GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX
GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX

GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX

GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX Specification

  • Operating Temperature
  • -40C to +60C
  • Power Supply
  • Dual Range AC/DC
  • Noise Level
  • Low, EMI Suppressed
  • Output Current
  • Configurable Digital/Analog Outputs
  • Rated Power
  • Dependent on Application (Protection Relay)
  • Features
  • Multiple Protocols (IEC61850, DNP3, Modbus), Large LCD Display, Advanced Diagnostics, Event Recorder
  • Connector Type
  • Plug-in Terminal Blocks
  • Cooling Method
  • Natural Cooling
  • Phase
  • Three Phase
  • Rated Current
  • Configurable per Application
  • Working Temperature
  • -40C to +60C
  • Application
  • Breaker Protection, Feeder Management, Substation Automation
  • Output Type
  • Relay Outputs
  • Current Range
  • Programmable, up to 5A / 1A Secondary CT
  • Product Type
  • Breaker Protection System
  • Output Frequency
  • 50/60 Hz (Universal)
  • Input Voltage
  • 24-250 VDC / 48-240 VAC
  • Voltage Protection
  • Over/Under Voltage Protection
  • Efficiency
  • High (Industrial Grade)
  • Material
  • Rugged Industrial Enclosure
  • Line Regulation
  • Automatic Line Sensing
  • Storage Temperature
  • -40C to +85C
  • Weight
  • 4.5 kg (approximate)
  • Display Type
  • Plain Text LCD with Backlighting
  • User Interface
  • Front Panel Keypad and LCD
  • Mounting Type
  • Panel Mount / 19" Rack Mount
  • Digital Outputs
  • 16 (standard)
  • Time Synchronization
  • SNTP (Simple Network Time Protocol)
  • Trip Output Contacts
  • 6 programmable output relays
  • Protection Functions
  • Breaker Failure, Sensitive Earth Fault, Overcurrent, Undercurrent, Directional Protection
  • Breaker Control
  • Integrated with Remote/Local Modes
  • Event Storage
  • Records 512 events with timestamp
  • Firmware Upgradability
  • Field Upgradable Firmware
  • Communication Ports
  • RS232, RS485, Ethernet
  • Digital Inputs
  • 16 (standard)
  • Dimensions
  • 246mm (W) x 174mm (H) x 170mm (D)
 
 

About GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX



Experience the acclaimed GE MULTILIN C60 BREAKER PROTECTION SYSTEM C60J03HKF8LH6UM6UPXXUXXWXX, engineered for ultimate reliability and splendid performance in substation automation. Get instant savings through its advanced protective functions, including breaker failure and sensitive earth fault protection. The grand plain text LCD with backlighting, intuitive keypad, and robust RS232, RS485, and Ethernet communication ensure seamless control. Equipped with 6 programmable output relays, industry-leading event storage, and field-upgradable firmware, this system is designed for precise, industrial-grade efficiency. Ideal for demanding power management, its rugged enclosure and low noise EMI-suppressed operation promise lasting performance and safety.

Perfect Fit for Diverse Applications

The GE MULTILIN C60 BREAKER PROTECTION SYSTEM is superbly suitable for breaker protection, feeder management, and substation automation on panel or 19" rack mounting surfaces. Its rugged industrial enclosure and universal voltage compatibility make it versatile for numerous power scenarios. Advanced features such as programmable relays, 512-event recorder, SNTP synchronization, and user-friendly front panel keypad elevate operational flexibility, ensuring splendid reliability and control for industrial applications across demanding environments.


Certifications, Payment, and Market Reach

Certified to global standards and supporting multiple communication protocols, the GE MULTILIN C60 system benefits industries worldwide. Sale price options are flexible, and payment terms suit both immediate and bulk orders. Available for export across main markets in India and beyond, customers enjoy elegant transportation solutions, including express shipping for urgent requirements. Depend on this grand system for streamlined installation and reliable protection in a wide variety of industrial applications.


FAQs of GE MULTILIN C60 BREAKER PROTECTION SYSTEAM C60J03HKF8LH6UM6UPXXUXXWXX:


Q: How does the GE MULTILIN C60 breaker protection system enhance operational safety?

A: The C60 system provides comprehensive protection functions like breaker failure, sensitive earth fault, overcurrent, and undercurrent, ensuring circuits operate within safe parameters and minimizing downtime during faults.

Q: What surfaces or locations is this protection system suitable for use on?

A: It is designed for both panel mount and 19-inch rack mount installations, making it adaptable to diverse application surfaces in substations, industrial plants, and utility settings.

Q: How can users benefit from the event recorder feature?

A: The system records up to 512 events with timestamps, enabling users to review, analyze, and respond effectively to past incidents for enhanced diagnostics and maintenance efficiency.

Q: Where can this protection system be exported or delivered?

A: The GE MULTILIN C60 is available for export to major markets, especially across India, and can be delivered via express shipping to meet urgent customer requirements.

Q: What payment terms are available for purchasing the GE MULTILIN C60?

A: Customers can choose flexible payment options suitable for their needs, whether for immediate stock, bulk orders, or scheduled deliveries.

Q: What makes the user interface of the C60 system advanced?

A: The system features a grand plain text LCD with backlighting and a convenient front panel keypad, enabling straightforward configuration, local control, and fast access to diagnostics.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

Input Voltage : 24250 V AC/DC

Output Type : Other, Relay Contact

Application : Power System Protection, Industrial Automation, Utility Substations

Current Range : 1 A / 5 A nominal (configurable inputs)

Voltage Protection : Under/Overvoltage, Phase Loss, Frequency

Connector Type : Screw terminals

SIEMENS 7SJ6211-6EB92-1FE0/FF OVERCURRENT PROTECTION AND CONTROL RELAY

SIEMENS 7SJ6211-6EB92-1FE0/FF OVERCURRENT PROTECTION AND CONTROL RELAY

Input Voltage : 80265 V AC/DC

Output Type : Other, Relay Output

Application : Feeder, Transformer, Motor, and Generator Protection

Current Range : Configurable Based on CT Input

Voltage Protection : Integrated Overvoltage and Undervoltage Protection

Connector Type : Screw Terminal

SIEMENS 7SR2203-2MA77-0CA0/DD RELAY

SIEMENS 7SR2203-2MA77-0CA0/DD RELAY

Input Voltage : 110 230 V AC/DC

Output Type : Other, Relay Contacts (Trip and Alarm Outputs)

Application : Protection of Transformers, Feeders, and Power Distribution Systems

Current Range : 1A or 5A CT Secondary (Selectable)

Voltage Protection : Overvoltage and Undervoltage Protection

Connector Type : Screw Terminal Connectors

SIEMENS SIPROTEC 6MD86 RELAY

SIEMENS SIPROTEC 6MD86 RELAY

Input Voltage : DC 24 V, 48 V, 60 V, 110 V, 125 V, 220 V (typ. ranges as per order code)

Output Type : Other, Configurable digital, analog, and communication outputs

Application : Busbar protection in substations and industrial power systems

Current Range : Up to 1000 A (sensor dependent)

Voltage Protection : Busbar differential protection, lowimpedance principle

Connector Type : Plugin terminal blocks



Back to top