ABB REB500 RELAY
ABB REB500 RELAY
ABB REB500 RELAY
ABB REB500 RELAY
ABB REB500 RELAY
ABB REB500 RELAY

ABB REB500 RELAY

ABB REB500 RELAY Specification

  • Rated Current
  • 1 A or 5 A (busbar CT nominal)
  • Noise Level
  • < 55 dB
  • Phase
  • Three phase system compatible
  • Features
  • Distributed architecture, fast protection, modular, disturbance recorder, IEC 61850 protocol, self-supervision, event logging, HMI
  • Working Temperature
  • -10C to +55C
  • Cooling Method
  • Natural air cooling
  • Current Range
  • 1 A / 5 A nominal (CT input)
  • Output Type
  • Multiple digital and analog relay outputs
  • Power Supply
  • Redundant supply, 110-250 V DC / 100-230 V AC
  • Application
  • Substation busbar protection and automation
  • Operating Temperature
  • -10C to +55C
  • Connector Type
  • Plug-in terminal blocks (rear/front access)
  • Product Type
  • REB500 Centralized Busbar Protection Relay
  • Output Frequency
  • 50/60 Hz (system compatible)
  • Input Voltage
  • 110-250 V DC / 100-230 V AC (auxiliary supply)
  • Voltage Protection
  • Yes (Programmable limits)
  • Efficiency
  • High (designed for rapid and reliable protection events)
  • Material
  • Rugged metallic enclosure
  • Storage Temperature
  • -40C to +85C
  • Weight
  • Approx. 15 kg
  • Firmware Upgrade
  • Ethernet/serial software upgrade capability
  • Communication Protocols
  • IEC 61850, LON, SPA, IEC 60870-5-103, MODBUS
  • Compliance
  • IEC, ANSI, and regional standards
  • Disturbance Recorder
  • Built-in with up to 60 seconds per disturbance
  • Event Recording
  • Up to 2000 events with time stamping
  • Self-diagnostics
  • Continuous self-monitoring and supervision
  • LCD Display
  • Integrated front-panel display for local HMI access
  • Redundancy
  • Supports redundant power supply and communication
  • Mounting Type
  • Rack-mounted modular system
  • Input/Output Modules
  • Modular and field-expandable
  • Protection Functions
  • Phase segregation, zone selection, current differential, CT supervision
  • Relay Outputs
  • Configurable, potential-free contacts
 
 

About ABB REB500 RELAY



Shop Now for the ABB REB500 RELAY, a must-have solution for substation busbar protection and automation. Engineered with unassailable reliability, its modular rack-mounted system ensures kingly efficiency and rapid protection. Experience perfect control and distributed architecture, allowing seamless access via a comprehensive LCD display and multiple communication protocols including IEC 61850, LON, MODBUS, and more. Benefit from integrated event recording, advanced disturbance recorder, continuous self-diagnostics, and configurable relay outputs. Enjoy redundancy in power and communication, all housed in a rugged metallic enclosure. Unlock superior performance and robust compliance today.

Application Excellence for Substations and Utilities

ABB REB500 RELAY is designed for application in substations, power plants, and electrical utilities, delivering robust busbar protection and automation. Its distributed, modular architecture accommodates complex protection schemes, while field-expandable I/O modules adapt to evolving site requirements. With integrated HMI local access, it simplifies operations. Built-in redundancy and programmable voltage protection ensure reliability, making it the perfect choice for electrical networks requiring fast, secure, and scalable protection solutions.


Domestic Market, Port, and Certifications Insights

The main domestic market for the ABB REB500 RELAY includes India and neighboring regions, with leading demand driven by utility and power sector valuations. The typical sale price is determined by the system configuration, with FOB port options including Mumbai or Chennai. Certified under IEC and ANSI standards, this relay achieves high asking price due to its proven reliability and performance. Customers benefit from documented compliance and robust support across multiple market sectors.


FAQs of ABB REB500 RELAY:


Q: How does the ABB REB500 RELAY support busbar protection in substations?

A: The ABB REB500 RELAY utilizes fast protection functions such as phase segregation, current differential, and zone selection, ensuring prompt and reliable response to faults within substation busbars.

Q: What communication protocols can the ABB REB500 RELAY interface with?

A: The relay supports IEC 61850, LON, SPA, IEC 60870-5-103, and MODBUS protocols, enabling seamless integration into various automation and control systems.

Q: When is the firmware upgrade process performed on the ABB REB500 RELAY?

A: Firmware upgrades can be executed via Ethernet or serial connections, typically scheduled during maintenance intervals or system enhancements to ensure continued optimal performance.

Q: Where can operators access local HMI functions on the ABB REB500 RELAY?

A: Operators can access local HMI functions directly from the integrated LCD front-panel display, providing intuitive control and monitoring at the users fingertips.

Q: What benefits does event recording offer in the ABB REB500 RELAY?

A: Event recording stores up to 2000 event logs with time stamping, allowing precise fault analysis and system diagnostics, thereby improving maintenance and operational decisions.

Q: How does redundancy improve reliability in the ABB REB500 RELAY?

A: With dual power supply and redundant communication options, the relay maintains continuous operation and communication even in case of component failure, minimizing service interruptions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in RELAY Category

SIEMENS 7SJ8041-5EB20-1FC2/DD  PROTECTION RELAY

SIEMENS 7SJ8041-5EB20-1FC2/DD PROTECTION RELAY

Current Range : 1 A / 5 A (selectable)

Cooling Method : Selfcooled

Working Temperature : 25C to +70C

Features : Digital multifunctional relay, configurable inputs/outputs, integrated communication

Phase : Other, 3 Phase

Input Voltage : 24250 V AC/DC

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

GE DIGITAL ENERGY MULTILIN F650BABF2G1HI RELAY

Current Range : 1 A / 5 A nominal (configurable inputs)

Cooling Method : Natural air cooling

Working Temperature : 10C to +60C

Features : Feeder protection, advanced metering, event recording, waveform capture, IEC 61850/MODBUS/IEC 60870 protocol support, large graphic display, flexible configuration

Phase : Three Phase

Input Voltage : 24250 V AC/DC

SIEMENS 7SR1053-2LA21-2EA0/BB RELAY

SIEMENS 7SR1053-2LA21-2EA0/BB RELAY

Current Range : 1A/5A CT (Secondary current)

Cooling Method : Natural air cooling

Working Temperature : 10C to +55C

Features : Multifunction, Numerical, Disturbance recorder, Event recorder, Fault recorder, Communication Port, IEC61850 & MODBUS

Phase : Other, 3 Phase

Input Voltage : 24250 V AC/DC

SIEMENS 7SR1003-1KA20-2CA0/DD RELAY

SIEMENS 7SR1003-1KA20-2CA0/DD RELAY

Current Range : 1 A / 5 A

Cooling Method : Natural Air Cooled

Working Temperature : 25C to +55C

Features : LED Indications, User Programmable, Drawout Case, RS485 Communication

Phase : Other, 1 Phase / 3 Phase

Input Voltage : 24250 V AC/DC



Back to top