 510-S/SPA1 delivered and packaged?

A: It is delivered with premium packaging, carefully secured for protection during shipment to main domestic markets across India, ensuring the product arrives intact and ready for use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in LEM Category

LEM LF 305-S CURRENT TRANSDUCER

LEM LF 305-S CURRENT TRANSDUCER

Minimum Order Quantity : 1 Piece

LEM LF505-S/SP13 CURRENT SENSOR

LEM LF505-S/SP13 CURRENT SENSOR

Minimum Order Quantity : 1 Piece

LEM LF 505-S/SP27 CURRENT TRANSDUCER

LEM LF 505-S/SP27 CURRENT TRANSDUCER

Minimum Order Quantity : 1 Piece



Back to top