DANFOSS 130B6062 2\2 DT18 DRIVE BOARD Specification

  • Output Current
  • Max 37 A
  • Power Factor
  • >0.95
  • Working Temperature
  • -10C to +50C
  • Operating Temperature
  • -10C to +50C
  • Power Supply
  • AC Supply
  • Phase
  • Three Phase
  • Rated Power
  • 18 kW
  • Output Type
  • AC
  • Rated Current
  • 37 A
  • Application
  • Danfoss VLT Drives integration, industrial drive systems
  • Cooling Method
  • Open frame, air cooled
  • Current Range
  • 0-37 A
  • Features
  • Microprocessor controlled, Protective Conformal Coating, Fault Detection, Compact Design
  • Connector Type
  • Plug-in edge connectors
  • Noise Level
  • <65 dB
  • Product Type
  • Drive Board
  • Output Power
  • 18 kW
  • Output Frequency
  • 0-590 Hz
  • Input Voltage
  • 380-480 V AC
  • Voltage Protection
  • Over-voltage, Under-voltage Protection
  • Efficiency
  • Up to 98%
  • Material
  • Epoxy Coated PCB, Mixed Metals
  • Line Regulation
  • 1%
  • Storage Temperature
  • -25C to +70C
  • Weight
  • Approx. 0.7 kg
  • Protection Class
  • IP00
  • Mounting Type
  • PCB Mount
  • Humidity Range
  • 5% 95% RH non-condensing
  • Compatibility
  • VLT AutomationDrive FC302/FC301
  • Dimension
  • Approx. 210mm x 140mm
  • Control Method
  • PWM (Pulse Width Modulation)
  • Model Number
  • 130B6062 2/2 DT18
  • Isolation Voltage
  • 1500 V AC
 
 

About DANFOSS 130B6062 2\2 DT18 DRIVE BOARD



Ending Soon: Secure your place among elite operators with the sought-after DANFOSS 130B6062 2/2 DT18 DRIVE BOARD. Trusted for its classic performance and redoubtable reliability, this board boasts limited stock and is highly demanded for integration into VLT AutomationDrive FC302/FC301 systems. Featuring a compact, epoxy-coated PCB, the DT18 delivers up to 98% efficiency at a rated power of 18 kW. Enhanced with over-voltage and under-voltage protection, superior current control, and robust humidity resilience, its the first choice for industrial drive experts seeking premium quality.

Practical Usage and Application

The DANFOSS 130B6062 2/2 DT18 DRIVE BOARD is used for seamless integration with VLT AutomationDrive FC302/FC301, streamlining motor control for industrial drive systems. Direction of use involves PCB mounting and plug-in edge connectors, ensuring swift installation. This model is ideal for three-phase AC applications, offering precision PWM control, fault detection, and reliable output regulation.


Packaging and Order Information

Dispatching of the DANFOSS DT18 drive board comes with careful packaging to ensure safety during transit. Samples are available for qualifying requests, supporting your order evaluation. Estimate your delivery schedule based on efficient order processing, with multiple payment terms tailored for flexibility. Every order receives dedicated attention to meet both urgency and accuracy in fulfillment.


FAQs of DANFOSS 130B6062 2\2 DT18 DRIVE BOARD:


Q: How can the DANFOSS 130B6062 2/2 DT18 DRIVE BOARD be used in industrial environments?

A: This drive board is designed for integration with Danfoss VLT AutomationDrive FC302/FC301 systems to regulate three-phase AC motors in industrial applications, offering precise control and dependable operation.

Q: What benefits does the DT18 model offer when compared to standard drive boards?

A: The DT18 provides up to 98% efficiency, advanced fault detection, and humidity resilience, making it a sought-after choice for industrial automation where performance and reliability are paramount.

Q: Where can the DANFOSS 130B6062 2/2 DT18 DRIVE BOARD be mounted?

A: The board features a PCB mount design with plug-in edge connectors, allowing straightforward installation directly onto compatible drive units and control systems.

Q: What is the process for ordering and dispatching the DT18 drive board?

A: Orders are processed promptly, and the drive board is dispatched with secure packaging. Delivery estimates depend on order volume and location, and payment terms can be discussed for convenience.

Q: When is sample availability and testing support provided?

A: Sample units may be available upon request during order processing, giving buyers the opportunity to evaluate compatibility and performance before full-scale deployment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in DENFOSS Used AC DRIVE Category

Danfoss VLT TYPE 5002 175Z0041

Danfoss VLT TYPE 5002 175Z0041

Input Voltage : 380415V AC

Connector Type : Screw Terminal

Noise Level : <70 dB

Product Type : AC Drive (Variable Frequency Drive)

Storage Temperature : 25C to +65C

Features : Overload Protection, Compact Design, User Friendly Interface

DENFOSS 130B7002 AT,06

DENFOSS 130B7002 AT,06

Input Voltage : 230V AC

Connector Type : Standard

Noise Level : Low

Product Type : Electronic Controller Board

Storage Temperature : 20C to 70C

Features : Compact Design High Durability

Danfoss Frequency Converter-051P7K5T4E20H3BXCXXXSXXX

Danfoss Frequency Converter-051P7K5T4E20H3BXCXXXSXXX

Input Voltage : 380480 V AC

Connector Type : Terminal block

Noise Level : <68 dB(A)

Product Type : Frequency Converter

Storage Temperature : 25C to +65C

Features : Builtin EMC filter, LCD display, Programmable parameters

DENFOSS 130B6060 (2)

DENFOSS 130B6060 (2)

Input Voltage : 220V AC

Connector Type : Screw Terminal

Noise Level : Low

Product Type : Electronic Control Module

Storage Temperature : 20C to 70C

Features : Compact Design Reliable Performance