GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER
GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER
GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER
GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER
GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER
GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER

GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER

MOQ : 1 Piece

GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER Specification

  • Features
  • Harmonic Analysis up to 31st, Real-Time Monitoring, Event Logging, Disturbance Recording, User Programmable
  • Connector Type
  • Screw Terminal
  • Operating Temperature
  • -20C to +60C
  • Power Factor
  • True RMS Measurement, Power Factor monitoring
  • Cooling Method
  • Natural Air Cooling
  • Application
  • Power distribution networks, Substations, Industrial automation
  • Phase
  • Three Phase
  • Working Temperature
  • -20C to +60C
  • Rated Current
  • 1A or 5A (Programmable)
  • Output Type
  • Digital (RS485, RS232), Analog (optional)
  • Power Supply
  • Universal AC/DC supply
  • Current Range
  • 1A/5A (programmable)
  • Product Type
  • Power Quality Meter
  • Output Frequency
  • 50/60 Hz
  • Input Voltage
  • 120/230 VAC, 110/220 VDC
  • Voltage Protection
  • Over/Under Voltage Protection
  • Material
  • High Impact Plastic Enclosure
  • Storage Temperature
  • -40C to +70C
  • Weight
  • Approx. 1.3 kg
  • Mounting Type
  • Panel Mount
  • Relay Outputs
  • Up to 2 Programmable Relay Outputs (for alarms, control)
  • Dimensions
  • 144mm x 144mm x 137mm
  • Data Storage
  • Internal Non-Volatile Memory
  • Harmonics Measurement
  • Up to 31st Harmonic
  • Input Frequency Range
  • 4565 Hz
  • Enclosure Protection
  • IP54 (front panel)
  • Measurement Parameters
  • Voltage, Current, Power, Power Factor, Frequency, Harmonics, Energy
  • Time Synchronization
  • RTC with Battery Backup
  • Communication Protocols
  • Modbus RTU, DNP3, RS485, RS232
  • Compliance Standards
  • IEC 61010, IEC 61326
  • Event Recording
  • Yes, Programmable Recording of Power Quality Events
  • Display
  • Large, High-Contrast, Backlit LCD Display
  • Accuracy
  • Class 0.2S for Energy, Class 0.2 for Voltage/Current
 
 

About GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER



Take advantage of the sizzling performance offered by the GE MULTILIN PQM-T20-C-A PQM Power Quality Metera first-rate solution tailored for power monitoring in critical environments. This potent device boasts a large, high-contrast backlit LCD, delivering unparalleled accuracy (Class 0.2S for energy, Class 0.2 for voltage/current) and comprehensive harmonic analysis up to the 31st harmonic. Grab this reliable meter for real-time monitoring, power quality event recording, and true RMS measurement. Its robust, high-impact plastic enclosure, advanced communication interfaces, and versatile mounting make it ideal for substations, industrial automation, and power distribution networks.

Essential Power Quality Monitoring Across Multiple Application Areas

GE MULTILIN PQM-T20-C-A PQM Power Quality Meter is designed to excel in power distribution networks, substations, and industrial automation settings. With versatile plant application capabilities, it is perfectly suited for monitoring key electrical parameters and improving site efficiency. Its advanced features make it indispensable for environments where power reliability and quality are paramount, ensuring operational stability for critical infrastructure and automated industrial plants across varied application sites.


Domestic Market Delivery, Sample Policy, and Transport Services

The GE MULTILIN PQM-T20-C-A is available throughout Indias main domestic markets, ensuring broad accessibility. Sample policies can be discussed to help organizations evaluate its suitability. With reliable transport services and options for express shipping, your unit is delivered swiftly and safely. Standard delivery timelines are efficiently managed to suit project schedules, guaranteeing on-time arrival and minimal disruption to your operations.


FAQs of GE MULTILIN PQM-T20-C-A PQM POWER QUALITY METER:


Q: How does the GE MULTILIN PQM-T20-C-A enhance power quality monitoring in industrial applications?

A: The GE MULTILIN PQM-T20-C-A offers real-time monitoring and programmable event logging, enabling industrial users to detect and rectify power quality issues promptly, thereby improving system reliability and operational efficiency.

Q: What measurement parameters does this meter support for comprehensive monitoring?

A: It measures voltage, current, power, power factor, frequency, harmonics (up to the 31st), and energy, covering essential data points for power quality analysis and system optimization.

Q: Where can this power quality meter be effectively utilised?

A: It is ideally utilised in power distribution networks, substations, and industrial automation facilities, especially where high accuracy and detailed event recording are required.

Q: What is the process for installing and configuring the PQM-T20-C-A on-site?

A: Installation involves panel mounting, wiring via screw terminals, and configuration through its user-friendly LCD interface. Programming options allow customization for event logging and alarm outputs to match your specific site requirements.

Q: What are the main benefits of its advanced communication protocols?

A: The inclusion of Modbus RTU, DNP3, RS485, and RS232 allows seamless integration into modern SCADA, automation, and monitoring systems, enhancing data accessibility and remote system control.

Q: When are samples or demo units available for evaluation?

A: Samples or demo units may be available upon request and subject to the suppliers sample policy, allowing clients to assess the meters capabilities before full deployment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in GE METER Category

GE MULTILIN PQMII-T20-C-A PQMII POWER QUALITY METER

GE MULTILIN PQMII-T20-C-A PQMII POWER QUALITY METER

Minimum Order Quantity : 1 Piece

Storage Temperature : 40C to +85C

Input Voltage : 100240VAC, 50/60 Hz

Rated Current : 1A/5A (Configurable)

Output Type : Other, Digital Signal Output

GE MULTILIN PL5500 C METER

GE MULTILIN PL5500 C METER

Minimum Order Quantity : 1 Piece

Storage Temperature : 25C to +70C

Input Voltage : 57V220V AC, 100V480V AC

Rated Current : 1A/5A

Output Type : Other, Digital Display

GE MULTILIN PL5500 D METER

GE MULTILIN PL5500 D METER

Minimum Order Quantity : 1 Piece

Storage Temperature : 10C to +70C

Input Voltage : 90 270V AC/DC

Rated Current : 5A (standard), 1A (optional)

Output Type : Other, Display LCD

GE MULTILIN PQM-T20-A PQM POWER QUALITY METER

GE MULTILIN PQM-T20-A PQM POWER QUALITY METER

Minimum Order Quantity : 1 Piece

Storage Temperature : 20C to +70C

Input Voltage : 85265 VAC / 100300 VDC

Rated Current : 1A/5A Nominal Inputs

Output Type : Other, RS485 Serial, Digital Outputs