  • Rated Operation Voltage
  • 110 - 240 V AC/DC
  • Connectivity Type
  • RS485 Modbus
  • Thickness
  • Standard Panel Mount (as per enclosure)
  • Protection Class
  • Class II
  • Rated Current
  • 5A
  • Protection Level
  • IP54
  • Components
  • Digital Meter, IO Modules
  • Operating Voltage
  • 110 - 240 V
  • Cover Material
  • Polycarbonate
  • Way
  • Panel Meter
  • Control System
  • Embedded Microprocessor
  • Current Rating
  • 5A
  • Features
  • Multifunction Measurement, Event Logging, Communication Capabilities
  • Rated Insulation Voltage
  • 600V
  • Panel Type
  • DIN Panel Mount
  • Base Material
  • Polycarbonate
  • Cabinet Material
  • Polycarbonate
  • Cooling System
  • Passive
  • Product Type
  • Power Metering System
  • Material
  • Industrial Grade Plastic / Metal (according to datasheet)
  • Surface Finish
  • Textured
  • Standard
  • IEC/EN 62053-22
  • Surface Color
  • Grey
  • Rated Voltage
  • 110 - 240 V AC/DC
  • Frequency (MHz)
  • 50/60 Hz
  • Maximum Output Current
  • 5A
  • Dimension (L*W*H)
  • 96 x 96 x 80 mm
  • Application
  • Industrial electrical measurement and monitoring
  • IP Rating
  • Ip54
  • Display Type
  • Digital LCD
  • Firmware Upgradable
  • Yes
  • Communication Port
  • RS485 (standard), Optional Ethernet
  • Alarm Output
  • Configurable Digital Output
  • Power Consumption
  • < 10VA
  • Event Logging
  • 256 Events
  • Dimensions (Cutout)
  • 92 x 92 mm
  • Storage Temperature Range
  • -25°C to +70°C
  • Operating Temperature Range
  • -10°C to +55°C
  • Accuracy Class
  • Class 0.5S (Energy Measurement)
  • LED Indication
  • Status & Alarm
  • Measurement Parameters
  • Voltage, Current, Power, Frequency, Power Factor, Energy
  • Mounting Type
  • Flush Panel Mount
  • Weight
  • Approx. 0.5 kg
  • Humidity
  • <95% RH (non-condensing)
 
 

About GE MULTILIN EMP 5500P POWER METERING SYSTEM PL5500 IO D



Grab the GE MULTILIN EMP 5500P POWER METERING SYSTEM PL5500 IO D for ace performance in industrial power monitoring. This sizzling metering solution boasts superb accuracy (Class 0.5S) for trustworthy energy measurements. Its crowning features include flush panel mounting, flexible communication via RS485, and optional Ethernet for seamless integration. With digital LCD display, event logging (256 events), and robust IP54 protection, it is crafted for demanding environments. Order now and experience unmatched reliability and multi-parameter trackingall encased in a textured, grey industrial-grade panel.

Applications & Versatility of GE MULTILIN EMP 5500P

The GE MULTILIN EMP 5500P excels in a diverse range of industrial applications, particularly for energy management and monitoring. It is ideal for power distribution panels, electrical substations, commercial buildings, and factory automation systems. Whether for general use or highly specific energy audits, its crowning versatility and robust design make it the ace choice for facility managers and engineers seeking comprehensive, accurate real-time data across diverse application areas.


Payment Terms & Fast Delivery for GE MULTILIN EMP 5500P

We cater to the export market with flexible payment terms tailored to your organizational needs. Goods transport is swift and secure, ensuring quick dispatch to your location anywhere in India. Delivery time is minimized through efficient logistics networks, promoting timely receipt of your order. Sample units may be available on request, giving you confidence before committing to bulk purchases. Partner with us for seamless procurement and prompt service on the GE MULTILIN EMP 5500P.


FAQs of GE MULTILIN EMP 5500P POWER METERING SYSTEM PL5500 IO D:


Q: How does the GE MULTILIN EMP 5500P ensure measurement precision?

A: The system features superb Class 0.5S accuracy for energy measurement, ensuring reliable and precise monitoring of voltage, current, power, frequency, and energy parameters in industrial environments.

Q: What industries commonly use the GE MULTILIN EMP 5500P?

A: This power metering system is a crowning solution for electrical substations, manufacturing facilities, commercial buildings, and any industrial area requiring stringent energy monitoring and management.

Q: When is event logging particularly beneficial in this system?

A: Event logging, which records up to 256 events, proves invaluable when you need to analyze operational history, detect faults, or enhance compliance and energy auditing processes within your facility.

Q: Where can the GE MULTILIN EMP 5500P be installed?

A: The ace design allows for flush panel mounting in DIN panel meters or switchboards, perfectly suiting both new installations and retrofits in demanding industrial and commercial environments.

Q: What is the process for upgrading the firmware on this unit?

A: Firmware is upgradable via the communication ports, allowing users to apply updates effortlessly, ensuring ongoing compatibility and access to enhanced features.

Q: How does the IO D model facilitate communication and control?

A: It features RS485 Modbus connectivity as standard and an optional Ethernet interface, enabling seamless integration and remote monitoring or control within existing systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Power metering system Category

PQMII-T20-CA Power Quality Monitor General Electric

PQMII-T20-CA Power Quality Monitor General Electric

Protection Level : Other, Panel IP54, Terminal IP20

Protection Class : Class I

Rated Current : 1A/5A (Selectable per CT)

Components : Internal memory, metering circuitry, voltage and current input terminals

Rated Voltage : 530 V AC (Phase to Phase), 300 V AC (Phase to Neutral)

Maximum Output Current : 5A



Back to top