GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX
GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX

GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX Specification

  • Features
  • Differential, Overcurrent, Over/Under Voltage, Remote Ethernet, Modbus, DNP3 Communication
  • Noise Level
  • Silent (Electro-mechanical relay operation only)
  • Cooling Method
  • Self-cooled, Passive Air
  • Output Current
  • Configurable (Dependent on Model and Application)
  • Application
  • Transformer Protection for Utility and Industrial Power Systems
  • Working Temperature
  • -40C to +70C
  • Output Type
  • Digital Protection Relay Outputs
  • Rated Power
  • Depend on transformer rating
  • Phase
  • Three Phase
  • Current Range
  • Configurable via CT Inputs
  • Power Supply
  • Universal AC/DC Input (Range: see Input Voltage)
  • Rated Current
  • As per CT sizing and configuration
  • Power Factor
  • NA (Relay device, not power conversion)
  • Connector Type
  • Terminal Block, DB9, RJ45 (Ethernet)
  • Operating Temperature
  • -40C to +70C
  • Product Type
  • Transformer Protection System
  • Output Power
  • Configurable / NA
  • Output Frequency
  • 50/60 Hz Compatible
  • Input Voltage
  • 18-80 VDC / 110-250 VDC (Range depends on model options)
  • Voltage Protection
  • Provides transformer protection including differential, overcurrent, and voltage restraint
  • Efficiency
  • High Efficiency (Optimized for industrial utility applications)
  • Material
  • Industrial Grade Polycarbonate, Metal Housing
  • Line Regulation
  • Precision Digital Monitoring
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 4.5 kg
  • Dimensions
  • 278 mm x 166 mm x 200 mm (W x H x D)
  • Communication Ports
  • RS232, RS485, Ethernet, IEC 61850, Modbus, DNP3
  • Protection Functions
  • Restricted Earth Fault, Transformer Differential, Overcurrent, Thermal Protection, Breaker Failure, Volts/Hertz Protection
  • Mounting Type
  • Panel/Flush Mounting
  • Event Recorder
  • Multiple Events/Up to 1024 cycles
  • Firmware Upgrade
  • Field Upgradable
  • Alarm Outputs
  • Configurable, Relay Outputs
  • HMI
  • Front Push Buttons and Display
  • Display Type
  • Graphical LCD with Menu Navigation
  • Model Number
  • T60N34HKHF8NH6DM8LP67UXXWXX
 
 

About GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX



Discover the exclusive GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX, engineered for first-string reliability at a reduced price. This imposing solution brings unbeatable transformer protection through advanced differential, overcurrent, and volts/hertz safeguarding. Featuring a graphical LCD with intuitive menu navigation, robust communication ports (Ethernet, RS232, RS485, IEC 61850, Modbus, DNP3), and configurable relay outputs, it ensures seamless integration and protection management. Field-upgradable firmware and industrial-grade build provide increased durability. Take advantage of this offer to optimize your utility or industrial power systemmaximum protection, minimum complexity.

Versatile Applications and Superior Benefits

The GE MULTILIN T60 is suitable for both industrial and utility power systems, making it ideal for environments demanding robust transformer protection. Its extensive protection functions and communication options are advantageous for substations, power plants, and critical infrastructure. The main advantage lies in its field-upgradable firmware and flexible configuration, which allow for continuous improvement and adaptation. This versatility makes the T60 a preferred choice for engineers seeking reliability and adaptability.


Export Markets, Premium Packaging & Domestic Reach

The GE MULTILIN T60 ships to premium export markets across Asia, the Middle East, and Africa, meeting stringent international standards. Packaged with precision to safeguard shipped goods, this product arrives ready for demanding installations. Its list price reflects the high-quality engineering and performance. Catering to major Indian markets, the T60 remains a sought-after solution for domestic suppliers, traders, and utilities aiming to upgrade their transformer protection with proven technology.


FAQs of GE MULTILIN T60 TRANSFORMER PROTECTION SYSTEM T60N34HKHF8NH6DM8LP67UXXWXX:


Q: How does the GE MULTILIN T60 provide transformer protection?

A: The GE MULTILIN T60 offers transformer protection through features such as restricted earth fault, transformer differential, overcurrent, thermal protection, and volts/hertz protection, ensuring safety and reliability for transformer assets in industrial and utility settings.

Q: What communication interfaces are included with this device?

A: This system includes RS232, RS485, Ethernet, IEC 61850, Modbus, and DNP3 communication ports, facilitating seamless integration and remote monitoring within modern power system infrastructures.

Q: Where can the GE MULTILIN T60 be mounted?

A: The T60 is designed for panel or flush mounting, accommodating various installation preferences common in substations and industrial environments.

Q: What are the advantages of field-upgradable firmware in the T60?

A: Field-upgradable firmware enables users to update the device with new features or security enhancements on-site, extending the life and adaptability of the protection system without replacing hardware.

Q: How is the GE MULTILIN T60 packaged for export shipments?

A: The T60 is packaged securely using industry-standard materials, ensuring that shipped goods remain protected from damage during transit to both domestic and international destinations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

SEL 071001G1G3G72810310 MOTOR PROTECTION RELAY

SEL 071001G1G3G72810310 MOTOR PROTECTION RELAY

Application : Motor Protection, Industrial Automation

Working Temperature : 40C to +75C

Weight : Approx. 1.8 kg

Features : Comprehensive motor protection, metering, communications, diagnostics, configurable I/O

Cooling Method : Air Cooled

Current Range : 1720 A (Configurable)

GE MULTILIN 369 MOTOR MANAGEMENT RELAY 1853-4042

GE MULTILIN 369 MOTOR MANAGEMENT RELAY 1853-4042

Application : Motor Protection, Industrial Automation, Fault Diagnostics

Working Temperature : 25C to +55C

Weight : Approx. 2.5 Kg

Features : Large LCD Display, Drawout Case, RS485 & RS232, Programmable Inputs/Outputs, Fault Recording

Cooling Method : Passive Cooling

Current Range : 1A to 10A (configurable)

ABB REX521GHHGSH02G RELAYS (REX521)

ABB REX521GHHGSH02G RELAYS (REX521)

Application : Feeder Protection, Industrial Power Systems, Utility Automation

Working Temperature : 10C to +55C

Weight : Approx. 4.5 kg

Features : MultiFunction Protection, Communication Port, SelfDiagnostics

Cooling Method : Natural Air Cooling

Current Range : 1A / 5A Nominal (Configurable)

SIEMENS 7SR4502-1JB20-1AAD/EE RELAY

SIEMENS 7SR4502-1JB20-1AAD/EE RELAY

Application : Feeder and transformer protection in medium voltage distribution networks

Working Temperature : 25C to +60C

Weight : Approx. 2.5 kg

Features : IEC 61850/ANSI/Modbus, LCD display, 4 binary inputs/outputs, configurable LEDs, event/fault recording

Cooling Method : Passive (natural convection)

Current Range : 1 A / 5 A (programmable via CT input)



Back to top