EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE
EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE

EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE

MOQ : 1 Piece

EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE Specification

  • Connector Type
  • Removable terminal block
  • Features
  • 2-channel universal analog output, software configurable, removable terminal blocks, LED status indicators
  • Rated Current
  • Up to 20mA per channel
  • Current Range
  • 0 to 20mA, 4 to 20mA
  • Application
  • Industrial Automation, Process Control Systems
  • Noise Level
  • < 1 mVrms
  • Operating Temperature
  • 0 to 55C
  • Power Supply
  • Powered via main 2500 system backplane
  • Output Type
  • Analog, Universal (Configurable for Voltage or Current)
  • Output Current
  • 0 to 20mA, 4 to 20mA (configurable)
  • Cooling Method
  • Natural convection
  • Working Temperature
  • 0 to 55C
  • Product Type
  • Output Module
  • Output Power
  • Not Applicable (Signal Output Module)
  • Output Frequency
  • DC/Configurable (Analog Output)
  • Input Voltage
  • Not Applicable (Signal Output Module)
  • Voltage Protection
  • Internal circuit protection provided
  • Efficiency
  • High conversion efficiency for analog output signals
  • Material
  • Industrial-grade, flame-retardant polymer, PCB board
  • Line Regulation
  • 0.1% of output span
  • Storage Temperature
  • -20 to 70C
  • Weight
  • Approx. 120 g
  • Output Resolution
  • 16 bits
  • Compliance Standards
  • CE Marked, EMC & RoHS compliant
  • Isolation
  • Channel-to-channel and channel-to-bus isolation
  • Diagnostic Indicators
  • LED channel status, module fault indication
  • Number of Output Channels
  • 2 (independent, configurable)
  • Factory Calibration
  • Yes, with trimming option
  • Mounting Type
  • DIN rail (modular Eurotherm 2500 system)
  • Model Number
  • 2500M / AO2UNIV
  • Addressing
  • Software configurable address
  • Output Signal Range
  • 0-10VDC, 2-10VDC, ±10VDC, 0-20mA, 4-20mA
  • Response Time
  • < 10 ms
  • Module Dimensions
  • Approx. 125 mm x 22.5 mm x 120 mm
 
 

About EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE



The EUROTHERM 2500M / AO2UNIV output module is a highlighted solution for pivotal industrial automation and process control needs. Featuring two scarce, independent, and configurable output channels, this top-notch module delivers praiseworthy signal flexibility, supporting 0-10VDC, 2-10VDC, 10VDC, 0-20mA, and 4-20mA ranges. Its robust channel-to-channel isolation maximizes reliability and operational safety. Fast response times (<10 ms), LED diagnostic indicators, factory calibration with trimming capability, and compliance to leading CE, EMC, and RoHS standards make it a find for discerning professionals. With modular DIN rail mounting and high output resolution (16 bits), it stands out in the market for superior performance and adaptability.

Applications, Features, and Usage Highlights

Trusted by professionals in industrial automation and process control systems, the EUROTHERM 2500M / AO2UNIV output module boasts high conversion efficiency and universal analog outputs. Frequently utilized in advanced factory setups, its configurable voltage and current outputs, quick response, and channel-to-channel isolation stand out. Removable terminal blocks and LED status indicators ease installation and monitoring. Designed for reliability, it finds use in manufacturing, energy management, and critical process environments where accuracy is paramount.


Payment Terms, Sample Policy, and Market Value

We prioritize seamless transport services for prompt and secure delivery of the EUROTHERM 2500M / AO2UNIV output module across India. Our payment terms are adapted to support varied business expenditures, offering flexibility through standard market value pricing. Samples are available; we maintain a transparent sample policy to provide hands-on product assessment prior to purchaseminimizing risk and helping customers make informed investment decisions.


FAQs of EUROTHERM 2500M / AO2UNIV / / XXXXX / XXXXXX / / / / OUTPUT MODULE:


Q: How can the EUROTHERM 2500M / AO2UNIV output module be configured for different analog output signals?

A: The module can be software-configured to provide a range of analog output signals, including voltage (0-10VDC, 2-10VDC, 10VDC) and current (0-20mA, 4-20mA) outputs, making it adaptable to various industrial applications.

Q: What benefits does channel-to-channel isolation offer in industrial automation?

A: Channel-to-channel isolation ensures reliable operation by preventing electrical interference between outputs, increasing safety and signal integrity in demanding process control environments.

Q: When is a sample of the EUROTHERM 2500M / AO2UNIV module available for evaluation?

A: Samples are available prior to purchase on request, following our transparent sample policy, allowing customers to assess performance and suitability for their applications before committing to expenditure.

Q: Where can the EUROTHERM 2500M / AO2UNIV output module be used?

A: It is designed for integration within industrial automation systems and process control setups. Applications include manufacturing plants, energy management systems, and any environment requiring precise analog signal output and monitoring.

Q: What is the process for addressing configuration in this output module?

A: Addressing is managed through software; users can configure both channel addresses and output types according to specific system requirements, adding flexibility and control for tailored automation solutions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in EUROTHERM Used PLC AC DRIVE DC DRIVE Category

EUROTHEREM T112

EUROTHEREM T112

Current Range : 016A

Material : ABS Plastic Body

Power Factor : >0.95

Noise Level : <40dB

Application : Industrial and Laboratory Temperature Control

Operating Temperature : 0C to 55C

EUROTHERM T170

EUROTHERM T170

Current Range : 420 mA Input Supported

Material : ABS Plastic

Power Factor : High

Noise Level : Low

Application : Industrial Automation, Process Control

Operating Temperature : 0C to 50C

EUROTHERM SERVO DRIVE

EUROTHERM SERVO DRIVE

Current Range : Rated 2A to 35A

Material : Die Cast Aluminium

Power Factor : >0.95

Noise Level : < 55 dB

Application : Industrial Automation, CNC Machines, Robotics

Operating Temperature : 0C to 50C

EUROTHERM  U17748-1-3-05-01

EUROTHERM U17748-1-3-05-01

Current Range : 10A 50A

Material : Metal Enclosure

Power Factor : 0.8 or Higher

Noise Level : Low

Application : Industrial Automation

Operating Temperature : 0C to 50C



Back to top